| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹48.0 L+₹7.0 L (17.1%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹49.9 L+₹8.9 L (21.8%)Rejected-Finance MAHANANDA PARA GOVT SAW MILL ROAD P O SILIGURI DIST JALPAIGURI WB | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹50.3 L+₹9.4 L (22.8%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹50.5 L+₹9.5 L (23.2%)Rejected-Finance 45 9 6 BAGHAJATIN COLONY PO PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING WB | 734403 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Sept 2024, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR MAINT OF CERTAIN UG CABLE FEEDER PILLAR BOX AND ALLIED WORKS AT SUKNA UNDER GE SUKNA
2024_MES_669604_1
GE Sukna/8702
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹0
₹96,000
Yes
22 Dec 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
2 Sept 2024 - 23 Sept 2024
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
All as per item No. 1.00 above but depth exc 1.50 m and not exc 3 m.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/loose soil in layers, at site complete all as specified and directed
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note : For the purpose of payment only punned thickness will be measured.
M&L for Brick protection cover of size 230x115x75 mm to LT underground cables with sub class 'B' over burnt brick, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
M&L Plain cement concrete 1:2:4, type B-1( using 20mm graded crushed stone aggregate ) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of pole / strut etc including necessary form work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of GI tubing light grade 80mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete all as specified and directed .
Supply and fixing in repair of GI tubing light grade 50mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete all as specified and directed .
Supply and fixing in repair of GI tubing light grade 40mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete all as specified and directed .
Boring / Drilling (horizontally) manually under min 0.5 to 2 m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
M&L for laying of DWC (Double wall corrugated) PE cable duct pipes of size 50 mm outer dia for protection of HT/LT cables conforming to the IS:16205 type 450(450N) orange in color,including sockets/bends or any joints etc complete all as specified and as directed. Note:-Excavation will be measured and paid separately.
M&L for laying of DWC (Double wall corrugated) PE cable duct pipes of size 63 mm outer dia for protection of HT/LT cables conforming to the IS:16205 type 450(450N) orange in color,including sockets/bends or any joints etc complete all as specified and as directed. Note:-Excavation will be measured and paid separately.
M&L for laying of DWC (Double wall corrugated) PE cable duct pipes of size 90 mm outer dia for protection of HT/LT cables conforming to the IS:16205 type 450(450N) orange in color,including sockets/bends or any joints etc complete all as specified and as directed. Note:-Excavation will be measured and paid separately.
M&L for laying of DWC (Double wall corrugated) PE cable duct pipes of size 120 mm outer dia for protection of HT/LT cables conforming to the IS:16205 type 450(450N) orange in color,including sockets/bends or any joints etc complete all as specified and as directed. Note:-Excavation will be measured and paid separately.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc.connected to LT panel/poles with cable glands & lugs including taking down old unsv cable from trennches/ducts/floors/poles complete all as specified and directed of following sizes:- (Note: Excavation and earth work will be measured & paid separately)
240 sqmm 3.50 core
185 sqmm 3.50 core
150 sqmm 3.50 core
95 sqmm 3.50 core
70 sqmm 3.50 core
50 sqmm 3.50 core
35 sqmm 3.50 core
25 sqmm 4 core
16 sqmm 4 core
10 sqmm 4 core
10 sqmm 2 core
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or broken boulders complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-2,1:3:6 (40 mm graded aggregate ) as in sub base complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade complete all as specified and as directed.
M&L for Sand filling under interlocking paver block, floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded aggregate as in coping and the like including weathering ,slightly rounded or chamfered angles and throating complete all as specified and directed.
Dismantling of insulator of any size/type and setting aside the serviceable insulator for reuse at site and removing unserviceable insulators from site of work complete all as directed.
Supply & fix insulator pin type porcelain , vitreous , white ,brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 Volts grade complete all as specified and directed.
Supply & fix single Disc assembly insulator for tension with tension clamps to the conductors porcelain type , vitreous , white ,brown or green 145 mm height and 255 mm dia ball and socket type, working pressure 11000 Volts grade complete all as specified and directed.
Dismantling of Stay assembly embedded in concrete including demolition of concrete, etc and removing unserviceable materials from site of work complete all as directed by Engr-in-charge.
M&L for Stay assembly complete comprising of MS galvanised stay plate 230 mm x 230 mm x 6mm , MS galvanised stay rod 20 mm dia with nut, 215 M long , MS galvanised stay bow 40 cm long with 02 Nos galvanised thimbles with and including all fittings as shown in electrical plate No 1 of SSR Part-I (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed.
S&F galvanised stay strand 7/3.15 mm for stay of poles complete all as specified and directed.
M&L for loop porcelain ,vitreous white , brown or green insulator with over all dimension of 65 mm x 90 mm ,clearence of whole 25.5 mm complete all as specifeid and as directed. .
Supply and fixing in repair Switch air break, gang operated triple pole mechanically operated mounted on with 9 insulator and steel frame with operating mechanism working from ground level current rating upto 400A, 11000 V grade having nine insulators, vertical type including dismantling of existing air break gang operated switch and removal the same from site complete all as specified and directed.
Supply and fixing in repair expulsion drop out fuse carrier assembly outdoor type 400 Amps capacity including fuse element up to 60 Amps and insulator suitable for HT 11 KV complete and dismantling of existing fuse carrier assembly and removal the same from site complete all as specified and as directed.
Supply and fix in replacement of lightening arrester station type rated frequency 50 Hz nominal discharge current 65 kA and suitable for 11 KV complete all as specified and as directed.
Repair / servicing to gang operating devices 11000 volts up to 400 amps including greasing all the moving parts and applying white petroleum jelly at the contact points including dismantling and replacing all the un-serviceable parts/spares all as directed. Note:- All the spares replaced will be measured and paid separately under respective items of Schedule 'A'.
Dismantling of steel poles/struts any size embedded in concrete including demolition of concrete, etc and removing unserviceable materials from site of work complete all as directed by Engr-in-charge.
Supply, transportation, fixing and erection of steel tubular sewaged pole 9 mtr long complete with MS base plate ,finial taper plug nut bolts,screws as specified type 410 SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer and including making alternate red and black strips 30 cm height (Total 5 Nos ) and removing the old U/S one complete all as specified and directed. Note :- (Excavation and PCC will be measured and paid seprately.)
All as per item No. 36.00 above but 410 SP-55 type (11.0 metres long)
Supply fabricate, fixing structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed .
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV at the gap of 2.5 mm and refilling the same all as specified and directed by Engineer-in-Charge.Note:-(a) Dehydration plant to be brought at site by the contractor. (b)Dehydration and filteration to be carried out when the transformer is on load at site and rate quoted shall deemed to be included the cost of arrangement of plant by the contractor and its transportation at site complete all as specified and directed.
Supply and topping up / filling of fresh transformer oil conforming to ISD-335/BS of dielectric strength 50 KV at the gap of 2.5 mm minimum for transformer complete all as specified and directed by Engineer-in-charge.
S&F in repair of MCCB,100 Amps 16kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In all as specified and directed by Engineer-in- Charge.
S&F in repair of MCCB,160 Amps 25kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In complete all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB,200 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release complete all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB,250 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release complete all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB,400 Amps 36kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release complete all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB,630 Amps 50kA, four pole, 415 volt adjustable overload setting 0.8-1.0 x In and adjustable thermal & Magnetic release complete all as specified and directed by Engineer-in- Charge.
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 10 to 35 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed.
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 50 to 95 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed.
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 120 to 240 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed.
Cutting tree branches, any girth, below, top and around the LT/HT OH line and clearing not less than two mtrs around the line and keeping the line clearance through out the contract period by trimming the branches repeatedly as many as times required depending on the growth of new branches including clearing the site by depositing the branches to a distance not exceeding 50 m all as directed by Engr-in - Charge.
Supply & fixing copper alloy moving contact blades and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
Supply &Fixing copper alloy contact jaw and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
Supply & fixing Tinned copper flexible jumper and taking down unserviceable complete all as specified and directed by Engineer-in- Charge.
M&L for Jumper connection between OH line to GOD and GOD to drop out fuses with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required/aluminum heavy duty PG clamps contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm complete all as specified and directed.
Supply and replacement of dry silica gel with transparent jar to the transformers of capacity 25 KVA to 100 KVA after taking out the existing fully moisturized silica jell complete all as specified and directed.
Supply and replacement of dry silica gel with transparent jar to the transformers of capacity 160 KVA to 315 KVA after taking out the existing fully moisturized silica jell complete all as specified and directed.
Supply and replacement of dry silica gel with transparent jar to the transformers of capacity 400 KVA to 630 KVA after taking out the existing fully moisturized silica jell complete all as specified and directed.
M& L for on site repair of front and rear doors LT Panel of size 500mm x 500mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 1000mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 1200mm x 800mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 1500mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M& L for on site repair of front and rear doors LT Panel of size 2000mm x 1000mmx500mm including welding of butt hinges 06 Nos on front side and as per requirement on back side, aldrop latches on front and rear side,spray painting with synthetic enamel paint (one coat) complete all as specified and as directed
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized iron wire 4 mm dia as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI strip 25x4 mm complete all as specified and directed
S&F in repairs of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and as directed.
M&L for in replacement anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately) complete all specified and as directed.
S&F of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm including taking down old unsv complete all as specified and as directed.
All as per item No. 68.00 above but for aluminium conductor cable of size 120 to 150 sqmm including taking down old unsv complete all as specified and as directed.
S&F of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm including taking down old unsv complete all as specified and as directed.
All as per item No. 70.00 above but for aluminium conductor cable of size 120 to 150 sqmm including taking down old unsv complete all as specified and as directed.
S&F of LT 1100 Volt heat shrinkable straight through jointing kit for XLPE cable with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm including taking down old unsv complete all as specified and as directed.
All as per item No. 72.00 above but for aluminium conductor cable of size 70 to 120 sqmm including taking down old unsv complete all as specified and as directed.
All as per item No. 72.00 above for aluminium conductor cable of size 150 to 185 sqmm including taking down old unsv complete all as specified and as directed.
All as per item No. 72.00 above for aluminium conductor cable of size 240 to 300 sqmm including taking down old unsv complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
S&F in repair of Street Light Timer switch with 24 Hour daily setting, protected with IP-53 box, 230 volt,50Hz AC,ON-AUTO-OFF on front panel, one segment of 15 Min with accuracy of +/- 5 mins,complete all as specified and directed. Make:- Legrand Cat Part No 4127 90/Schneider/Havells
Dismantling and taking down old unserviceable LT panel board and Supply, installation, testing and commissioning of Panel board not less than 1.50m x 1.0 m x0.60 m, outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
INCOMING :- (a) Aluminium busbar 600 Amps rated capacity-04 Nos. (b) MCCB 400 Amps, 4 pole, 415 volt, 36 KA thermal &magnetic release adjestable type - 01 No (c) Spreader Link -01 No OUTGOING :- (a) MCCB 200 Amps, 4 pole, 415 volt 25 kA thermal &magnetic release adjestable type - 01 Nos (b) MCCB 100 Amps, 4 pole, 415 volt 16 kA thermal &magnetic release adjestable type - 02 Nos (c) Spreader Link -03 No (d) MCB TPN 63 Amps,415 Volt 'B' curve -03 Nos (e) MCB 6 Amps, 415 Volt, 'B' curve -01 No (f) Changeover switch open execution and extended handle 200 Amps 4 pole,415 Volt AC & inbuilt 2 CO auxiliary contact -01 No (g) Indication lamp Neon/ LED type (set of three) - 01 Set (h) Danger Notice plate - 01 No. (j) Panel control wiring complete with suitable size copper wire - 01Job.
Dismantling and taking down old unserviceable LT panel board and Supply, installation, testing and commissioning of Panel board not less than 1.0m x 0.8 m x0.60 m, outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :-
INCOMING :- (a) Aluminium busbar 400 Amps rated capacity-04 Nos. (b) MCCB 250 Amps, 4 pole, 415 volt, 25 KA thermal &magnetic release adjestable type - 01 No (c) Spreader Link -01 No OUTGOING :- (a) MCCB 200 Amps, 4 pole, 415 volt 25 kA thermal &magnetic release adjestable type - 01 Nos (b) MCCB 100 Amps, 4 pole, 415 volt 16 kA thermal &magnetic release adjestable type - 02 Nos (c) Spreader Link -03 No (d) MCB TPN 63 Amps,415 Volt 'B' curve -02 Nos (e) MCB 6 Amps, 415 Volt, 'B' curve -01 No (f) Indication lamp Neon/ LED type (set of three) - 01 Set (g) Danger Notice plate - 01 No. (h) Panel control wiring complete with suitable size copper wire - 01Job.
SHRI N.DAS (BID ID -3107993)
S GUHA (BID ID -3107768)
MS ORIENT ENGINEERING WORKS (BID ID -3105446)
Jagatbandhu Enterprises (BID ID -3105368)
PS ENTERPRISE (BID ID -3105507)
KARMIBRINDA (BID ID -3105961)
D K SARKAR (BID ID -3103038)
M/s TRIMURTI ASSOCIATE (BID ID -3102973)
R N SAH N CO (BID ID -3103234)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .