| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹37.0 L+₹3.3 L (9.85%)Rejected-AOC 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹39.7 L+₹6.0 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹41 L
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I R nd D WEST BANGALORE
GARRISON ENGINEER I R nd D WEST BANGALORE, DRDO PHASE-1, CV RAMAN NAGAR, BANGALORE-93
PROVISION OF INFRASTRUCTURE FOR PROJECT CAIR 072 AT CAIR BANGLORE
2024_MES_638698_1
GE(I)/R ND D/BAN/TOKEN/99 OF 2023-24 8254/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER I R nd D WEST BANGALORE
CLASS AND CATEGORY AS PER NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I R nd D WEST BANGALORE
16 Mar 2024
31 Jan 2024
6 Mar 2024
1 Feb 2024
29 Feb 2024
16 Feb 2024
1 Feb 2024 - 15 Feb 2024
Amount
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for doors, windows, ventilators and partitions in fixed position with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be measured and paid for separately) :
Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides, flat pressed, three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per directions of Engineer-in-charge.
Providing and fixing float glass panes of 5.0 mm thickness (weight not less than 10kg/sqm) as glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per directions of Engineer-in-charge. (Aluminium snap beading shall be paid under item no 1 above )
S&F Venetian blinds, rolling to the top type, 100 mm wide with polyester fabric of approved colour and pattern with aluminum fittings, and top rail and nylon buttons / loops etc., fixed cuttings and alteration if necessary wherever AC / coolers exists including dismantling of old unserviceable venetian blinds, complete all as specified and as directed.
Providing and fixing partition 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of Engineer in charge all complete.
Modular work station L Shape of size 600mm D x 750mm H (Table top) and overall height 1500mm along with writing board and pinup board as required on ground. Work station is made of prelam particle board of min 25mm thick with PVC lipping. Frame height 1500mm & thickness is min 70mm. Electric panel (cable raceway) is provided below the table top with cut out the as per required (switch plates not provided) all as shown on drawings and specified.
Work Bench of size 600 mm width x 750mm depth with 25mm thick top of both side laminated with all necessary screw and fittings all as specified and as directed.
Supply and fix Second class hard wood work in frames/ chowkats of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length all as specified and as directed.
Providing and fixing 35 mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including ISI marked Stainless Steel butt hinges with necessary screw complete all as specified and as directed..
Supply and fixing suitable size GI box with modular plate and cover in front on surface including providing and fixing 3 pin 5/6A modular socket outlet and 5/6A modular switch, connections etc as required complete all as specified and directed
M&L for circuit wiring with 2 x 1.5 sqmm FRLSH PVC insulated multistrandard copper conductor single core cable along with 1 x 1.5 sqmm earth wire FRLSH PVC insulated multistrandard copper conducor green colour single core cable in and including suitable in surface medium class PVC conduit as required and directed by Engr-in-Charge. Note :- 2 runs of 1.5 sqmm cable, 1 run of earth wire and PVC conduit will be measured as one unit.
M&L for circuit wiring with 4 x 10 sqmm FRLSH PVC insulated multistrandard copper conductor single core cable along with 2 x 10 sqmm earth wire FRLSH PVC insulated multistrandard copper conducor green colour single core cable in and including suitable in surface medium class PVC conduit as required and directed by Engr-in-Charge. Note :- 4 runs of 10 sqmm cable, 2 runs of earth wire and PVC conduit will be measured as one unit.
M&L for circuit wiring with 2 x 10 sqmm FRLSH PVC insulated multistrandard copper conductor single core cable along with 1 x 10 sqmm earth wire FRLSH PVC insulated multistrandard copper conducor green colour single core cable in and including suitable in surface medium class PVC conduit as required and directed by Engr-in-Charge. Note :- 2 runs of 10 sqmm cable, 1 run of earth wire and PVC conduit will be measured as one unit.
M&L for circuit wiring with 2 x 2.5 sqmm FRLSH PVC insulated multistrandard copper conductor single core cable along with 1 x 2.5 sqmm earth wire FRLSH PVC insulated multistrandard copper conducor green colour single core cable in and including suitable in surface medium class PVC conduit as required and directed by Engr-in-Charge. Note :- 2 runs of 2.5 sqmm cable, 1 run of earth wire and PVC conduit will be measured as one unit.
Material and labour point wiring with 1.5 sqmm FRLSH grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following concealed type wiring and including new PVC conduit of any size, complete with all PVC conduit and accessories/ fittings, brass screws, washers etc, along with modular suitable factory made Sunken boxes concealed including all cutting/chases as applicable etc or surface type PVC boxes factory made (where concealing boxes is not possible as per site conditions) to accomodate modular plates, covers modular switches & sockets etc in walls and including PVC insulated copper earth continuity conductor 1.5 Sqmm FRLSH cable green colour connected to common earth dolly complete making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge for One light / fan / bell point controlled by one, one way switch 5/6 Amps complete all as specified and as directed.
S&F 8 way (4+24) surface/recess mounting vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required, IP 43 protection, isolated neutral bus bar, mechanical impact strength IK 09, door earthing, insulated busbar assembly including necessary dummy plate complete all as required.
S&F 6 way (4+18) surface/recess mounting horizontal type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required, IP 43 protection, isolated neutral bus bar, mechanical impact strength IK 09, door earthing, insulated busbar assembly including necessary dummy plate complete all as required.
Supply and fix MCB 4 pole 63 Amps,415 Volt,50 Hz, not less than 25 KA using copper lugs for terminations complete all as specified and directed.
Supply and fixing 5 to 32A rating , 240, 10 KA 'C' curve MCB suitable for inductive load of SP complete with connections , testing and commissioning etc all as specified and directed.
Supply and fix industrial plug & socket 5 pin, 3P+N+E 415V AC surface mounting water tight 32A, IP 67 protection complete all as specified and directed
Supply and fixing suitable size GI box with modular plate and cover in front on surface including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connections etc as required complete all as specified and directed
Supply and fix 3 pin, 5 Amps Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals including PVC block all as specified and as directed.
Supply and fix LED tube light fitting with tube rod, 18/20 Watt, 4 feet long, with high lumen output, IP 20 protection, environmental friendly, energy efficient LED, electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, with integral drivers, prewired and connecting with 3 core 1 sq mm sheathed copper flexible cable, complete all as directed by Engineer-in-charge.
Supply and fix LAN port RJ 45 Cat 6 with modular box cover plate complete all as specified and directed
Supply and laying of computer LAN category-6 multi core cable ( 4 pair unshielded twisted pair cable) with high density polyethylene insulation, paired , fire retardant as IS/IEC 11801drawn through surface / concealed non metallic rigid PVC conduit / casing capping complete all as specified and directed.
Supply and fixing of medium class PVC conduit not les than 20 mm dia, along with fixing accessories in recessed including cutting of wall and making good the in case of recessed conduit as required and complete all as directed by Engr-in-Charge (For users Lan/Telephone point, layout as provided by users).
Supply and laying 1100 V XLPE LT cable, insulated, screened, bedded galvanized steel strip armoured heavy duty with aluminum conductor, of cross sectional area 70 sq mm 3.5 core laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard /dense soil all as directed.
Returning and filling in, soils, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Material and labour for earthing Complete with GI earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI strip of size 32 x 6 mm by brazing only earth strip protected with light grade GI Pipe 40 mm dia bore from earth plate electrode including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal including excavation in strata, refiling and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including suitable RCC Pit cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge. Note :- GI strip 32 x 6 mm,GI Tubing 50 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, renforcement removal of surplus soil , site clearance etc. (ii) GI earth strip 32X6 mm , GI tubing light grade 50 mm dia upto 7.5m deemed to be included the rate quoted by the contractor.
Material and labour, Galvanized earth strip of size 32 x 6 mm earth continuity or main earthing lead fixed to Wall/ trenches /ducts / buried in ground (beyond 7.5 m) in and including 40mm Galvanized iron pipe including necessary clamps, nuts, bolts, etc., and connecting up complete all as specified and as directed.
S&F 4 way (4+12) surface/recess mounting vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required, IP 43 protection, isolated neutral bus bar, mechanical impact strength IK 09, door earthing, insulated busbar assembly including necessary dummy plate complete all as required.
Supply, testing , commissioning of MCCB, FP 200 Amps 25KA breaking capacity 415 Volts, 50 HZ with thermomagnetic release and terminal spreaders in existing panel board with ISI marked incl drilling holes, making connections complete all as specified and directed by deptt.
Supply, testing , commissioning of MCCB, TPN pole 100 Amps 10KA, 415 Volts, 50 HZ disconnector fuse switch unit inside the existing panel board incl making connections complete all as specified and directed by deptt.
Supply, testing , commissioning of MCCB, TPN pole 63 Amps 10KA, 415 Volts, 50 HZ disconnector fuse switch unit inside the existing panel board incl making connections complete all as specified and directed by deptt.
Supply, Install, Testing and Commissioning of inverter type 5 star rated adjustable type Hi wall split AC with indoor/outdoor units of capacity 2.0 TR complete with cordless remote control unit, with in built filter as per latest manufactureres year for better indoor air quality complete all as directed. Note - Copper pipings with best insulation of required sizes, drain out PVC pipe and control cable of suitable rating upto 3 metre shall be included in the quoted rate.
Supply, Install, Testing and Commissioning of voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 5 KVA
Supply and fixing wall mounted heavy duty, factory made, powder coated steel brackets for outdoor units suitable for 2.0 Ton AC out door unit complete.
Supply and fix, Copper piping with 5/8 inches and 3 /8 inches complete with insulation of thickness 10 mm.
Material and labour for core cutting in concrete walls/beams and making good disturbed surface matching with the adjacent surface complete all as directed and specified
Supply, laying and testing FRLS PVC insulated copper multi strandard conductor, multi core copper cable of size 2.5 sq mm , 4 core complete.
Supply, laying and testing drain water piping with 20 mm PVC pipe complete all as directed
Supply and fix Industrial 3 pin metal clad plug & socket with 32A SP MCB complete all as directed and specified
M&L for circuit wiring with 2 x 6 sqmm FRLSH PVC insulated multistrandard copper conductor single core cable along with 1 x 6 sqmm earth wire FRLSH PVC insulated multistrandard copper conducor green colour single core cable in and including suitable in surface medium class PVC conduit as required and directed by Engr-in-Charge. Note :- 2 runs of 6 sqmm cable, 1 run of earth wire and PVC conduit will be measured as one unit.
Supply and fix concealed Double Door Vertical DB Triple pole Neutral 4 Way 415 Volt MCCB as incomer, MCCB and MCB SP as out goings as per site requirements with suitable manufacturers rated Bus Bar including necessary dummy plate complete all as required and directed by Engr-in-Charge. Note - Cutting, grooving as required and making good after works to match with the adjoining surfaces is the responsibility of the bidder, the cost inclusive in the quoted rate.
Supply and fix MCCB, 4 Pole, 100 Amps, 415 Volt, 50 Hz, not less than 25 KA using copper lugs for terminations complete all as directed by Engr-in-Charge..
Supply and fixing MCB single pole 32A, 240V, 50Hz, 10 kA, 'C' curve suitable for inductive load complete with connections, testing and commissioning etc. all as specified and directed.
ABHISHEK CONSTRUCTIONS
M/s Sri Chakrapani Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .