Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-Finance | L1 | Accepted-Finance Accepted financial bid | |
| 2 | L2₹25.7 L+₹1.7 L (7.06%)Accepted-Finance 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Accepted-Finance Accepted financial bid | |
| 3 | L3₹28.0 L+₹4.0 L (16.8%)Accepted-Finance | L3 | Accepted-Finance Accepted financial bid | |
| 4 | L4₹28.3 L+₹4.3 L (18.1%)Accepted-Finance 310 D KAMBAL WALA BAGH RAJWAHA ROAD NEW MANDI MUZAFFARNAGAR U P 251001 | MUZAFFARNAGAR | UTTAR PRADESH | 251001 | L4 | Accepted-Finance Accepted financial bid |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MES Roorkee
GE MES Roorkee 247667
Special Repair to Bldg No253 old foaling line at RTS depot Saharanpur under GE Roorkee
2022_MES_539330_1
8392/186/E8
Open Tender
Civil Works
Item Rate
180 days
Saharanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer MES Roorkee
₹78,000
Yes
30 Aug 2022
19 Jul 2022
23 Aug 2022
19 Jul 2022
16 Aug 2022
2 Aug 2022
Amount
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) using course sand confirming to IS 2116-1980 complete all as specified and directed.
All as per item No 2 above here in before but except bricks complete all as specified and directed. Note:- Serviciable bricks obtained from item No 1 shall be re-used.
Taking down cement or cement lime plaster from brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on external fair faces of brick/concrete work surfaces finished even and smooth (without using extra cement) including preparation of new plaster suraces of wall and applying three coats white wash complete all as specified and directed.
M & L for rendering 12mm thick on wall in CM 1:6 on other than fair faces of brick work or concrete surfaces and finished even and smoth without using extra cement including prepration of new plaster surfaces of wall and appyling three coats white wash complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in floor etc 100 mm thick finished even and smooth without using extra cement laid in alternate bays, with spike rolling to surfaces or making impression of expended metal whilst the concrete is green complete all as specifed and directed.
M & L PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
Dismantling asbestos cement corrugated or semi corrugated sheet in roof and removal from site for taking into schedule of credit complete all as specified and directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc, fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
Fixing only 6 mm thick asbestos cement corrugated or semi corrugated sheets in roofs, wall etc fixed with J- type or cranked hook bolts complete all as specified and directed. Note:- Serviciable sheets obtained from item No 10 shall be re-used.
S & F Fibre glass rainforced translucent corrugated sheeting with two corrugations side lap fixed with If fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
Dismantling of wrought Iron or mild steel work of any description not otherwise provided for such as wind ties, valley gutter, supports steel windown etc complete all as specified and directed.
M&L for factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. Note:- Design of window as per existing window or approved by Eng-in-Charge.
M&L for factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F framed work such as grills gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars barred iron doors, and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed.
S&F 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads glazing pins and putty in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36mm and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples, complete all as specified and directed .
S & F in repairs stainless steel wire cloth 0.36mm and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples, complete all as specified and directed .
Dismantling structural steel work including doors, gates purlins/ rafters but excluding framed truss etc, complete all as specified and directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. , complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for handing or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing Fe-290 (Gde E- 165) complete all as specified and directed.
S&F in repairs, 15mm bore GI tubing (ISI marked), medium grade with all fittings and fixed to walls and ceilling or laid in flooring including connection etc including taking down old tubing complete all as specified and directed.
S&F in repairs bib taps 15 mm bore, Bib taps, cast iron plug type with brass spindle confirming to relevent IS and fixed, complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick cement screed (1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish, including dismentling of old tiles with cement morter bedding and removing off the premises complete all as specified and directed.
M & L for kota stone slab 20-25 mm thick in skiring, etc over 15 mm cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish, including dismentling of old tiles with cement morter bedding and removing off the premises complete all l as specified and directed.
Taking down wooden/steel chowkhat or frame with shutters ( (without taking off shutters from the frame wooden/ steel) n.exc 1.5 Sqm complete all as specified and directed.
S&F Factory made 35 mm thick 2nd class H.W plain framed paneled shutters( two panel) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003(part I ) kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 35 mm thick 2nd class HW glazed skeleton shutter divided into square with plain chamfered or rounded with sash bars open rebated and prepared to receive glass/gauge etc. with plain chamfered rounded fitted with cut and mitred beads size of members of window, ventilator shutters, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24 (a) and fitted to chowkhat complete all as specified and directed .
S&F 100mm size mild steel butt hinges, ISI marked medium weight cold rolled, fixed to wooden chowkhat with screws or welded to steel frame complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section complete all as specified and directed.
S&F 150mm size aluminium alloy handles, cast type extruded section, ISI marked complete all as specified and directed.
S&F in repairs, mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F mild steel sliding door bolts,300 mm long plate type, stove enameled black with bright bolt not less than 12 mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple complete all as specified and directed.
M & L for 15mm thick 2nd class hard wood boarding, clean sawn with butt joints fixed with nails in any situation including dismentling of old unservicable boarding complete all as specified and directed.
M&L for preparing new or previously untreated wooden or wood based surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and Labour for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash complete all as specified and as directed.
Taking down old point wiring of any decription and M & L for Point wiring in repair with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement complete all as specified and directed for the following :- Note for Point wiring:- The quoted rate is deemed to be included rate of dismantling of existing point of any type including fittings & fixtures complete.
One light /fan point controlled by one, one way switch 5 Amp complete all as specified and directed.
One Ceiling/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
All as per item No 40.00 above but concealed wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable, green colour as earth continuity wire, for the 15 Amp 3/5 pin socket power point complete all as specified and directed.
Supply and fix switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
Supply and fix switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed.
Supply and fix socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
Supply and fix socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
S&F electronic fan regulator 230 volts , step type (5 step) socket type ,hum free 100/300 watt complete all as specified and directed.
S&F for Ceiling rose in poly carbonate 3 terminal brass flush type 6 Amps,250 volts AC ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F LED Tube light fitting 1x18/20 Watt surface and wall mounted LED batten, PVC housing with polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed . Make : Havells ENDURALINEARNEOBS20WLED830SPCWH or equivalent Phillips Smart Bright cat Part No. BN021CLED20SPSUCWGRS2
S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall including taking down carefully existing UNSV main switches, DBS along with MCBs complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve TPN/FP 100 Amp capcity in the DB complete with connection complete all as spd and directed.
S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts 200 amps rated busbar 8 way complete all as specified and directed.
S&F in replacement of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts 200 amps rated busbar 4 way complete all as specified and directed.
M&L for MCB single pole,6 to 32 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as spd and directed.
S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, including suitable size of copper thimble double pole 40 Amps, breaking capacity 10 KA complete all as spd and directed.
S & F Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 sqmm LT, 1100V grade, down through and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 4.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable and one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be include and shall not be measured separately. Earth wire shall run inside the conduit pipe including taking down old sub main wireing complete all as spd and directed. Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specifid and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 3.5 core including taking down of existing cable complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 sq mm 4 core including taking down of existing cable complete all as specified and directed.
Supply and lay in trench/floor/wall/hard standing GI pipe light grade 40 mm bore including its necessary fitting such as bends sockets etc for cable protection complete all as specified and directed.
Material and labour for river washed and screened dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
Supply & lay in trenches sub class `B’ bricks having compressive strength 75 Kg/ Sqcm for cable protection etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I CONTD....
and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) (chamber size not less than 300x300x300mm interier diamentions), type C-1 chamber, 50mm thick cover slab RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 10 cm c/c both way for cover and MS frame etc., complete all as specified. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. and chamber shall be made 0.5 mtr away from the earthing pit.
Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed.
M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with 40 x 5 MM -02Nos, size clamps bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primer all as specified and directed.
S&F LED in replacement light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as spd and directed.
S&F 20mm Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Concussive push button taps of cast Iron, screwed for iron pipe and fixed complete all as specified and directed.
Taking up steel tubing of the following bore sizess from trenches / floors or fixed to walls/ceiling including cleaning for re-fixing or removal from site complete all as specified and directed by Engineer-in-charge. Note:- Excavation & earth work shall be measured and paid for separately.
15mm dia bore
20 mm dia bore
S&F GI tubing of the following bore sizes, medium grade with all fittings and fixed to wall/ceiling or laid in floor/trenches complete al as specified and directed.
15mm dia bore
20 mm dia bore
M&L for refixing of old GI pipes of the following bore sizess with all fittings (old or new as per site requirement), laid in trenches/ floors or fixed to wall/ceiling complete al as specified and directed.
15mm dia bore
20 mm dia bore
Cuttng of existing GI pipe in position for inserting of tee, bend collar other type of GI fitting for addition /alternation of existing system for 40 mm bore complete all as spd and directed.
G.H. INFRASTRUCTURE PRIVATE LIMITED
Bharat Bhoomi Construction
BHAGAT JI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .