Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical non responsive |
Tender Value
₹4.2 L
EMD Value
₹8,460
Closing Date
29 Jul 2020, 2:00 pmClosed
DGM Unit electric Srinagar
DGM Unit electric Srinagar
Internal Electrification of Doctors Special Doctors Quarter at Sub District hospital Rajpora
2020_PWDJK_100929_1
30/E/K of 2020-21 Dt. 20.07.2020
Open Tender
Electrical Works
Item Rate
90 days
Rajpora
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
FC JKPCC Ltd A/c
₹8,460
Yes
DGM Unit electric Srinagar
7 Aug 2020
21 Jul 2020
30 Jul 2020
21 Jul 2020
29 Jul 2020
21 Jul 2020
25 Jul 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Excluding cost of pvc conduit)
Group A
Group B
Group C
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(Excluding cost of pvc conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Excluding cost of pvc conduit)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4X 10 sq. mm +2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
8 Module (125mm X 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply Installation, testing and commissioning of Ceiling fans 5 star rating complete with double ball bearig, motorbearing, blades,down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required '1200mm sweep
Supply,testing & commissioning of 900 RPM 300mm Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers, shutters etc complete as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double door
Supplying and fixing 5 A to 32 A rating single pole, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply,Installation of LED indoor recessed/ surface Downlighter suitable for general lighting.Luminarie should have CRCA body & poly carbonate cover with diffused optics.The luminarie should have CRI>80 and CCT of 3000K/4000k/6500K.The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 6 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C.The electronic driver used shall have a power factor>0.95,THD<10%.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics, IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0, 2007 for Electrical safety,IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009, CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground as required. 'Above 35 sq. mm and upto 95 sq. mm in ground 1 mt deep
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X95 sq. mm (35 mm)
3½ X70 sq. mm (35 mm)
Supply of multi core, stranded / solid aluminum conductor, XLPE / PVC insulated armoured, PVC outter sheathed 1100V, grade cables of the following sizes.
3.5c * 95sqmm Al, XLPE, arm
3.5c * 70sqmm Al, XLPE, arm
Design,fabrication,assembly,testing and commissioning of floor mounted, free standing, totally enclosed, indoor, cubicle, extendible compartmentalized, front operational,vertical,pest and vermin proof, Main LT panels/main distribution boards manufactured from 2.0mm thick CRCA sheet steel frame work and 1.6mm thick covers with hinged detachable, locable, front and back open able dual compartmentalized individual chamber door.3mm thick gland plates having gone through seven tank process of finishing, powder coated in required shade. (1 PHASE BUS)The bus bar shall be aluminum with DMC supports. The equipments shall be of the makes as called for in list of makes, other accessories like lift hooks, cable alleys, base, compartmentalization etc shall be as per design approved, earth bus of respective materials shall be provided as standard feature with incoming as 1 No. of 125 Amps TPN 36 KA MCCB. B). 0-440V, Voltmeter, VSS and 2A control fuses c). Phase indicating lights with fuses in R,Y,B colour. CT and Ammeter OUTGOING 08No’s of 63 amp DP MCB
Design,fabrication,assembly,testing and commissioning of floor mounted, free standing, totally enclosed, indoor, cubicle, extendible compartmentalized, front operational, vertical, pest and vermin proof, Main LT panels/main distribution boards manufactured from 2.0mm thick CRCA sheet steel frame work and 1.6mm thick covers with hinged detachable,locable,front and back open able dual compartmentalized individual chamber door.3mm thick gland plates having gone through seven tank process of finishing, powder coated in required shade. (1 PHASE BUS) The bus bar shall be aluminum with DMC supports. The equipments shall be of the makes as called for in list of makes, other accessories like lift hooks, cable alleys, base, compartmentalization etc shall be as per design approved, earth bus of respective materials shall be provided as standard feature with incoming as 1 No. of 100amps TPN 36 KA MCCB.B).0-440V, Voltmeter, VSS and 2A control fuses-c).Phase indicating lights with fuses in R,Y,B colour. CT Ammeter OUT GOING 04No’s of 63 amp DP MCB
N S ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .