Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.2 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹18.1 L+₹93,211 (5.43%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹18.9 L+₹1.7 L (9.89%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹19.2 L+₹2.0 L (11.8%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹19.5 L+₹2.4 L (13.8%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
UPKEEP AND MAINT OF SEWAGE SYSTEM AND CLEANING OF SEWAGE LINE ETC UNDER AGE B R I PATIALA
2021_MES_451861_1
GE(N)/PAT-25/2021-22
Open Tender
Civil Works
Item Rate
330 days
PATIALA
AS PER NIT DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NORTH PATIALA
₹36,000
Yes
3 Aug 2021
16 Jun 2021
9 Jul 2021
16 Jun 2021
7 Jul 2021
30 Jun 2021
60 days
Amount
Cleaning of sludge under ground sewage network including manholes obstruction free by removing any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed.
Note:- (i) Sewage network under new cantt area consists various dia of pipe lines varying from 10mm dia to 450mm dia. (ii) Contractor or his rep will report daily at complaint cell of old cantt at 9.00 AM for collection of complaints from the concerned JE's Incharge, on failure a penalty of Rs. 500/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office. (iii) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.100/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor. (iv) In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding. (v) During cleaning of deep manholes or pipe lines, for precautions, contractor will also arrange oxyzen cylinder of suitable size, rope/chain to the workmen and cost there of shall be included nnder this item.
Cleaning the sewage soakage pips, septic tanks of any dia depth and in any location etc by taking out complete sludge water and solids mechanically by HCV mounted suction discharge machine having flow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge. Note : Depth of sludge in the pit shall be measured from the bottom of pit to the existing water/effluent lever prior to ordering the cleaning in the presence of EIC.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and directed Engineer-in-Charge
All as per Serial items No. 3 herein before but exceeding 1.5 Mtr and not exceeding 3.00 Mtr depth complete all as specified and directed Engineer-in-Charge Note :- The rate quoted should include provision of oxygen cylinder , safety belts and helmet in case of deep earth work as and when necessary.
Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed Engineer-in-Charge
Brick work using Sub Class "B" brick, disignanation 100, straight or curved on plan not exceeding 6 Mtr means radius built in CM 1:4 complete all specified and directed by Engineer-in-Charge
All as per item no 06 herein above but for old Bricks complete all as specified and directed Engineer-in-Charge
Cement plaster 15mm thick on fair faces of brick wk in cement mortar 1:4 and finished even and smooth without using extra cement with/without WPC complete all as specified and directed by Engr-in-Charge (WPC where required shall be measured and paid separately)
Supply only integral water proofing compound of approved quality complete
Cement concrete (1:2:4) type B-1 using 20mm graded machnically crushed stone agg as in benching of manholes coping plinth course bands stops etc incl necessary form works complete all specified and directed by Engineer-in-Charges
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 150mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 200mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
Reinforced concrete pipes of 150mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
Reinforced concrete pipes of 200 mmdia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
Reinforced concrete pipes of 300 mmdia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manholes complete all as specified and directed
RCC (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in precast slabs for covers of manholes and set in CM 1:6 incl necessary from work hand placing of manhole cover on varsion complete all as specified and directed by Engineer-in-Charge
TMT bars 8mm dia and over cut to length bent to shape required incl cranking bending, spirally , hooking ends and binding with mild steel wire not less than 0.9mm dia (annealed) complete all as specified and as directed by Engineer-in-Charge. (Note : The payment shall be made only after placing of cover on manholes)
Returning and filling incl spreading, levelling, water and well ramming in layers not exceeding 25cm thick complete all as specified and directed Engr-in-charge
Demolition of reinforced cement concrete of any description and in any position complete all as specified
Removal of excavated material n. exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and formingbranch channel (1/2 round or 3/4section) in cement concrete 1:2:4 mix type B-1smooth finished and reforming benching as required of 150mm dia of pipe
Cast iron Nahani trap 100 mm dia with long arm n less than 450mm grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
Cast iron soil, waste and vent pipe, 100mm bore, sand cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete all as specified after taking down of existing unserviceable pipe fixed in repair
Cast iron soil, waste and vent pipe, 75mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections, fixed as in repair complete all as specified
S&F holder battern clamp 100 mm dia of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof
M&L for use and waste of timbering as planking and strutting for excavations exc 1.50m deep and n exc 3.00 m deep in shafts, wells, cesspits, manholes and pier holes as may be necessary and fixing and removal
AR CONSTRUCTIONS
Buttar Construction Co.
HG construction
m/s panchmukhi builders
M/s Rakesh Singla
KG BUILDERS
Jagdish kumar aggarwal
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .