GE AF ADM AREA
GE AF ADM AREA GWALIOR-474020
REPAIR/ MAINT OF STREET LIGHT/SECURITY LIGHT AND GARDEN LIGHTS AND CONNECTED WORKS IN OUTSIDE POCKET AREA AT AF STATION GWALIOR
2023_MES_624389_1
8363/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE AF ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF ADM AREA
₹40,000
Yes
15 Jan 2024
20 Oct 2023
25 Nov 2023
20 Oct 2023
17 Nov 2023
3 Nov 2023
Amount
Disconnecting and Taking out U/S street light fittings any type, ( LED street light, LED flood lights, HPSV and MH lights) and fixing only street light fittings/security light fittings of any type and in any position on poles/walls/ pillars etc. including cleaning the acrylic cover, connecting the fittings with electric source with using suitable PVC insulated and sheathed flexible solid 2 core 2.5 Sqmm size copper/Aluminium conductor cable with testing of fittings complete all as specified and directed by Engineer-in-Charge. Note: Old serviceable Security light fittings/Street light fittings shall be used under this item.
S&F in replacement Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 flood light luminair with high power LED as light source 100 W LED 6000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directe. Make : Bajaj cat part No BJFL 100W LED or equivalent in make given in appendix 'B' to PS.
S&F in replacement Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP65 flood light luminair with high power LED as light source 60 W LED 4000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed. Make : Bajaj cat part No BJFL 60W LED or equivalent in make given in appendix 'B' to PS..
S&F in replacement Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 Street light luminair with high power LED as light source 45 W LED 4000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed. Make : Bajaj cat part No BRLEP 45W LED V2 or equivalent in make given in appendix 'B' to PS.
S&F in replacement Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 Street light luminair with high power LED as light source 60 W LED 6000K with1.5 sqmm 3 core copper/ aluminium conductor cable and PVC conduit pipe 15 mm bore heavy duty ISI marked duly clamped with pole at 2 places from light fitting to over head line complete all as specified and directed. Make : Bajaj cat part No BRLEP 60W LED V2 or equivalent in make given in appendix 'B' to PS.
Dimantling and taking out old U/S time switch any type and in replacement S & F in Automatic street light Switch for automatic switching OFF street light at 30 Lux level and switching ON at 10 Lux of natural light the sensor along with suitable power Contactors of rating 63 Amps 3 Phase, MCB 63 Amps-03 Nos should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and FR grade conforming to IP55. The contactors, MCBs and circuit wiring should suitable enough to take load of 25 KW equially distribution over three phase 415 Volts A/C all as specified and directed. Make:- HAVELLS Cat Part No- IHXT509120 or equivalent in make Legrand/L&T
Supply & fixing in replacement power contactors AC3, 65 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform to IEC/EN 61095 including busbar of 65 A - 4 Nos Make:-Legrand Model No-4161 69, or equivalent in make L&T/ Crompton Greave
Supply & Fixing Power Contactors AC3, 100 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform to IEC/EN 61095 including busbar of 100 A - 4 Nos Make:-Legrand Model No-4162 29, or equivalent in make L&T/ Crompton Greave all as spesified and directed.
Supply & Fixing Power Contactors AC3, 150 Amps, 3 Pole Integrated auxiliary contacts 2 NO + 2 NC Screw terminals Conform to IEC/EN 61095 including busbar of 150 A - 4 Nos Make:-Legrand Model No-4162 69, or equivalent in L&T /Crompton Greave
Dismantling and taking out old unserviceable existing U/S Changeover switch any type, supply and fixing on load four pole 160 Amp 415 Volt 50 HZ changeover with advance neutral, open execution conforming to IS 13947 (part-3); IEC:60947-3 Make :- Havells Ref No-IHCNFO0160 or equivalent in make given in appendix 'B' to PS.
Dismantling and taking out old unserviceable existing U/S Changeover switch any type and supply and fixing on load four Pole 250 Amp 415 Volt 50 HZ changeover with advanceneutral, open execution conforming to IS 13947 (part-3); IEC:60947-3 Make :- Havells Ref No-IHCNFO0250 or or equivalent in make given in appendix 'B' to PS.
Supply & fixing in repair Isolator TPN, 63 Amps having current rating 10 KA complete all as specified and directed.
Dismantling and taking out old unserviceable existing MCCB and Supply , fixing & connecting MCCB 100 Amps , 4 pole, 415 volt AC supply, having breaking capacity 16 KA and with adjustable load setting Complete all as specified and directed.
M&L for surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil.
Trimming/cutting of all trees branches and cleaning of buses upto 3.0 mtr distance both side from nearest conductor/ Earth Wire at LT overhead line including cleaning of site and depositing of material upto 250 mtr distance at site all as specified and directed by Engineer - in - Charge.
Supply and Fixing LED lamp 5 watt. Make:- Havells Cat Part No LED ADORE 5 W B22 CDL 3 STAR LAMP/ Crompton/ Bajaj.
Supply and Fixing LED lamp 9 watt. Make:- Havells Cat Part No LED ADORE 9 W B22 CDL 3 STAR LAMP/ Crompton/ Bajaj.
Supply and Fixing LED lamp 15 watt. Make:- Havells Cat Part No LED ADORE 15 W B22 CDL 3 STAR LAMP/ Crompton/ Bajaj
Supply and Fixing lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings.
Supply, fixing, connecting & testing in repair sheet metal enclosures double pole, 2 way DBs for using MCBs/ MCB isolators without bus bar all as specified & directed by Engineer - in- charge.
S&F MCB single pole & Neutral 63 Amps, 10 KA, 240 Volts, C curve complete all as specified.
S&F MCB single pole 6 to 32 Amps, 10 KA, 240 Volts, C curve complete all as specified.
Labour only for checking the serviceability of different spares/ components/ parts of High mast light fittings (LED fittings etc, any wattage/ capacity) of any description and in any position, replacement of un-serviceable/ damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning glass cover connecting to electric supply and its testing on installation etc complete all as specified and directed by Engineer-in-Charge.
Labour only for checking the serviceability of different spares/ components/ parts of security/ light fittings (LED, HPSV, HPMV, Metal Halide fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installation etc complete all as specified and directed by Engineer-in-Charge.
NOTES FOR BOQ’ ITEM NO 1.00 & 2.00:- (i) Fixing charges for Spare Parts of the new & old replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and cost of new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools,Vehicles etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, wire, gaskets and other minor items excluding the required spare parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable/ defective parts in order to maintain the fitting in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A' item No 25.00 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed. (vi) The accredit rep of Contractor shall daily report to JE E/M and receive the complaints and job card of U/S street lights on each working day and details his electirician for repair/rectification and make the street lights in serciceable condition.
(vii) If his rep fails to report concerned JE, a panelty @ Rs. 500/- per day shall be recovered. The US/defective each street lights shall be got repaired and make functional within two days from the issue of job card failing to which Rs. 50/- per light per day shall be recovered from the contractor as penalty. (viii) All security equipments will be provided by the contractor to the workers with out no extra cost. In case of any accident contractor will be responsible to give necessary medical aids and also compensation to the worker under compensation act 1923.
Supply only the following parts for HPSV/MH fittings:-
(a) Ballast (choke) for HPSV fittings of 70 Watts SON/MH open construction heavy duty Copper wound. Havells Cat part no -LHBW07170036 or equivalent in Crompton Greaves/ Bajaj.
(b) -ditto- as above but of 150 Watts Havells Cat part no -LHBW20115036 or equivalent in Crompton Greaves/ Bajaj.
(c) -ditto- as above but of 250 Watts Havells Cat part no -LHGMCJENEAC1250 or equivalent in Crompton Greaves/Bajaj.
(d) -ditto- as above but of 400 Watts Havells Cat part no -LHGMCKENEBE1400 or equivalent in Crompton Greaves/Bajaj.
(e) HPSV Lamp 70 watt, single ended tubular clear lamp (SON-T) Make:- Havells Cat Part No-LHSS16107099 or equivalent in Crompton Greaves/Bajaj.
(f) -ditto- as above but of 150 Watts Havells Cat part no -LHSS16015099 or equivalent in Crompton Greaves/ Bajaj.
(g) -ditto- as above but of 250 Watts Havells Cat part no -LHSS16025099 or equivalent in Crompton Greaves/ Bajaj.
(h) -ditto- as above but of 400 Watts Havells Cat part no -LHSS16040099 or equivalent in Crompton Greaves/ Bajaj.
(j) Ignitor for AC 230 volts for HPSV 70 to 400 watt lamp fittings. Make :- Havells Cat Part No LHGEAJENNNA1999 or equivalent in Crompton Greaves/ Philips.
Supply only the following parts for LED fittings:-
(a) Driver for street light 45 Watts Make- Wipro Cat Part No-LG53-018-002-780 or equivalent models in Crompton Greaves/Bajaj.
(b) Driver for street light 60 Watts Make-Wipro Cat Part No-LG53-028-002-1540 or equivalent models in Crompton Greaves/ Bajaj.
(c) Driver for street light 90 Watts Make-Wipro Cat Part No-LG56-036-002-1540 or equivalent models in Crompton Greaves /Philips.
(d) Driver for flood light 100 Watts Make-Wipro Cat Part No-LG76-100-050-1860 or equivalent models in Crompton Greaves /Bajaj.
(e) Driver for flood light 120 Watts Make-Wipro Cat Part No-LG76-120-050-2190 or equivalent models in Crompton Greaves /Bajaj.
Supplying & fixing in replacement new PVC insulated, served with inner sheathed pvc tape weatherproof stranded Alumunium conductor cable twin core 2.5 Sqmm size for connecting from Over head conductor to street light fittings with connector etc complete all as specified and directed by Engineer-in-Charge.
- ditto- but of size 10 Sqmm twin core.
- ditto- but of size 6 Sqmm twin core.
Disconnecting and taking out existing MS/PVC/Fibre boxes of any type and in any position on poles or fixed in the plinth and supplying and fixing in position new PVC (synthetic) boxes of size 280mm X 170mm X 115mm depth, made out with synthetic The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of ‘C’ series, 5/6 Amps and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. Note :- The contractors quoted rates for the above items are deemed to include for fixing the synthetic box in position with suitable MS clamps and/or necessary PCC as per site requirement.
Disconnecting, taking out removing and stacking servicealbe XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any type laid in trenches/ducts/ floors/ fixed to walls/poles etc complete all as specified and directed by the Engineer-in-charge for the following sizes :-
(a) LT aluminium conductor cable of size 10 sqmm to 35 Sqmm 2/3½ core.
(b) LT aluminium conductor cable of size 50 to 70 Sqmm 3½ core.
Supply, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade, laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes.
(a) LT aluminium conductor cable of size 16 Sqmm 2 core
(b) LT aluminium conductor cable of size 10 Sqmm 2 core
Laying, jointing testing serviceable XLPE/PVC insulated, armoured, heavy duty, aluminum conductor cable, 1100 volts grade, of any type obtained from BOQ item No 23.00 in trenches/ducts/ floors/ fixed to walls/poles etc complete all as specified and directed by the Engineer-in-charge for the following sizes :-
(a) LT aluminium conductor cable of size 10 sqmm to 35 Sqmm 2/3½ core.
(b) LT aluminium conductor cable of size 50 to 70 Sqmm 3½ core.
Disconnecting & taking out old U/S joints and supply, fixing, jointing and testing straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed by the Engineer-in-Charge. (MAKE : M.SEAL/YAMUNA DENSON/3M/RAYCHEM)
(a) 10 Sqmm to 16 Sqmm any core.
(b) 25 Sqmm to 70 Sqmm 3½ core.
Disconnecting existing LT over heated or burnt cable terminal Joints at existing panel/ board/feeder pillar box /overhead lines etc., cutting out over heated / burnt / unserviceable end portion of cable, stretching/ opening cable to suitable required length from available rings etc and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc complete all as specified and directed by the Engineer-in-charge for the following sizes:-
(a) LT aluminium conductor cable of size 10 to 25 Sqmm of any core
(b) LT aluminium conductor cable of size 35 to 70 Sqmm of any core
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M & L for dry and clean fine sand for cable cushioning to under ground cable for protection of pipe, complete all as specified.
M&L bricks for cover underground cable with one layer of bricks using sub class 'B' bricks (Old size) laid flat across the cable complete all as specified.
Laying only old retrieved serviceable bricks for cable protection with axis of the bricks perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.
Dismantling and taking out old us GI pipe bracket and Supplying, laying & jointing GI tubing bracket 40 mm bore, light grade as in sleeving etc for bracket 1.2 M length and as per site requirment as specified and directed by Engineer-in-Charge.
Dismantling & taking out old existing unserviceable steel & iron items from poles and supply & fixing new steel & iron cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any size and in any position to LT over head line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.
Replacement of U/S garden light and Supplying, fixing, connecting and testing the outdoor and garden lights pressure die cast powder coated housing with PC diffuser, efficient high output LED with IP 65 protection all as specified & directed by Engineer-in-Charge. Make : Havells cat part No CONEBL8WLED830PSYMTOPCM or equivalent models in Crompton Greaves /Bajaj.
Supplying & fixing in replacement, connecting and testing the Decorative gate light made up of high grade unbreakable polycarbonate material suitable for upto 20 W LED bulb including LED bulbs, Mounting Pole Dia - 60 mm (max) OD, Dimension: Width: 189 mm & Height: 216 mm IP 65 all as specified & directed by Engineer-in-Charge. Make :-Havells Cat Part No LHFOGAE1T11F015 or equivalent in make given in appendix 'B' to PS
Dismantling and taking out the old burnt out ACSR conductor including removing binding wire from insulators/jumpers and keeping a side for further disposal in accordance of direction of Engr-in-Charge.
Supply and fix LT OH lines on existing poles with ACSR conductors of size 3 of 6/1 x 3.00 mm (Ferret),1 of 6/1 x 2.59 mm (Weasel) complete all as specified and directed.
M/s Yashika Enterprises
Om Electricals
M/S KAPIL CONSTRUCTION CO
m/s varsha traders
M/s YOGESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .