Tender Value
₹3.9 L
EMD Value
₹4,900
Closing Date
9 Nov 2024, 9:00 amClosed
Area Engineer (EandM)
Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Burdwan, West Bengal-713346
Testing, calibration and repairing of protection relay of HT switch gear and Transformer at surface substation of Pit No. 2 for safe electrical operation and to comply DGMS violation under Pandaveswar Colliery
2024_ECL_320160_1
GM-PND/EandM/24-25/113/659 dated 28/10/2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Pandaveswar Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,900
29 Jan 2025
30 Oct 2024
11 Nov 2024
30 Oct 2024
9 Nov 2024
30 Oct 2024
30 Oct 2024 - 2 Nov 2024
Amount
Testing, calibration and repairing of protection relay of HT switch gear and Transformer at surface substation of Pit No. 2 for safe electrical operation and to comply DGMS violation under Pandaveswar Colliery. (Inclusive of EPF/CMPF)
Cost of testing by Megger insulation tester of following Transformer :- a) 500 KVA, 11KV/550V-440V- 1 No. b) 150 KVA, 11KV/433V – 1 No. c) 500 KVA, 11KV/440V- 1 No. d) 250 KVA, 11KV/550V- 1 No. e) 250 KVA, 11KV/433V- 1 No.
Cost of testing by High Voltage Pressure Test of following Transformer:- a) 500 KVA, 11KV/550V-440V- 1 No. b) 150 KVA, 11KV/433V – 1 No. c) 500 KVA, 11KV/440V- 1 No. d) 250 KVA, 11KV/550V- 1 No. e) 250 KVA, 11KV/433V- 1 No.
Cost of testing of Transformer oil by dissolved gas analysis Test, Acidity Test, Di-electric Test, Water content measurement slag contest of following Transformer :- a) 500 KVA, 11KV/550V-440V- 1 No. b) 150 KVA, 11KV/433V – 1 No. c) 500 KVA, 11KV/440V- 1 No. d) 250 KVA, 11KV/550V- 1 No. e) 250 KVA, 11KV/433V- 1 No.
Cost of testing by Megger insulation testing of following Switch gear:- a) 11KV V.C.B. - 5 Nos.
Cost of testing by high voltage pressure testing of following Switch gear: - a) 11KV V.C.B. - 5 Nos.
Cost of repairing, testing & calibration of IDMT (2 Nos. over current & 1no earth fault relay) relay by secondary current injection Test set including supply of necessary spares in place of damaged spares.
Cost of repairing, testing & calibration of Earth leakage relay by secondary current injection Test set including supply of necessary spares in place of damaged spares.
Cost of Testing of Current Transformer (C.T.) by Primary Injection kit.
Overhead & Profit
Cost of both side Transportation with handling & loading & unloading charges.
Total impact of GST for the purpose of CTC
ELECTRO POWER INDUSTRIES (BID ID -1099377)
JUBILEE ELECTROMECH WORKS (BID ID -1099808)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .