Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAdmitted-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110063 | WEST | DELHI | 110063 | ₹8.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.9 CrAdmitted-Finance DOOR NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESHWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹8.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹10.9 CrAdmitted-Finance NOT SPECIFIED | ₹10.9 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical NOT SPECIFIED | - | - | Rejected-Technical NO remarks in WLR ADG P Chennai for the QE Dec 2025 |
| Sl No | Description | Qty | Unit | MANU CREATIONS L3 | Mahamaruti Constructions L2 | M/s R. K. Bhambri L1 |
|---|---|---|---|---|---|---|
| 1.00Schedule "A" Part – I:- Sewage Treatment Plants (This schedule is not pre-priced by MES. Contractor has to quote his own rates.) | ||||||
| 2.00Design, Supply, Installation, Testing and Commissioning of fully automatic Sewage Treatment plant(STP) of the under mentioned capacities with suitable technology as per geographic location, temperature differential and rainfall. The design of Plant can be either biological process or physical separation process with chemicals as secondary treatment process and must comply with the teritiary treated water parameter and also considering the points while designing the STP:- | ||||||
| 2.01 | 900 KLD capacity | 1 | Each Job | 3,30,00,000 ₹3.3 Cr | 2,00,00,000 ₹2 Cr | 2,66,25,000 ₹2.7 Cr |
| 2.02 | 300 KLD capacity | 1 | Each Job | 1,65,00,000 ₹1.6 Cr | 1,20,00,000 ₹1.2 Cr | 1,27,80,000 ₹1.3 Cr |
| 2.03 | 200 KLD capacity | 1 | Each Job | 1,45,00,000 ₹1.4 Cr | 1,12,00,000 ₹1.1 Cr | 1,06,50,000 ₹1.1 Cr |
| 3.00Designing, Supplying, Developing, lnstallation, Integrating and Commission STP SCADA System along with various Automation equipment for under mentioned STPs:- | ||||||
| 3.01 | 900 KLD capacity | 1 | Each Job | 7,70,000 ₹7.7 L | 20,00,000 ₹20 L | 6,75,000 ₹6.8 L |
| 3.02 | 300 KLD capacity | 1 | Each Job | 7,20,000 ₹7.2 L | 19,00,000 ₹19 L | 4,50,000 ₹4.5 L |
| 3.03 | 200 KLD capacity | 1 | Each Job | 7,10,000 ₹7.1 L | 18,00,000 ₹18 L | 4,50,000 ₹4.5 L |
| 4.00Schedule "A" Part – II to XI: NOTE: Schedule "A" Part – II to Part – XI are prepriced by MES. | ||||||
Updated dates
Tender Value
₹8.4 Cr
EMD Value
₹7.5 L
Closing Date
19 Jan 2026, 6:00 pmClosed
CWE NO 2 VISAKHAPATNAM
CWE NO 2 VISAKHAPATNAM, HQ CE N COMPLEX, RAILWAY STATION ROAD, VISAKHAPATNAM - 530004
PROVISION OF STPs AT INS CHILKA
2025_MES_739635_1
82741
Open Tender
Machineries/ Mechanical Engg Items
1680 days
GE CHILKA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER CHILKA
₹7.5 L
Yes
17 Mar 2026
13 Nov 2025
27 Jan 2026
13 Nov 2025
19 Jan 2026
2 Jan 2026
13 Nov 2025 - 2 Jan 2026
Open well submersible pump set multi stage 5 HP Single Phase 230 Volts 50 Hz head-30 mtr with all fittings and fixtures complete
Design, Supply, Installation, Testing and Commissioning of fully automatic Sewage Treatment plant(STP) of the under mentioned capacities with suitable technology as per geographic location, temperature differential and rainfall. The design of Plant can be either biological process or physical separation process with chemicals as secondary treatment process and must comply with the teritiary treated water parameter and also considering the points while designing the STP:-
900 KLD capacity
300 KLD capacity
200 KLD capacity
Designing, Supplying, Developing, lnstallation, Integrating and Commission STP SCADA System along with various Automation equipment for under mentioned STPs:-
900 KLD capacity
300 KLD capacity
200 KLD capacity
Lumpsum price worked out by the contractor for "BUILDINGS AND STRUCTURES", as listed in Schedule "A" Part – II (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "SITE CLEARANCE, AREA DEVELOPMENT AND EARTH WORK", as listed in Schedule "A" Part – III (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – IV (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V (Refer pre priced schedule attached seperately).
Schedule "A" Part – II to XI: NOTE: Schedule "A" Part – II to Part – XI are prepriced by MES.
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VII (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VIII (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "ROAD, PATH & HARD STANDING", as listed in Schedule "A" Part – VI (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – IX (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "GATE, FENCING AND COMPOUND WALL", as listed in Schedule "A" Part – XI (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - X (Refer pre priced schedule attached seperately).
Miscellaneous items for Internal Electrification :
M&L for Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 25 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and modular GI Flush Box made out of suitable size and required module frame with top cover plate, for fixing modular switches, fittings, regulators, blanking plates etc. concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one switch complete all as specified and as directed.
Schedule "A" Part - XII (Miscellaneous items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. Contractor has to quote his own rates.
All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 5/6 A modular socket point on independent board complete. Note: One circuit with maximum 04 points
All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A modular socket point on independent board complete. Note: One circuit with maximum 01 points only
All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 4.0 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 4.0 sqmm green in colour as earth lead for 20 A metal clad socket point complete. Note: One circuit with maximum 01 points only
S&F LED bulb 10 watt B-22 230 volts complete all as specified.
S&F LED emergency inverter bulb 10 watt B-22 230 volts with atleast 4 hrs backup complete all as specified.
Supply & Fixing V-TPN DB with sheet metal enclouser, 06 way IP-43 with rated 250A fully insulated copper bus bar & shrouded neutal bars, double door suitable for MCCB as incommer and MCB SP/TP as outgoing with neutralbar, earthbar and cable tiles for cable managements, incl cutting chases for DB of reqd size and making good distrubed surface area complete all as specified and as directed
S&F MCCB, 4P, 16KA, 415V, with thermal magnetic protection, 25 to 100 A, ISI Marked complete all as directed.
S&F MCCB, 4P, 25KA, 415V, with thermal magnetic protection, 160 A, ISI Marked complete all as directed.
Miscellaneous items for Internal water supply
S&F for 15mm dia Two way Bib cock, cast copper alloy with wall flange and lever handle, screwed down, screwed for pipe or for unions and fixed complete all as specified and as directed.
S&F for Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25m long flexible and ABS wall hook including making connections and fixed in position complete in all reapect as specified.
Miscellaneous items for Sewage Disposal
M&L for SRFC factory made manhole cover square/rectangular/ circlar shape for using cover to maholes complete as directed.
Miscellaneous items for External Electric supply
All as per item No 16.01 here in before but for one light point controlled by 2 way switches complete all as directed.
M & L for drop out fuse assembly mounted on insulator and steel frame horizontal/vertical type for HT 11 KV lines including connections etc complete all as specifeid & directed.
INCOMING (a) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp 01 nos(incoming) complete and all as per standard pratice -1 Job (b) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA 1 Nos (INCOMMING).
OUT GOING (a) panel mounted on load Changeover 4 Pole, 415 V 100 Amps 1Nos (b) MCCB 4 Pole, 415 V, Adjustable type,63 Amps with breaking capacity 16 KA 3 Nos (c) MCCB 4 Pole, 415 V, Adjustable type,40 Amps with breaking capacity 16 KA 3 Nos (d) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice-3 set Note :- (i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on - off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor (Incoming) and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per standard practice.
Supply and fixing in repairs energy saving LED street light fittings,100 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED 5700K connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make: Crompton LSTS -90-CDL-M ( NEXUS NEO) or equivalent in Philips/Bajaj/ Wipro
Supply and fix weather proof looping in box PVC without side dimension 160 x160x105 mm comprising of connector and MCB SP 6-32 A including mounting arrangements and lugs etc.and removing existing defective looping box and taken as credit complete all as specified and as directed. Make :Sintex/Hensel or as specified in PS
Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracket complete all as specified.
Supply and install APFC PANEL with MD-LX capacitor 50 KVAR with 6 steps ( 2+3+5+10+15+15) and MCCB as incomer
Supply and fix fire extinguisher dry chemical powder (ABC) Type , capacity 6 kg , as per IS 15683 , all as specified and as directed.
Supply and fix fire extinguisher Mechanical foam extinguisher (stored pressure type) , capacity 9 ltrs , as per IS 15683 , containing 540 ml AFFF liquid ISI marked,IS 4989 part -II and polyurethane caoted CO2 gas cartridge ISImarked 4947 complete with gun metal,union cap, nylon hose with plastic foam making branch and wall mounting bracket all as specified and as directed.
Miscellaneous items for External Electric supply
S/F double wall corrugated ,High density polyethylene pipes (HDPE) of 100 mm dia laid in trenches walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge complete.
Supply, laying ,jointing and testing 2"/63 mm bore HDPE pipe, PR-100 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed.
Supply, laying ,jointing and testing 1"/32 mm bore HDPE pipe, PR-100 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed.
Supply and connecting flat three core, PVC insulated industrial cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed.
Supply and Fix Submersible Pump DOL Starter 5/7.5 HP
DG Set
Schedule "A" Part – I:- Sewage Treatment Plants (This schedule is not pre-priced by MES. Contractor has to quote his own rates.)
Supply, Install , testing and commissioning of silent engine DG set of minimum Capacity 60 KVA, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to CPCB-IV approved norms complete with AMF panel, Relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS including PCC foundation etc. complete all as specified and as directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 2nd year after completion of defect liability period complete all as specified and directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant during 2nd year after completion of defect liability period complete all as specified and directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed.
Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed.
Schedule "A" Part - XIII (Outsourcing of Maintenance and operation) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. Contractor has to quote his own rate.
Schedule "A" Part - XIII (Comprehensive Maintenance This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. Note : Comprehensive mainteance include: (a) Repair/replacement of FAB media SBR/MBBR or any technology. (b) Repair/replacment of aur blower oil. (c) Repair/replacement of drives and other accessories of SCADA system for controlling operation of various motors. (d) Calibration of SCADA system including updation of softwares including replacement of necessary spares, checking relay contracts, replacement of relays, MCBs as per existing make and size, checking of alarm system to make it functional properly. (e) Repair/replacement of wornout/ unserviceable "V' belt for power transmission of air blowers. (f) Repair/replacement of defective MNX9 contactor AC3 rating 9 amps AC1 any rating with 1 NO + 1NC auxillary contracts. (g) Removing the old filtermedia and cleaning of internal walls of Dual media pressure filters at STP.
Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SC
ADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed.
Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_828181.xls
BOQ • 0.32 MB
TENDER.pdf
Tender Documents • 1.75 MB
PREPRICED.pdf
Additional Documents • 2.23 MB
Download all tender documents and submit your bid