| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.7 L+₹1.7 L (3.55%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹51.0 L+₹3.1 L (6.37%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
15 Dec 2021, 6:00 pmClosed
Maj Deepak Kumar
Garrison Engineer
PROVN OF CERTAIN LBW, SPECIAL REPAIR, REVENUE AND MINOR WORKS AT MIL STN BEAS AND JANDIALA GURU UNDER GE KAPURTHALA
2021_MES_489697_1
GE KPT-40/2020-21
Open Tender
Civil Works
Item Rate
270 days
Kapurthala
As per tender documents
8 documents required · 8 mandatory
₹500
Kapurthala
₹96,000
Yes
19 May 2022
22 Nov 2021
17 Dec 2021
22 Nov 2021
15 Dec 2021
29 Nov 2021
Amount
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-In-Charge.
Taking up or down, steel tubing 15mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 15mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Taking up or down, steel tubing 20mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Dismantling of wooden boarding, any description, fixed in any position with nails complete all as specified and directed .
Supply and fix 20mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Supply and fix fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle with wall flange with aerator, screwed down, screwed for iron pipe or for brass ferrule and fixed of 15mm bore complete all as specified and as directed.
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with hot bitumastic filing in proportion of bitumen and sand 1:2, including necessary form work complete all as specified and directed by Engineer-In-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles, complete all as specified and directed by Engineer-In-Charge.
M&L for brick work with sub class old size 'B' bricks, straight or curved on plan, exceeding 6m mean radius, built in cement mortar 1:6, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 5mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4, complete all as specified and directed by Engineer-In-Charge.
M&L for 10mm thick rendering in cement mortar 1:3 on ceiling surfaces, finished surface even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces and distempering walls with two coats of distemper oil emulsion, white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces and distempering ceiling with two coats of distemper oil emulsion, white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed by Engineer-in-charge.
Dismantling of AC sheets roof covering, complete all as specified and directed by Engineer-In-Charge.
M & L for RCC nominal mix, 1:2:4, Type B-1 (using 20 mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified & directed.
Material and labour for pre-cast cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) as in cover slab for manhole and similar articles with plain faces and set in cement mortar (1:6) including necessary form work complete all as specified and directed. (NOTE: Reinforcement shall be measured and paid separately.)
M&Lfor cement concrete ( 1:3:6 type C2) bed to drain pipes of 450mm bore dia including packing under and completely surrounding pipes with concrete after they are laid and tested all as specified and directed.
S&F PVC(SWR) bends 110mm dia any radius. complete all as specified and as directed by Engineer-in-Charge.
Dismantling wall and celling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and directed by Engineer-In-Charge.
M&L for ceiling framework with and including 9mm thick gypsum based ceiling tiles with wheather resistance face on back side and vinyl finish on the front fixed in 24mm GI armstrong frame work of grid 600x600 mm size, the members of snap grid frame work of GI/Steel section of 24mm wide with T-flanges, channels etc of white colour having rotary stiching on all members, i.e main runner, 1200x600mm cross tee galvanised with minimum thickness of 120 gms per/sqm passed through 500 hrs test and hanging the same with existing roof members such as rafters, pulins or other wooden members particularly provided for hanging pupose using 8mm dia mild steel bar of required length fixed with nut bolt of 50mm long and 10mm dia of neck with washer flat iron 50x6mm thick clamps etc to wooden members, complete all as specified and directed by Engineer-In-Charge.
Dismantling taking down framed trusses of span not exceeding 10m, and re-fixing the same after replacing the rusted parts if any. Note : Cost of rusted parts is deemed to be included in quoted rates by contractor, complete all as specified and directed by Engineer-In-Charge.
Dismantling mild steel work of any description, complete all as specified and directed by Engineer-In-Charge.
S&F rolled mild steel Fe 410-W (Gde-E-250) quality-A in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated), complete all as specified and directed by Engineer-In-Charge.
Supply & Fixing mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-240. Complete all as specified and directed by Engineer-In-Charge.
Supply & Fixing for rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment conforming to Fe:410-W(Gde-E-250 ) quality-A complete all as specified and directed. Note : Plate is to be fixed to watch tower upto 12mtr height.
M&L for welding not exceeding 2.5 cm in length to the metal not exceeding 6mm thick, complete all as specified and directed by Engineer-In-Charge.
S&F mild steel screw bolts (machine made) with hexagonal or Square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exc 5cm but n.exc 10cm long, dia of shank 5 to 10mm complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium anodised barrel tower bolt of extruded section 200mm long, complete all as specified and directed by Engineer-In-Charge.
Supply & Fixing Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed by Engineer-In-Charge.
Supply and fixing 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane, complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer. Complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint. Complete all as specified and directed by Engineer-In-Charge. (Note :- The height of watch tower upto 12 mtr).
S&F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor, complete all as specified and directed by Engineer-In-Charge.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. Complete all as specified and directed by Engineer-in-Charge.
-Ditto- all as per item No 38 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders. Complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete Type B-1, 1:2:4 (using 20mm graded stone aggregates) as in drain bottom benching, parapets walls, copings, cills, steps etc including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M&L for M.S. curtain rod of 25mm dia, powder coated having wall thickness 1mm, with aluminium powder coated brackets fixed to wall with screws, gutties @ 1500mm C/C (approx) and curtain rings (Minimum 5 Nos rings per running mtr of curtain rod) including taking out the existing old pelmet box along with old curtain rods and removing, complete all as specified and directed by Engineer-in-Charge.
S&F magnetic type ball & catch fixed with screws to door frame complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation & getting out, complete all as specified and directed by Engineer-in-Charge.
Surface dressing not exceeding 15cm deep and getting out in soft/loose soil. Complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm for soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point. Complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete 100mm diameter pipes laid on 150mm thick moorum/sand/crushed stone bed with excavation in trenches up to depth 1.65m in any type of soil, including construction of manholes of standard size made of brick masonry in CM 1:4 & plastered with 15mm thick in CM 1:4, RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional.
M&L for construction Soakage wells including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including chamber and screen chamber made of brick masonary in CM 1:6, RCC cover slab in M-25/SFRC cover with reinforcement with 10mm dia TMT bars, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8m diaX3.0m effective depth complete all as specified and directed by Engr-in-Charge. (TD Drg shall be provided by Engr-in-Charge at site.)
M&L for machine pressed precast concrete interlocking paver block, 80mm thick, any shape and size, confirming to IS-15658-2006, M-35 Grade, with grey cement and no pigment complete all as specified and directed. Make:Supertile.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-30 grade with grey cement and pigment complete all as specified and directed by Engineer - in - Charge.
M&L for Cement concrete type C-2, 1:3:6 (40mm stone Graded agg) as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-In-Charge.
M&L for sand filling under floor or in foundation including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick cement concrete 1:4:8 type B–2 using 40mm graded stone aggregates as in flooring finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge .
M&L for 100 mm thick cement concrete 1:2:4 type B–1 using 20mm graded stone aggregates as in flooring/hard standing finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge .
Extra for forming fair finished drain or channel inner girth 30cms in cement concrete, using extra cement including forms, moulds mi- tred/ stpped ends etc complete all as specified and directed.
Extra for forming fair finished drain or channel inner girth 47cms in cement concrete, using extra cement including forms, moulds mi- tred/ stpped ends etc complete all as specified and directed.
M&L for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) in foundations, filling, mass concrete etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for design mix M-25 concrete (using 20mm graded stone aggregate), as in Foundations, including rafts, footings, foundation beams; plinth beams; base for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for Design mix M-25 concrete (using 20mm graded stone aggregate), as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge.
M&L for Design mix M-25 concrete (using 20mm graded stone aggregate), as in roof beams, cantilevers, bressummers, lintels upto and over 1.5 m clear span complete all as specified and directed by Engineer-in-Charge.
M&L for RCC design mix M-25 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-Charge.
M&L for RCC design mix M-25 (using 20mm graded crushed stone aggregate) as in suspended chajjas and the like, complete all as specified and as directed by Engineer-in-Charge.
Use and waste formwork to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and as directed by Engineer-in-Charge.
Use and waste formwork to square/reactangular sides of pillars, posts, struts, piers, columns, and stanchions fair and finished surface, complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed by Engineer-in-Charge.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed by Engineer-in-Charge.
Use and waste formwork to sides and soffits of floor or roof beams, beam, RCC coping fair and finished surface, complete all as specified and directed by Engineer-in-Charge.
M&L for fly ash brick work Old size bricks in cement mortar , straight or curved on plan, exc 6m mean radius, built in cement mortar 1:6,complete all as specified and directed by Engineer-in-Charge.
M&L HD Digital Glossy finish wall tiles coloured of size 300x600x10mm thick , jointing in neat cement slurry and pointing in colour cement to match including 10mm thick plaster in cm 1:4 complete all as spd and directed.MAKE: Kajaria(Cristina Bianca), Nitco(Giza Beige Lt G*), H&R Johnson(Tribeca white)
S&F Stainless Steel water curtain of size 9.00x5.0 feet (each), 220V/380V for indoor room, developed using advanced methodologies, Equiped with multitude of water curtain nozzles & corresponding number of finely integrated with immersible Pump, overflow drain & freshwater refill facility, water curtain conduction plate and 03 Nos, 6 watts in the nozzle underwater lights with all connected fittings & fixtures with consultancy complete all as specified and directed by Engineer-in-Charge.
M&L for pre-construction antitermite treatment by treating the bottom and sides of excavation at the rate of 5 litres of ATT emulsion per Sqm of surface area, complete all as specified and as directed by Engineer-in-Charge.
M&L for pre-construction antitermite treatment by treating the back fill in contact with foundation at the rate of 7.5 litres of ATT emulsion per Sqm of vertical surface area in contact, complete all as specified and as directed by Engineer-in-Charge.
M&L for pre-construction antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of ATT emulsion per Sqm of surface area, complete all as specified and as directed by Engineer-in-Charge.
M&L for pre-construction antitermite treatment by treating the soil under plinth ptotection at the rate of 5 litres of ATT emulsion per Sqm of surface area, complete all as specified and as directed by Engineer-in-Charge.
M&L for pre-construction antitermite treatment by treating the soil alongwith external perimeter of bldg at the rate of 2.25 litres of emulsion per metre of the wall, complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new concrete surface and apply water proofing treatment to roof with APP (Atactic poly propylene) modified prefabricated five layer 3mm thick water proofing membrance super therolay of STP limited wth non-woven polyster male reinforcement of 160gm, weight of membrane @3.6kg/sqm over a solvent based bitumen primer, shalitex primer @ 0.3 lt/sqm by the same manufacturer conforming to IS-3384-1986.Apply two coat of alumnium paint on top of membrane surface after laying the membrane incl all cleaning Note : The membrane shall be laid using butane torch. The end lap should be 100 mm and the side lap must be minimum 75 mm. The membrane shall be first laid upto the parapet wall junction and then shall be overlapped with naother membrane (flashing) with and overlap covering upto a distance of 300mm. In case of parapet height is less than/ upto 500 mm membrane shall be terminated at the top of parapet. (Water ponding test should be carried out for 72 hrs of water proofing treatment).
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified.
M & L for RCC NP2 pipe 450mm dia bore and jointed complete with collars in cement joint as in culvert complete all as specified and directed.
M & L for RCC NP2 pipe 100mm dia bore and jointed complete with collars in cement joint as in culvert complete all as specified and directed.
M&Lfor cement concrete ( 1:3:6 type C2) bed to drain pipes of 100mm bore dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and directed.
M&Lfor cement concrete ( 1:3:6 type C2) bed to drain pipes of 450mm bore dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and directed.
S&F powder coated Anodised aluminium frame (Thickness of powder coating not less than 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. Complete all as specified and directed by Engineer-in-Charge.
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified.
S&F 5.50mm thick sheet glass, ordinary quality and glazing with beads fixed with metal panel pins with solar control film 25micron reflective type sicked to glass panes as per instruction of manufacturers, complete all as specified and directed by Engineer-in-Charge.
Supply and fix transparent 12mm thick Toughened glass, ordinary quality and glazing with beads fixed with metal panel pins with solar control 25micron reflective type film sicked to glass panes as per instruction of manufacturers complete all as specified and directed by Engineer - in – Charge.
S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos) suitable handle (1 No.), complete all as specified and directed by Engineer-in-Charge.
S&F stop valves, cast copper alloy, bore dia of pipe in 15mm, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed but fancy type, Chromium Plated with long shank and cup (concealed type) etc. Complete all as specified and as directed by Engineer-in-Charge.
Supply, hoisting and fixing in position Rotational moulded Polyethylene water storage tank, 500 litres capacity conforming to IS-12701 (1989) cylindrical vertical type two-layered wall construction with closed top including inlet, outlet and wash out holes of approved make including taking down the old unserviceable water storage tank complete all as specified and directed.
Supply & Fixing 20mm dia Ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210gms) complete all as specified and directed.
Supply and fix in repair, 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by the Engineer-in-Charge.
Supply and fix 6mm thick PVC hollow wall paneling plain/coloured/printed fixed with screws to wall and corner, edges of panels be sealed with approrite arrangement, colour and pattern as approved by Engineer-in-Charge. Complete all as specified and as directed by Engineer-in-Charge.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roof, walls etc Fixed with L-type or J-type or cranked hook bolts etc complete all as specified and directed.
M&L for asbestos cement, two piece adjustable plain wing ridge 6mm thick sheets fixed with L-type or J-type or cranked hook bolts etc complete all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by engr-in-charge. (Note:- The height of Watch tower upto 12 mtr).
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by engr-in-charge. (Note:- The height of Watch tower upto 12 mtr).
M & L for point wiring for one light or one fan point controlled by one switch or with one switch and regulator with PVC unsheathed single core multistranded copper conductor (FRLS) cable of size 1.5 Sqmm (nominal area) in and including PVC conduit 20 mm bore by cutting chases in wall by cutter and making good the surface in cm 1:3 and to the original specification and cast iron /pressed steel concealed terminal boxes including providing 3mm thick plastic laminated sheet cover (Hylem) including one run of PVC insulated copper conductor (FRLS) cable of size 1.5 sqmm with green insulation as earth wire and connected to earth dolly complete all as specified. (Switch/Socket outlet to be measured & paid for separately). Make of cable: Finolex/Anchor/Havell’s
-Ditto- all as per Srl item No 97 here in before but for 3 pin socket outlet 5 Amps on same board .
-Ditto- all as per ser item 97 above but for 3 pin socket out let 5 Amps on independent board
-Ditto- all as per srl item No 97 here in before but for 3 pin socket outlet 15 Amps on independent board with PVC unsheathed copper conductor cable of size 2.50 Sqmm including copper earth wire of size 2.50 Sqmm and connected to common earth dolly complete all as specified. (Switch/socket to be measured & paid for separately)
Supply & fixing switch piano flush type 5 Amp single pole one way.
Supply & fixing switch piano flush type 15 Amp single pole one way.
Supply & fixing socket outlet 5 pin 5 Amps flush type multipurpose.
Supply & fixing socket outlet multipurpose 2 in one, 3 pin 5/15Amps flush type.
S & F surface mounting energy saving LED tube light fitting/ Batten with LED T8 Tubelight with PC body, 1x20W, 230V , Cat Part No of Batten DMLN1LT8-16 & Cat Part No LT8-20-865-2 for LED T8 Tube light Make- Crompton or equivalent complete with all accessories.
Supply and fixing MCB single pole 6 to 32 Amps 240 Volts, B Series Product Code CSMBS1B6 to CSMBS1B32 Make- C&S or equivalent in Havells/GE/ L &T/Legrand
Supply and fixing MCB single pole 32 Amps 240 Volts SPN , B Series Product Code CSMBS1B6N to CSMBS1B32N Make- C&S or equivalent in Havells/GE/L&T/Legrand)
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with bus bar, earth wire and neutral link, 8 ways, 240 volts. ( Make- Havells/Legrand)
Supply & fixing ceiling rose surface bakelite 65 x 50mm three terminal complete all as specified and as directed by Engineer-in-Charge. Make – Anchor/Leader/Bajaj
Supply & fixing Angular lamp holder insulated body with back plate suitable for batten fittings including 1 x 9 W LED Lamp Make- Havells LED ADORE 9 W B22 WW 3 STAR LAMP Cat No LHLDEUEEMC8R009 or equivalent all as specified and directed by Engr in Charge.
Supply & fixing fan regulator electronic step type and making connections. (Make : Anchor/Leader/Bajaj).
Supply & fix ceiling fan complete with electronic type regulator of 230 V,1200 mm sweep with all accessories complete all as specified and diretced by Engr in ChargeMake- Bajaj/Crompton/ Orient/Polar or equivalent
M&L for earthing complete with galvanized steel earth plate trode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected to GI earth wire 4mm dia by means of bolts, nuts and washers (earth plate covered with charcoal dust and common salt in alternate layers) GI earth wire protected by galvanized steel pipe light grade of 15 mm dia upto switch board and connected to main switch board, including provision of 20mm dia GI tubing light grade watering pipe with funnel and wire mesh PCC earth pit (1:3:6) type C-1 covered with CI cover hinged with frame including excavation and earth work complete all as specified and shown in electrical plate No 5 of SSR Part I including testing on completion.
Supply and fixing in replacement sub main wiring with two single core FRLS insulated cable with copper conductor stranded and sheathed of size 6 Sq mm in and including PVC conduit including 1 x 6 Sq mm FRLS copper earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Havells/Plaza/Indo Asian
Supplying and laying bricks as protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed.
Supplying and laying in trenches sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified & directed. (Note : Depth of thickness of sand 18cm after punning down shall be increased, recorded & paid)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED bldg security light fitting 15 watt Powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washers all as specified and directed by Engineer-in-Charge.Make- Crompton Cat Part No LSTS-15-CDL or equivalent in Bajaj/Philips/C&S/Havells : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
M&L for GI Pipe 'light grade' galvanized of bore size 40mm with all fitting laid in trenches/on pole/road crossing of size 40mm
Supply and fixing LED Recessed full open 2x2 Tile 36 Watt, glare free uniform illumination having white powder coated extruded aluminium body suitable for armstrong and grid ceiling Product code LCTLRN-36-FO-CDL (Polaris I) of Crompton or equivalent in Bajaj/Havells/C&S/Halonix/Polycab.
Supply and fixing PVC Ventilation Fan 150mm sweep, 240 Volts Colour -White Make-Crompton Model Mountair 6" single phase 230/240V, AC including making of hole on wall for passing out air and provision of flexible three core copper conductor cable of 23/0.0076 up from ceiling rose to fan and grouting 04 Nos bolts in wall.
Supply and fixing Plug and socket enclosures in sheet steel enclosures (without MCBs) Cat Part No . DSDPUSN020. Make- Standard or equivalent in Havells/L&T/Legrand.
M/S MAHAJAN CONSTRUCTION CO
ARR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .