Loading…
Loading…
Tender ID
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹5.3 LAWARDED | AWARDED |
Tender Value
₹5.4 L
EMD Value
₹13,600
Closing Date
3 Dec 2025, 9:30 pmClosed
Public Works Department
Estimate for Electrification, Repairs and maintenance of PWD Circuit houses, PWD Division and Sub-Division office Buildings at Gadag in Gadag District FY-2025-2026 2059-80-053-4-00-200
PWD/2025-26/EL/WORK_INDENT28505
PWD/2025-26/EL/WORK_INDENT28505
Open
Electrical
Electronic Documents, First(One Cover)
PWD Division Office Gadaga
₹500
₹13,600
26 Nov 2025
26 Nov 2025
29 Nov 2025
Estimate for Electrification, Repairs and maintenance of PWD Circuit houses, PWD Division and Sub-Division office Buildings at Gadag in Gadag District FY-2025-2026 2059-80-053-4-00-200
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R41...
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C
Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.
Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operati...
Supplying and installation of insulated refrigarant copper tubing of 5/8" and 3/8" with polythen foam insulation 3 core 80 strand copper wiring between indoor and out door unit Leak testing oil and ga...
Estimate for Electrification, Repairs and maintenance of PWD Circuit houses, PWD Division and Sub-Division office Buildings at Gadag in Gadag District FY-2025-2026 SUB-2
Supplying & fixing retrofit type -PL-LED Lamp … W LED linera source with CCT 6500 degree K, CRI.70. efficacy . 80 Lumens per W, life . 25000 burning hours and Compliance to IS 10322 LEC 60598 , LM 7...
Supplying of recess mounting non intigrated type LED down light. W luminare comprising of pressure decast. extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power .COB with C...
Supplying and fixing.replacing of 6.16.32Amps electrical accessories on existing switch board.6Amps Holder
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
Wiring for lighting.power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting.power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.25mm
Supplying and drawing PVC insulated flexible copper wire of approved make.23.0.0040”
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Dong Bell
Supplying and flush mounting powder coated . galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick.Stone.C.C wall 8...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and .C. Type curve, indicator ON.OFF, energy cross-3 with Short circuit breaking capa...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and .C. Type curve, indicator ON.OFF, energy cross-3 with Short circuit breaking capa...
Supplying of .feet -PVC Batten with integrated LED tube . with high quality diffuser with Life of 25000 burning hours & 70. lumen maintenance with CRI . 80. Power Input. 220-240V@ 50.60Hz & Power fact...
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball be...
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12. Sweep (300 mm)
Fixing all types and all capacities of fluorescent .false ceiling . spot light . CFL . LED fittings indoor on the wall. ceiling . rafters . girders using 23.0.0076. twin twisted PVC insulated wires, r...
Fixing a ceiling . Wall mounting fan of all capacities and all types to the existing .S. hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary l...
Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with...
Supplying PVC.GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF ...
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13.8130-1984 and virgi...
Supply and fixing of condensing coil for Split Air Conditioners.2 Ton capacity
Supplying and fixing capacitor.s (of approved make) for window .split air conditioners. 25 to 45mfd running capacitor.
Supplying and fixing capacitor.s (of approved make) for window .split air conditioners.80 to 200mfd starting capacitor.
Supplying & fixing relay for over load protection for window and split air conditioners.
Supplying and fixing the fan motor for blowers and condenser of 1.5 HP, single shaft.double shaft suitable for split . window air conditioners.
Supplying & filling refrigerant (F-22.F.12) for air conditioning equipment.s. Which includes the labour & Nitrogen gas for pressure and leak testing.
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyc...
Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV.SV.MH.FTL street light ...
Estimate for Electrification, Repairs and maintenance of PWD Circuit houses, PWD Division and Sub-Division office Buildings at Gadag in Gadag District FY-2025-2026 Generator maintenance
Supplying and filling of Radiator Water coolant soulation for D.G.Set (A.Q.R)
Supplying and Petroeum Jelly (A.Q.R)
Supplying & 15W/40W Multi-grade Engine lubricating oil (A.Q.R)
supplying & Supply of bearing grease (A.Q.R)
Supplying cotton waste (A.Q.R) (A.Q.R)
Charges for serivicing of Diesel Engine for replacement of following items such as old oil form crank case, cleaning of crank case, cleaning of fuel tank and line, cleaning and eingine, chaning of tub...
Charges for Servicing and lubrication of Altermator of 25 to 62.5 KVA D.G.Set (A.Q.R)
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .