Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
17 Aug 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MEERUT
130 D PAARESHAN BHAWAN VICTORIA PARK MEERUT
WORK TENDER
2020_UPTCL_494137_2
T-57/20-21/ETC/MT
Open Tender
Electrical Works
Item Rate
90 days
MEERUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
SE ETC MEERUT
₹22,000
26 Aug 2020
7 Aug 2020
18 Aug 2020
7 Aug 2020
17 Aug 2020
7 Aug 2020
90 days
Amount
DISMENTALLING
Dismantling of following equipment, structures, jumper, bus bar after opening of cables, earthing of 33 KV 10 MVAR capacitor bank and storing at proper place as per direction of supervising Engineer.
Capacitor bank and its associated bay jumpers
33 KV jack bus all 3 phase of approx length 18 meter.
Steel Structure.
33 KV Circuit Breaker.
33 KV Current Transformer/NCT/PT
33 KV bus/ line isolator.
Series Reactor.
Capacitor cells along with its structure(1X5 MVAR)
Erection of Sub-Station Structures
Sorting and stacking of structures
Erection of Main & Auxiliary structure lattic type ATM, BTM, BCT, ALP etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of CTs, PTs, LAs, etc. The job consist of shifting of all material from store to site of erection, erection of structure as per drawing with the help of GI nut & bolt, flat & spring washer, matching the hole, cutting & matching of member if required including cost of all men and T & P excluding GI structure Nut & bolt to complete the work. Erection of Main & Auxiliary structure lattice type BCT, ALP etc. upon foundation and its proper tightening.
Making hole in part of GI main/auxiliary structure / cutting of GI angle drilling of hole existing/ defective structure /plate/Angle and grinding machine with all cost of men, T & P etc.
Erection of following Equipments/Panels as per technical specification, manual and instruction as per direction of supervising engineer.
145 KV SF-6 Circuit Breaker.
145 KV Current Transformer.
145 KV Bus Isolator.
145 KV Tandam Isolator.
145 KV Post Insulator for support.
120 KV Lighting Arrestors.
Erection and mounting of 145 KV CT Junction Box.
33 KV Vacuum Circuit Breaker
33 KV Current Transformer/NCT/PT
33 KV Bus Isolator.
33 KV Lighting Arrestors.
33 KV Line Isolator.
33 KV Bus Post Insulator.
Erection and mounting of 36 KV CT Junction Box.
132 KV 40 MVA Control & Relay Panel.
Series Reactor.
Capacitor cells along with its structure and post insulator (1X5 MVAR)
Earthing work.
Fabrication of 3 Meter long electrodes with 40 mm dia MS round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Station to switchyard.
Delta earthing of 120 KV / 33 KV LAs and neutral of Transformer by 40 mm dia 150 mm long conical shape its placing inside the ground in rectangular shape and connecting all 3/6 Nos. electrodes with 75x10/50x6 mm MS flat laid on its edge and then this rectangle/triangle shape strictly as per drawing.
120 KV LA (Rectangle shape by 06 electrodes) with 40 mm dia round bar.
40 MVA Transformer (Triangular shape by 03 electrodes) with 40 mm dia round bar.
33 KV LA (Rectangle shape by 04 electrodes) with 40 mm dia round bar.
Earthing of equipments by cutting straightening, bending, laying 700 mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure equipments structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed, excavation of trenches, its back filling, to complete the work.
Laying MS Flat of size 75x10 mm
Laying MS Flat of size 50x6 mm
Laying MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Bus Bar Stringing and Jumpering.
Opening of jumpers of various 33 KV bay from 33 Main bus bar and 33 KV LA & PT.
Dismantling of 33 KV Main Bus Bar of single ACSR Moose conductor per phase along with its fitting, insulator etc.
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men T & P to complete the work.
Cleaning of disc insulator of 132 KV string.
Cleaning of disc insulator of 33 KV string.
Stringing of various Single phase Jack Bus of 220 KV, 132 KV and 33 KV with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, fixing of single/ double bolted type tension fitting/suspension. Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Jack Bus for 40 MVA Transformer Bay for Panther conductor.
33 KV Main Bus of twin ACSR Moose conductor and also providing spacers.
33 KV Jack Bus for capacitor bank for Panther conductor.
Hoisting of 132 KV string under Beam to pass the jumper including hanging of disc insulator and suspension fitting complete with all work.
Jumpering, interconnection of equipment with specified conductor of various 132/33 KV equipments with Main/Transfer/Jack Bus Bar of ACC Tarantula / ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shape, clamping with the help of clamps and all other associated work to complete the work.
132 KV 40 MVA Transformer Bay.
33 KV Capacitor bank Bay.
33 KV side 40 MVA Transformer LV side of Twin Moose conductor.
Providing jumpers for various 33 KV bay from main bus to bus isolator twin Panther conductor.
33 KV LA/PT from Panther conductor.
Cable Laying and Termination work.
Laying & Termination of following size control cable in trench/cable trays from different control room equipments to 220/132/33 KV CB, CT, CVT and their junction boxes. Transformer marshalling box, isolator box and other outdoor equipments installed in 132 KV switchyard as per cable schedule including carriage of cable drum from store and all other associated work.
2 Core x 2.5mm2
4 Core x 2.5mm2
6 Core x 2.5mm2
Termination of control cable.
Erection of 40 MVA 132/33 KV Transformer.
Shifting of main tank of 40 MVA Transformer from unloading place to foundation distance about 20 Mtr.
Additional Shifting 100 Mtr. (part of 5 Mtr.).
Shifting and placing of accessories as radiator, conservator tank and other associated material from store to near Transformer plinth.
Filling the Transformer oil from oil drum to oil tanker and its centrifuging up to required BDV and creating the vacuum inside the main tank filling of Transformer oil in main tank.
Complete erection of 40 MVA Transformer and accessories HV/LV/TV/N bushing, Radiators, conservator tank., a frame, Header, oil pipe line, pump cooling fan etc. to top up required level.
Centrifuging the transformer oil in Main tank and circulate the Transformer oil through centrifuging machine and taking BDV time to time.(18 KL)
Supply portion :-
Bolted type single Tension fitting for Panther Conductor suitable for 1x10 No Disc insulator without buckle and hardware set as per technical specification.
Bolted Type single tension fitting for twin moose conductor suitable for 1x4 No Disc insulator without buckle and hardware set as per technical specification.
Bolted type single Tension fitting for Panther Conductor suitable for 1x4 No Disc insulator without buckle and hardware set as per technical specification.
Bolted type single suspension fitting for single Panther Conductor suitable for 1x10 No Disc insulator with hardware set as per technical specification.
3 Bolted Type PG clamp suitable for Panther to Panther conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG Clamp suitable for Moose to Moose conductor complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG Clamp suitable for Moose to Panther conductor complete with HDG nut bolt & washer as per technical specification.
132 KV Bus Post clamp suitable for Panther conductor complete with hot dip galvanized nut bolts & washer as per technical specification.
33 KV Bus Post clamp suitable for Twin Panther conductor complete with hot dip galvanized nut bolts & washer as per technical specification.
Bimetallic terminal connector for 40 MVA T/F HV side bushing rod 30 mm dia made of aluminum alloy LM-6 suitable for ACSR single Panther conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
Bimetallic terminal connector for 40 MVA T/F LV side bushing rod 30 mm dia made of aluminum alloy LM-6 suitable for ACSR Twin Zebra conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
Spacer for Twin Moose bundle conductor for 250 mm spacing as per technical specification.
GI Nut, Bolt and washer of different sizes
Bimetallic 33 KV Isolator clamp for ASCR Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV Circuit Breaker clamp suitable for ACSR Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV CT clamp suitable for ACSR Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Supply of cable gland of different sizes.
i- 2C x 2.5 mm2 (16mm)
ii- 4C x 2.5 mm2 (19mm)
iii-6C x 2.5 mm2 (22mm)
Supply of copper lug of different types.
i- Ring type of size 2.5 mm
ii- Pin type of size 2.5 mm
Providing & fixing new generation energy saving & environment friendly long life versatile pressure die-cast aluminium outdoor high beam flood light with power 120 W LED as light source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 Volt AC input supply of IS make of CGL/ hevells /Surya/ Philips/ Bajaj etc. brand.
Laying dressing & termination of control cable for the gantry light with the help of clamps vertically on the Gantry & all other associated work required for completion of work.
Providing & fixing of junction box of 16 SWG MS sheet duly painted size 150x150x200 mm for the above light on the bottom of main structure with the help of clamps. Junction box contains 01 no.05 amp single pole MCB (L&T, hevells, Siemens make) with 01 no link as per technical specification.
SUN ENGINEERING WORKS
SHIVAM ENGINEERS
Versha and Brothers
Reliance Enterprises
M/s S.S. Refregeration
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .