EE construction Division PWD B and R Moga
EE construction Division PWD B and R Moga
Construction of Sub Tehsil at Smalsar Tehsil Baghapurana
2026_CEPW_157757_1
Bid no. 37 dated 09.01.2026
Open Tender
Civil Works - Buildings
180 days
Moga
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹3.0 L
Yes
13 Feb 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
Civil Work Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. and Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.
Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey- First Floor
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block- For first floor
Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block- For Second floor
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.
Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey-For First floor
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey- First floor
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.0 works, where not including in the complete rate of RCC including bending and binding placing in position complete
Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19-For first floor
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
Conglomerate floor 40mm thick cement concrete topping 1:2:4.
10mm thick Cement Plaster 1:4
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-First floor
Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-Second floor
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 12mm to 15mm, Slabs sizes above 0.50 sqm
Providing and laying polished Granite stone 18mm thick in flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Extra labour for projected nosing of stair case of any shape and design.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position. (Code IS 2022-1(1999)). 35mm thick
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge 4mm thick ACP Sheet
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge.
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect.
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc.
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Extra for every additonal storey for flooring-For First Floor
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Applying priming coat with metal primer on new steel or iron work including preparation of surface
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm hick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Chil wood wrought planed and fixed in position
Providing and fixing commercial plywood 12mm thick
Providing and fixing commercial plywood 18mm thick
Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra)
Providing and fixing teak wood beading to door windows chowkats with iron screws fixed in position complete as per design and shape required
Spirit polishing two coats including a coat of wood filler on wood work
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.0 works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing and laying flamed finish Granite stone 18mm thick in flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Construction of Embankment with Good Quality Earth obtained from Borrow pits Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications
Construction of granular sub-base by providing material as per grading-III (Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code -15568(2006).
Providing and laying facory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm anf top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H Specifications
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Public Health work
Sub work-1
Sub head-1 Internal Sewerage System
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B
110mm o/d single socket SWR UPVC pipe lines laid complete
75mm o/d SWR UPVC pipe lines laid complete
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
For 110mm o/d pipes
Door Cap
Door Elbow 90 Degree (All side socketed) door bend 110mm
coupler
For 75mm o/d pipes
coupler
P Trap/Floor Trap 75mm x 75mm
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty
Sub head-2 Internal Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 16mm o/d
CPVC SDR 11 Pipe & fitting 20 mm o/d
SDR 11 CPVC pipes & fittings 25mm o/d
SDR 11 CPVC pipes & fittings 32 mm o/d
CPVC SDR 11 Pipe & fitting 40mm o/d
CPVC SDR 11 Pipe & fitting 50mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.
Size 75 mm x 75 mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
Union 15 mm o/d complete
Union 20 mm o/d complete
Union 25 mm o/d complete
Union 32 mm o/d complete
Union 40 mm o/d complete
Union 50 mm o/d complete
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
20 mm i/d Brass Ball valves
32 mm i/d Brass Ball valves
Sub head-3 Sanitary Fixtures & CP Brass Fittings
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI
Providing and fixing in position Chinawareextended wall mounted E. W.C. type suite(size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing and fixing in position Metropole flush valve push type 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing &Fixing in position C.P. Brass Hexa Nipple 15mmofapprovedmake(tothe approvalofEngineer-in- charge)completein all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge)consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 49 cm dia (above counter round)
Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.(Vitreous chinaware standard white pedestal for wash hand basin.)
PProviding & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.
PVC tube connection of size 15 mm x 375 mm with PTMT nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect.
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass towel Rails size 15mm dia 610mm long
C.P brass towel ring
Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect.
C.P. brass toilet paper holder
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body foam flow without flange
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect
Providing & Fixing in postion stop cock /Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm stop cock Male and female end
C.P.brass 15mm Concealed stop cock with flange.
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock with Wall flange
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass soap dish holder with glass dish
C.P. brass toilet roll holder with flap
C.P. Glass Shelf 600mm long
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
C.P. Brass khunti with 3 pegs
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball32mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect.
Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Sub head-4 Flooring and wall tile
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
ColouredGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coa rsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps.
Sub head-5 Dranking Water cooler , RO ,And Air conditioning
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size
Automatic Voltage Stablizer 2 KVA
Automatic Voltage Stablizer 4 KVA
Automatic Voltage Stablizer 5 KVA
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Supply and installing and commissioning og BEE 5 Star Split AC 1 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Supply and installing and commissioning og BEE 5 Star Split AC 1 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Supply and installing and commissioning og BEE 5 Star Split AC 2 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing Laying hard soft copper concealing of coper pipes of various dia as requiement and eall thickness 0.8 mm,insulated/taping laying in chase cutting of wall and repairing thr same within the buikding and chages complete in all respects.
For 1.0 Tonne Split
For 1.5 Tonne Split
For 2 Tonne Split
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.Total
For 1.0 Tonne Split
For 1.5 Tonne Split
For 2 Tonne Split
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
Sub work-2
Sub head-1 Tube Well 150 mm dia and 165
Boring with casing pipe for tubewell in allsoils except ordinary hard rocks requiring blasting including removing the casing pipeafter the tube well is lowered & tested ,equipment as requried such as hand boring machine and its accessory, transportation tosite and vice versa etc. Complete in all respect.
Extra for boring beyond 150 mtr. Depth (CSR – 28.73)
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
150 mmnominal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore.
150 mm Steel Strainer (slot size 0.15/0.20mm) 5.00 mm thickness
Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
150mm internal diameter (weight 21.6 kg per metre) 5.4mm thickness
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 150 mm internal diameter
Supplying at site Wooden Box of suitable sizewith Lid & locking arrangment for preserving strata sample collected from the bore.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. Capacity of Air compressor 550 cfm at 600 PSI
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer- incharge
Collection of water sample from differentstrata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Providing & fixing Sanitry Seal as per BIS 2800:2019
Sub head-2 Pumping Machinery ,CI Fitting and Cholrinate
Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 105 LPM against a head of 59 mtr along with electric panel board consisting of electrical appliances DOL. starter, Mainwitch, VM, AMpere Meter, ELCB, Shunt capacitor.Single phase, preventer, Indicating lamps, Kit-Kat etc, including GI column Pipe of IS 1239- 2004 medium class size 40 mm and Length41 mtr.(in 3mtr lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 55 Mtr. Length and 2.5mm2 size as per IS694- 1990 reaffirmed 2000 complete in all respects
Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. Cholrinator
Prov. & Instaling, testing & commissioning one No Electronically actuated, Diaphram Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 liter of Bleaching Powder solution /Sodium Hypo soiution per our under maximum delivery pressure up to 7 Kg.cm 2, and suction lift not less than 1.5 m,as per DWS stanard specifications.
Sub head-3 Estate Water Supply system
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 63mm o/d pipe of 6 Kgf. / sqcm
P/F and jointing CPVC Union couplings with UPVC pipe complete in all respect 50mm i/d CPVC Union
Providing & Fixiing C.I indicating plates of size 100mm x 100 mm for SV/FH including synthetic enammel paint & letters in white enamel paint, fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including conrete block complete in all respect as directed by Engineer-in-charge
Sub head-1 Estate Sewerage System
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110mm o/d pipe
160mm o/d pipe
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and aintenance of caution boards, fencing, refilling trenches, watering, ramming and estoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and aintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Cement concrete 1:4:8
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Cement concrete 1:2:4
Floating coat of 1:5mm thick neat cement laid in one operation to the topping
12.5 mm thick cement plaster 1:3
Cement rendering on plaster 1mm thick
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
Sub Head -2 Providing Saptic Tank 3mX2m X 1.2 m working depth for sewer disposal.
Providing Saptic Tank 3mX2m X 1.2 m working depth for sewer disposal. & soak pit 2.5 m outer dia 3.0 mtr deep
Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design.
Sub Work-1 Fire fighting System
Providing and fixing of FIRE EXTINGUISHER, ABCPowder type (stored pressure) asper IS:15683 completewithall accessories as per Manufactures Specification. ISI Mark complete in all respect.6 Kg. Capacity
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4.5 Kg. Capacity
Electrical work
Internal E.I. Services
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Networking socket point RJ45 (one module)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Wiring light point with double control switches.
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1 sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 50sq.mm (3½ Core) Un-armoured (Loose)
HEAVY GAUGE WELDED CONDUIT PIPES:
Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed)
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
PVC Flexible Pipe 25mm dia.
8 SWG COPPER EARTHING :
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
COPPER EARTHING (Upto 14 metre in Length):
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
COPPER EARTHING STRIP (As Additional Length):
Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
Additional Length 20mm x 3mm thick Copper Tape
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
SUPPLY AND ERECTION OF WIRING ACCESSORIES:
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
Ceiling Rose (Flush Piano type)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Horizontal Double Door Distribution Board 6 way each
TP&N Horizontal Double Door Distribution Board 8 way each
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for TPN 6 Way
Cable End Box for TPN 8 Way
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):
LT PANELS:
Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.
The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.
LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm)
MCCB's (FOR PANELS & SHEET ENCLOSURE):
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure):
Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
On Load Change Over Switch Four Pole 125amp., 415volts
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Aluminium thimble cable Core size 25 -35sq.mm
Aluminium thimble cable Core size 50sq.mm
Supply and erection of LED batten 10watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary
Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 12watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of LED Recessed downlighter 6watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Surface mounted 36/40watt LED 1x4 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of venti Air fan 225/230mm with aluminum louver shutter longer lift including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should confim to technical specifications attachted.
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee/warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Cost of LAN Networking System
Supply, installation, testing and commissioning of 24 Port L2 managed 10/100/1000 Mbps Data switch with 4 No Uplinks RJ45 and SFP Combo 1G Ports • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 50 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), • IEEE 802.3af • IEEE 802.3at . CPU RAM 256MB or above Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F) Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, installation, testing and commissioning of CAT 6 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination, ID Plate PC transparent color with paper, Panel: SPCC,1.5mm thickness with black color painted, RJ45 Jack- Housing: P B T + g la ss fiber, UL-94V-0 Contact Brackets: PBT + glass fiber, UL-94V-0, RJ45 Jack Contact- Material: Phosphor bronze with nickel plated Finish: 50 micro-inches Gold plated on plug contact area, IDC Housing: PC, UL 94V-0 Terminal: phosphor bronze with tin plated, e ANSI/TIA/EIA 568C.2 & ISO/IEC 11801 standard..Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, installation, testing & Commissioning of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps Conductor: 24 AWG, Multi-strands Conductor Metal: Bare Copper Insulation Material: HD-PE Material: FR-PVC s TIA/EIA 568C.2 standard ISO/IEC 11801 Class EA. Gold Plated: 50U° Contact Blade: Copper Alloy Dielectric withstanding voltage: 1000V DC/min, 500M Ù, 1000V DC/min UL Applications: PC UL94-V-0 Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply & erection of 12U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respect as desired by the engineer in charge at site.
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:
Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
CAT 6 LAN cable
Supply & erection of 1KVA/800Watt 36VDC Online UPS with In- Built 3 No. Batteries Pure Sine wave with following features OVCD Wide input range Programmable output range 208V/220V/230V/240V 12V x 7Ah x 3 No. SMF batteries in-built Output Power Factor 0.9 0ms Transfer time from Inverter Mode to Battery Mode Charger Current 1.5 Amp Cooling Fan True Online Double Conversion Inbuilt Over-voltage Cut-off Device Inbuilt Over Temperature Protection Surge Protection Better Overload Protection upto 105% Constant Higher Efficiency up-to 92% in ECO Mode 2 year onsite warranty on UPS 30+ minutes Back up time on switches load complete in all respect as desired by the engineer in charge at site.
Cost of CCTV Surveillance System
Supply & erection of Bullet FIX Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8" SONY - CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux Focal Length-3.6/2.8/4mm, Focus Range - 0.3m to infinity, Field of View (FOV)Minimum-HFOV – 87.6° VFOV – 46.4° DFOV – 104.5° Focus-Fixed focus Aperture (F#) F 1.6 / F 2.0,Iris Type Fixed, IR Range Up to 50m, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μ Alarm In Yes, Alarm Out Yes,SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dB Image Enhancement Saturation/ Contrast/ harpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-4 .0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentic tion Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (noncondensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part-15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X**,- complete in all respect as desired by the engineer in charge at site.
Supply & erection of Dome FIX Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8" SONY - CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux Focal Length-3.6/2.8/4mm, Focus Range - 0.3m to infinity, Field of View (FOV)Minimum-HFOV – 87.6° VFOV – 46.4° DFOV – 104.5° Focus-Fixed focus Aperture (F#) F 1.6 / F 2.0,Iris Type Fixed, IR Range Up to 50m, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μ Alarm In Yes, Alarm Out Yes,SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dB Image Enhancement Saturation/ Contrast/ harpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-4 .0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentic tion Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (noncondensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part-15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X**,- complete in all respect as desired by the engineer in charge at site.
Supply & Erection of 16 Channel IP INPUT 12MP NVR 4K with 4 SATA having following features:- Up to 16 Channel Input, 4 Sata Interfaces, Up To 12TB each, H.265+/H.265/H.264 Video Formats, 2 HDMI Port,1 VGA, USB3.0*1, USB2.0*2 Support,2×RJ45 Self-adaptive 10/100/1000 Mbps Network Interfaces, Supports live view, storage and playback of the connected camera at up to 12MP resolution, Connectable to the Third Party Network Cameras, Incoming Bandwidth -320M, Outgoing Bandwidth-320M, Recording Resolution-12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p, Recording Compression, Audio: G.711a,G.711u, Video : H.264/H.265, H.264+/H.265+, Speed -12MP:30fps 8MP:120fps 4MP:240fps 2MP:480fps, Playback- 1080P:480fps Max 16CH, WEB -IE10/11, Safari V12.1 above, Firefox V.52 above, Google chrome V.57 above, Edge V.79 above, Protocols-TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, UPnP, HTTP, HTTPS, API -Onvif (profile S/G/T), VGA- 1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080 ), HDMI -1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 2560*1440(2K), 3840*2160(4K)) 1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080 /EDID) Async out, Ethernet-2 RJ45 100/1000 Base-T USB USB2.0*1(front), USB3.0*1 USB 2.0 *1 (rear), Audio-1 in / 1 out, E-sata-1 ,HDD 4, each up to 12TB, RS 485-1, Alarm Input/out -16 in /1 out, OSD LanguageEnglish, Input Voltage/ Current 12V/5A, Power consumption (excluding hard disk) -8W Operating Temperature/Humidity-Temperature :-10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH complete in all respect as desired by the engineer in charge at site.complete in all respect as desired by the engineer in charge at site.Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply & Erection of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL for NVR recording and playback complete in all respect as desired by the engineer in charge at site. complete in all respect as desired by the engineer in charge at site. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply & erection of Smart 32” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) Samsung TV Plus App USB Cloning, 2 No. Of HDMI Port 2 no USB Port complete in all respect as desired by the engineer in charge at site.
SITC of 24 Port POE 190+ Watts L2 managed 10/100/1000 Mbps Data switch with with 4 No Uplinks RJ45 and SFP Combo 1G Ports • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 50 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af • IEEE 802.3at PoE-capable Ports • Ports 1 to 8 Power 60W • 360 W (30 W max. per PoE port). CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F) complete in all respect as desired by the engineer in charge at site.
Supply, installation, testing and commissioning of CAT 6 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination, ID Plate PC transparent color with paper, Panel: SPCC,1.5mm thickness with black color painted, RJ45 Jack- Housing: P B T + g la ss fiber, UL-94V-0 Contact Brackets: PBT + glass fiber, UL-94V-0, RJ45 Jack Contact- Material: Phosphor bronze with nickel plated Finish: 50 micro-inches Gold plated on plug contact area, IDC Housing: PC, UL 94V-0 Terminal: phosphor bronze with tin plated, e ANSI/TIA/EIA 568C.2 & ISO/IEC 11801 standard..Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, installation, testing & Commissioning of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps Conductor: 24 AWG, Multi-strands Conductor Metal: Bare Copper Insulation Material: HD-PE Material: FR-PVC s TIA/EIA 568C.2 standard ISO/IEC 11801 Class EA. Gold Plated: 50U° Contact Blade: Copper Alloy Dielectric withstanding voltage: 1000V DC/min, 500M Ù, 1000V DC/min UL Applications: PC UL94-V-0 complete in all respect as desired by the engineer in charge at site
Supply & erection of 10 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respect as desired by the engineer in charge at site.
COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:
Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
CAT 6 LAN cable
Cost of Security & Campus Lighting
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (48/0.20mm), 3Core
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 10sq.mm (2Core) Un-armoured (Loose)
Overall size 16sq.mm (2Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
GALVANIZED IRON PIPES AND G.I. EARTHING
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
GI Earth rod 20 mm dia., 3 mtr. Long
8 SWG COPPER EARTHING :
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 8 way each
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):
Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:-
Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
AUTOMATIC VOLTAGE STABLIZER, TIMER:
TIMER:
Street Light Controller (For Single Phase Circuit) with 1 No. Three Pole Power Contactor 40A, 1 No. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 1 No. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
3-STEPPED STEEL TUBULAR POLE (WITH PRE-CAST FOUNDATION):
Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix on precast RCC column of suitable dimensions. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The steel tubular pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level including painting of pole with two coats of approved aluminium paint as required:-
Overall length 7 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2), Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick (approx. weight 7.235 kg.)
SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:
Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-
Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m)
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS:
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double walled corrugated (DWC) HDPE pipe 50 / 38mm (outer/inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Aluminium thimble cable Core size 10 - 16sq.mm
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
CUBICAL PEDESTAL:
Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm
Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Cost of On Grid Solar Power Generating System of 5kw
Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 5KWp including required quantities of SPV modules (High power density Monocrystalline based single module iof capacity+550W) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Chemical copper bonded rods (i.e. 1 Nos. GI Structure, 2Nos. for String Inverter, AC & DC Distribution System)Provsion of Lighting arrester and 2 Nos. G.I. chemical earthing with copper bonded rods. Hot Dip Galvanized MS Mounting Structure be Designed to with stand the Speed for the Wind Zone of the Location(Rated Wind Speed 150-170Kph) Complete with transportaion, fabrication, labour & Civil Work. Features:-
1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 1&2 IS/ IEC 61701 & IS/IEC 14286 & IEC 61215, BIS Certificates & MNRE, GOI latest specifications / Standards. 2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1,IEC / EN 62102-2 , EN 61000-6-2, EN61000-6-3, IEC61683, EN 50530 , IEC 60068-2-1,2,14,30,EN 60529, IES 60947 Part 1,2,3 IS 60947 Part 1&2 , IES 60227/IS 694,IES 60502/IS 1554 BIS Certificates & MNRE, GOI latest specifications / Standards. 3. Structure : 25 Years Service Life with AMC & Certified under IS 2062:2011 4. Complete Plant Insurance for the period of 10 Years (Excluding Theft of the material) 5. Annual Maintenance Contarct for the period of 10 Years Conditions:- 1. The Plant will be installed as per MNRE and GOI guidelines specifications.(Detail of Material as per Annxeure -1 Attached) 2. The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) Contractors.PWD enlisted contractor subject to condition that PWD Enlisted contractor will get work done from MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) approved Conractors. The Rates are inclusive of Bi-directional meter testing charges, PSPCL Connection Charges, Unidirectional meter cost and all type of taxes including GST
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_319885.xls
BOQ • 0.58 MB
SBD.pdf
Tender Documents • 14.76 MB
Download all tender documents and submit your bid