Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹45,000Qualified Make: BPL
Model: OG4305 D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: OG4305 | L1 | Qualified | |
| 2 | Disqualified Make: Philips
Model: Philips Respironics and EverFlo TILAK NAGAR DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | Make: Philips
Model: Philips Respironics and EverFlo | - | Disqualified | |
| 3 | Disqualified Make: LIFE PLUS
Model: lifeplus HOUSE NO 2 347 SECTOR2 JANKIPURAM EXTENSION JANKIPURAM EXTENSION LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Make: LIFE PLUS
Model: lifeplus | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Jul 2018, 2:00 pmClosed
oxygen concentrator Average Turn Over of Last 3 Years 1000000 Lakh (s) Experience with Gov. Required 3 Year (s) Oxygen Concentrator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Type Type of Oxygen Concentrator Portable - Flow Rate Flow Rate (Minimum) at 93% + - 3% oxygen purity (Litres per minute) 5 Oxygen outlet and pressure and tank capacity Oxygen outlet(s) Single or Dual Single
Single or Dual
Others Outlet pressure (KPa) 95 - Oxygen Concentration monitor available Yes - Oxygen tank capacity (Ltrs) 5 Power Source and Battery Power Source Electrical Operated Electrical Operated
Battery Operated
Electrical cum Battery Operated Average Power Consumption (Watt) 480 - Power Efficiency (W/LPM) 53 - 1/5 Battery duration in hours (If Battery operated or Electrical cum Battery operated) 9 3
6
9
12 Battery Charging (If Battery operated or Electrical cum Battery operated) (Hrs) 1 - operating temperature humidity and altitude Operating temperature Range (from 12 degree C to 32 degree C or better for portable type - Operating humidity up to 95% Yes - Operating altitude Range up to (in meters) above sea level 1000 Type of Operation Type of operation Continuous Flow Type Pulse Dose Type
Continuous Flow Type
Pulse Dose Cum Continuous Flow Type Air Delivery Adjustable Air Delivery mechanism true - Continuous flow rate (Litre per Minute) up to 5 - Noise Level Noise Level (dB) Less than 40 db less than 10 dB silent type
Less than 40 db
Less than 60 db Alarms and Alerts Digital Display LCD - Audio Alarm YES - Visual Alarm YES - Alert of technical fault YES - Alert of wrong Battery YES - Alert of Depleted Battery YES - Alert of high Breath rate YES - Alert of low oxygen purity YES - Alert of No Breath YES - Alert for No flow YES - Alert for Low flow YES - Alert for High flow YES - Alert of Low Pressure YES - 2/5 Alert of High Pressure YES - Alert of High temperature YES - Alert for Power failure YES - Alert for service requirement YES - Weight and Dimensions Weight (Kg) 25 Dimension (height) (mm) 365 - Dimensions (Length) (mm) 375 - Dimensions (Width) (mm) 600 - Flame Retardancy Flame Retardant true Warranty Manufacturer warranty Period (Years) 1 1
2
3 Spare part availability YES - standards and certifications Comply with International Standards true Name of International standards USFDA - FDA approved true - Conformity to ISO 80601-2-69:2014 of the Medical Electrical Equipment – Part 2-69: Particular requirements for basic safety and essential performance of oxygen concentrator equipment Yes - Availability of test report CE or EC certification (to be furnished by Seller to Buyer on demand) in accordance with Appendix II(excluding section 4) of medical device directive 93/42/EC & its amendment or equivalent true - Availability of Test Report(To be furnished by Seller to Buyer on true - 3/5 demand) from Central Govt/NABL/ILAC accredited lab to prove conformity to specification Test report number and date - - Name and address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dontamsetty Chandrasekhar N 500052
Shivarampally
Rajendra nagar
Hyderabad 1 20
313142
GEM/2018/B/44422
oxygen concentrator
20 days
Telangana; Ranga Reddy
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| oxygen concentrator Average Turn Over of Last 3 Years 1000000 Lakh (s) Experience with Gov. Required 3 Year (s) Oxygen Concentrator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Type Type of Oxygen Concentrator Portable - Flow Rate Flow Rate (Minimum) at 93% + - 3% oxygen purity (Litres per minute) 5 Oxygen outlet and pressure and tank capacity Oxygen outlet(s) Single or Dual Single | - | - | - |
| Single or Dual | - | - | - |
| Others Outlet pressure (KPa) 95 - Oxygen Concentration monitor available Yes - Oxygen tank capacity (Ltrs) 5 Power Source and Battery Power Source Electrical Operated Electrical Operated | - | - | - |
| Battery Operated | - | - | - |
| Electrical cum Battery Operated Average Power Consumption (Watt) 480 - Power Efficiency (W/LPM) 53 - 1/5 Battery duration in hours (If Battery operated or Electrical cum Battery operated) 9 3 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| 12 Battery Charging (If Battery operated or Electrical cum Battery operated) (Hrs) 1 - operating temperature humidity and altitude Operating temperature Range (from 12 degree C to 32 degree C or better for portable type - Operating humidity up to 95% Yes - Operating altitude Range up to (in meters) above sea level 1000 Type of Operation Type of operation Continuous Flow Type Pulse Dose Type | - | - | - |
| Continuous Flow Type | - | - | - |
| Pulse Dose Cum Continuous Flow Type Air Delivery Adjustable Air Delivery mechanism true - Continuous flow rate (Litre per Minute) up to 5 - Noise Level Noise Level (dB) Less than 40 db less than 10 dB silent type | - | - | - |
| Less than 40 db | - | - | - |
| Less than 60 db Alarms and Alerts Digital Display LCD - Audio Alarm YES - Visual Alarm YES - Alert of technical fault YES - Alert of wrong Battery YES - Alert of Depleted Battery YES - Alert of high Breath rate YES - Alert of low oxygen purity YES - Alert of No Breath YES - Alert for No flow YES - Alert for Low flow YES - Alert for High flow YES - Alert of Low Pressure YES - 2/5 Alert of High Pressure YES - Alert of High temperature YES - Alert for Power failure YES - Alert for service requirement YES - Weight and Dimensions Weight (Kg) 25 Dimension (height) (mm) 365 - Dimensions (Length) (mm) 375 - Dimensions (Width) (mm) 600 - Flame Retardancy Flame Retardant true Warranty Manufacturer warranty Period (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 Spare part availability YES - standards and certifications Comply with International Standards true Name of International standards USFDA - FDA approved true - Conformity to ISO 80601-2-69:2014 of the Medical Electrical Equipment – Part 2-69: Particular requirements for basic safety and essential performance of oxygen concentrator equipment Yes - Availability of test report CE or EC certification (to be furnished by Seller to Buyer on demand) in accordance with Appendix II(excluding section 4) of medical device directive 93/42/EC & its amendment or equivalent true - Availability of Test Report(To be furnished by Seller to Buyer on true - 3/5 demand) from Central Govt/NABL/ILAC accredited lab to prove conformity to specification Test report number and date - - Name and address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dontamsetty Chandrasekhar N 500052 | - | - | - |
| Shivarampally | - | - | - |
| Rajendra nagar | - | - | - |
| Hyderabad 1 20 | - | - | - |
Exempted
31 Jul 2018
10 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_313142.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .