Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.6 LRejected-Finance | 1 | Rejected-Finance QUOTED BID PRICE IS 10.33 PERCENT HIGHER THAN THE APPROVED DNIT. |
Tender Value
₹5.0 L
EMD Value
₹10,100
Closing Date
4 Apr 2022, 5:00 pmClosed
EXECUTIVE ENGINEER, W/S AND SANITATION DIV BARNALA
W/S AND SANITATION DIVISION BARNALA, NEAR COURT CHOWK, BARNALA
Repair of Pump Chamber, Pumping Machinery, New HH Connections and Repair of Existing Connections, Laying Pipeline and other works as per DNIT at VILLAGE JAGJITPURA
2022_WB_82929_1
WSSD/Barnala/2021-22/39
Open Tender
Civil Works - Water Works
Item Rate
90 days
VILLAGE JAGJITPURA
Please Refer Tender Documents
5 documents required · 5 mandatory
₹1
₹10,100
28 Jul 2022
22 Mar 2022
5 Apr 2022
22 Mar 2022
4 Apr 2022
22 Mar 2022
Amount
Repair of Pump Chamber
Distempering with dry distemper of approved manufacture one coat on old distempered work as per CSR 16.8
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. as per CSR 16.16
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. as per CSR 16.18
Scraping of White washing inside of Pump Chamber & Scraping of snowcem robbiacem etc as per CSR 8.31 (a)
White washing 2 coats inside of pump chamber. as per CSR 16.2
Finishing walls with exterior decorative cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade. as per CSR 16.13
Supplying & fixing glass panes including special metal sash putty of approved make. as per CSR 18.25(b)
Providing, Laying fixing & jointing of PVC pipes as per ISI-4985 (ISI marked with the prior approval of Engineer in charge) along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications for more than 3 mtr street width including excavation & back filling complete in all respects as per Analysis-14A as per CSR 28.13
PVC pipe 63 mm o/d 6Kg sqcm
PVC pipe 110 mm o/d 6Kg sqcm
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Connection of existing PVC/AC (All dia) pipe with new PVC (All dia) pipe including cost of PVC/AC tee, D-joint ,PVC saddle piece, earth work in excavation & back filling etc complete in all respects as per PWD Sepcification/Satisfaction of Engineer in charge .
Providing water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class as per CSR 28.36 (A),( Above GL), Prov. & fixing MDPE pipe 20 mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects as per site condition
Improvment of old water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class as per CSR 28.36 (A),( Above GL), Prov. & fixing MDPE pipe 20 mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects as per site condition
Providing, installing, testing & commissioning one no. Electrically actuated, diaphragm operated, Metering system, chemical dosing Chlorinator, suitable for delivering 0.5 to 0.6 litres of bleaching powder solution/ sodium hypo solution per hour under maximum delivering pressure upto 7 kg cm^2 and suction lift not less than 1.5m as per DWSS standard Specification.
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 275 LPM against a head of 76.00 mtr (10.00 BHP) along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including M.S. Column Pipe of suitable size 80 mm =54 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 4.00 mm^2 (reputed make) = 120 mtr complete in all respects as per standard Specifications.
DEVELOPMENT OF HEAD WORKS SITE
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
Repair of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-3.
Repair of masonry gate pillar Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects
12.5 mm thick cement plaster 1:5 on wall as per CSR 15.10
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shadeats as per CSR 16.13
Repair of foot paths concrete topping ( Cement concrete 1:8:16 With stone aggregates 40mm gauge) inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects.
Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type as per CSR 10.6(b) (ii)
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material as per CSR 14.6
Painting of MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
Less Credit of Old Machinary ,Electrical Control Panel Board including Delivery
PART-B (O & M) For 3 Month
Providing Bleaching Powder Solution/ Sodium Hypo Solution complete in all respects
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .