Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LRejected-Finance | L1 | Rejected-Finance Tender was cancelled. non commencement of | |
| 2 | L2₹14.0 L+₹1.8 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Tender was cancelled. non commencement of | |
| 3 | L3₹14.3 L+₹2.2 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Tender was cancelled. non commencement of works | |
| 4 | L4₹16.0 L+₹3.8 L (31.3%)Rejected-Finance | L4 | Rejected-Finance Tender was cancelled. non commencement of | |
| 5 | L5₹17.0 L+₹4.9 L (40.1%)Rejected-Finance | L5 | Rejected-Finance Tender was cancelled. non commencement of |
Tender Value
₹16.5 L
EMD Value
₹32,960
Closing Date
8 Sept 2017, 6:00 pmClosed
AGM(E-E)-II,Madurai Airport
AGM(E-E)-II,Madurai Airport Airport
Replacement of Old Cassette/Vertical/Split ACs
2017_AAI_2446_2
AAI/MDU/E-E/MDU-150/NIT-08
Open Tender
Electrical Works
Works
90 days
Localizer NDB CCR DVOR Glidepath
Pls refer NIT
11 documents required · 11 mandatory
₹560
Yes
Airports Authority of India
₹32,960
Yes
30 Jun 2021
24 Aug 2017
14 Sept 2017
24 Aug 2017
8 Sept 2017
24 Aug 2017
24 Aug 2017 - 8 Sept 2017
Amount
SITC of 4.0 TR cassette Air conditioner (5 star rated) unit capable of catering 1000 CFM(Mini.) comprising of Rotary/scroll compressors with evaporators, fan section and condensing unit etc. suitable for operation on 415V, 50Hz, three phase supply including initial gas charging, providing MS stand/platform for outdoor units, inbuilt protection against phase failure, low/high voltage cut off etc including connections with existing copper suction & return lines complete as required.
Flushing of existing copper suction and return piping of cassette units with nitrogen gas, nitrogen pressure testing, vacuumizing, copper bracing (if required) etc complete.
Supply and fixing of following size copper refrigerant piping for interconnecting indoor unit and condensing unit / extending of existing copper piping with necessary fitting, supports, insulation with closed cell elastometric nitrile rubber insulation etc complete as required. a) 3 / 4” dia
Supply and fixing of following size copper refrigerant piping for interconnecting indoor unit and condensing unit / extending of existing copper piping with necessary fitting, supports, insulation with closed cell elastometric nitrile rubber insulation etc complete as required. a) 3 / 8” dia
SITC of 1.5 TR Air conditioner (5 star rated) consisting of non-ductable indoor unit with remote control and outdoor condensing unit comprising of sealed compressor suitable for operation on 230V, 50Hz, AC supply with copper coil with aluminum fins, copper pipings upto 5 meters, suitable size interconnecting cabling, drain piping, first charge of refrigerant, providing raised platform/MS stand for outdoor units etc complete as required.
Supply and fixing of wall mounting type automatic electronic voltage stabilizer suitable for 1.5TR Split Air conditioners having capacity 4KVA single phase, an input voltage range of 180-270V, with high/low voltage cut off, ON delay etc complete as required.
SITC of 2.0 TR Air conditioner (5 star rated) consisting of non-ductable indoor unit with remote control and outdoor condensing unit comprising of sealed compressor suitable for operation on 230V, 50Hz, AC supply with copper coil with aluminum fins, copper pipings upto 5 meters, suitable size interconnecting cabling, drain piping, first charge of refrigerant, providing raised platform/MS stand for outdoor units etc complete as required.
Supply and fixing of wall mounting type automatic electronic voltage stabilizer suitable for 2TR Split Air conditioners having capacity 5KVA single phase, an input voltage range of 180-270V with high/low voltage cut off, ON delay etc complete as required..
SITC of 3.0 TR (5 star rated) vertical split type Air conditioner consisting of floor mounted vertical indoor unit with remote control and outdoor condensing unit comprising of sealed compressor suitable for operation on 415V. 50Hz, three phase AC supply, copper piping upto 5 meters, initial charging of refrigerant, providing MS stand for outdoor units etc complete as required.
Dismantling of following capacities of ACs (both indoor and outdoor units) including stacking at stores etc complete. 1.5 Ton Split
Dismantling of following capacities of ACs (both indoor and outdoor units) including stacking at stores etc complete. 2 Ton Split
Dismantling of following capacities of ACs (both indoor and outdoor units) including stacking at stores etc complete. 3 Ton Vertical Split
Dismantling of following capacities of ACs (both indoor and outdoor units) including stacking at stores etc complete. 4 Ton cassette
TRAC FUJICO AIR SYSTEMS LLP
VELOCITY AIRCON
DEEPAKELECTRICALS
CHENNAI ENGINEERING SERVICES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .