Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC 0 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹25.9 L+₹1.9 L (7.82%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-Finance Highest bidder | |
| 3 | L3₹25.9 L+₹1.9 L (7.98%)Rejected-Finance | L3 | Rejected-Finance Highest bidder | |
| 4 | L4₹25.9 L+₹1.9 L (8.12%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L4 | Rejected-Finance Highest bidder | |
| 5 | L5₹26.1 L+₹2.1 L (8.68%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Highest bidder |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
31 Aug 2020, 6:00 pmClosed
GE AF Bamrauli
GE AF Bamrauli
SPECIAL REPAIR REPLACEMENT TO HANGAR LIGHTS WITH LED LIGHTS IN DJ COMPLEX AND HANGER NO 01 AND 02 AND CERTAIN SANCTIONED WORKS UNDER GE AF BAMRAULI
2020_MES_367152_1
8594/E8
Open Tender
Civil Works
Item Rate
180 days
Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Bamrauli
₹47,000
Yes
28 Sept 2020
6 Aug 2020
2 Sept 2020
6 Aug 2020
31 Aug 2020
26 Aug 2020
Amount
M & L for Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FR, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed. Note:- (a) Two runs of 6.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S & F factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42),vertical type suitable for mounting isolater, MCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar ,SP and N 12 ways, 240 volts complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens Note: MCB shall be measured and paid seperatly under respective item of this schedule
S&F MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens
S&F MCB, single pole and neutral, 230 volts, 32 to 63 Amps rating, "C" series complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens
S&F LED flood light fitting high way 150 watt with surge pretection 4 KV inbuilt and minimum 10 KV separate, IP 66 having pressure die cast aluminium housing with heat resistent toughened glass individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for sustain 440 volt for 2-4 hour complete all as specified and directed. Note :- (i) LM-79 and LM-80 test report with 50000 burning hours LED life from NBAL lab shall be provided. (ii) CRI (Colour rendering index of fixtures shall be greater then 70. (iii) System lumen efficiancy shall be 150 lumen/watt complete all as specified and directed. Make : Phillis/Havells/Wipro/Syska
S&F LED flood light fitting high way 200 watt with surge pretection 4 KV inbuilt and minimum 10 KV separate, IP 66 having pressure die cast aluminium housing with heat resistent toughened glass individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for sustain 440 volt for 2-4 hour complete all as specified and directed. Note :- (i) LM-79 and LM-80 test report with 50000 burning hours LED life from NBAL lab shall be provided. (ii) CRI (Colour rendering index of fixtures shall be greater then 70. (iii) System lumen efficiancy shall be 150 lumen/watt complete all as specified and directed. Make : Phillis/Havells/Wipro/Syska
Supply, fix,testing and commissioning of 05 KVA UPS with two hour backup sine wave invertor,rated power 4250 watt,supports including suitable Nos of battry of 12 volt 150 AH maint free tubular SMF .Make of battry Exide, Luminous, Amron. safe for sansitive appliances with sine wave output , auto overload handling capacity comprising MCB for protection from input mains,inbulit microprocessor comprehensive battry charging control system technology , maximum charging current 12 Amp, 5000 VA rating, single phase in single phase out, indication lamp, LCD display Unit displaying load level, battry level, AC mode, battry mode,bypass mode, fault indicator complete with wiring with suitable size wire in conduit /casing caping with existing system complete all as specified and directed. Make: UTL,Warrie, microtek,luminous, (i) Supply and fix angle Iron movable wrack comprising air vent,front and back opening door and locking arrangement,suitable space for maintenence for housing battry . The specification of UPS is as under :- (a) Digree of protection -IP-42. (b) Overall efficiancy -90% (c) Protection for under voltage, under voltage, short circuit. Note - Company certified test certificate is mandetory.
Supply, fix,testing and commissioning of 20 KVA UPS for two hour backup sine wave invertor,rated power 175000 (17.5KW) watt, including suitable Nos battry of 12 volt 150 AH maint free SMF, safe for sansitive appliances with sine wave output ,three phase in three phase out, auto overload handling capacity comprising MCB for protection from input mains,inbulit microprocessor comprehensive battry charging control system technology , maximum charging current 20 Amp, 2000 VA rating ,indication lamp , LCD display Unit displaying load level,battry level,AC mode, battry mode,bypass mode, fault indicator complete with wiring with suitable size wire in conduit /casing caping with existing system complete all as specified and directed. Make : UTL,Warrie, microtek,luminous. Including following item (i) Supply and fix angle Iron movable wrack comprising air vent,front and back opening, locking arrangement,suitable space for maintenence for housing battry. The specification of UPS is as under :- (a) Digree of protection -IP-42. (b) Overall efficiancy -90% (c) Protection for under voltage, under voltage, short circuit. Note - Company certified test certificate is mandetory.
S & F factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42),vertical type TPNDB suitable for mounting MCCBS, MCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar ,TP and N 8 ways ,415 volts complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens Note: MCB/MCCBs shall be measured and paid seperately under respective item of this schedule
Supply and fix MCCB, three pole, 415 Volt ,125 Amp rating, 35 KA complete all as specified and direted.
Supply and fix MCB, SPN 63 Amp 10 KA, 230 Volt , 50 Hts 'C' series complete all as specified and direted.
M & L for Sub main wiring with 4 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 10 sqmm FR, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed. Note:- (a) Two runs of 10 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Earthing complete with Copper earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 20x3 copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 25 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth copper strip and GI pipe for protection of earth strip. Any varriation in quantity shall be adjusted.
Supply and fix copper strip of size 20x3 mm on epoxy based insulator duly fixed with suitable size nuts and bolts on wall complete all as specified and directed.
Supply and laying 16 sqmm single core multistranded, PVC insulated copper conductor cable as earth continuty from strip to highly sensitive equipment which reqire zero voltage in neutral to earth complete all as specified and directed.
Supply and fix test point terminal block made of gun metal or phosphorous bronze size 75x75x25 mm drilled and screw including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Excavation in trenches in soft/ loose soil not exc 1.5m wide and not exceeding 1.5m in depth for laying of cable, errection of poles,stay and pipe line, complete all as specified and as directed.
Excavation in trenches in hard dense soil not exc 1.5m wide and not exceeding 1.5m in depth for laying of cable, errection of poles,stay and pipe line, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated surplus materials to a distance not exec. 50m and deposing where directed at a level not exc. 1.5m above the starting point all as specified and directed.
M&L for sand in trenches and spreading in layers for cable cushioning complete all as specified and directed.
M&L excavation in trenches by cutting/ removal of interlocking tiles, PCC hard standing for taking out / laying of pipe including making good the existing surface with PCC and refixed interlocking tiles to match the original finish all as specified and directed.
M&L for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable, complete all as directed.
M&L for steel tubes, light grade galvanised of 80mm bores and in trenches and spreading for cable protection/earth strip protection with all fixing accessories etc complete all as specified and directed.
M&L for earthing complete with Galvanised earth plate electrode 600x600x6mm thick buried directly in ground (earth) pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel of size 75mm x 75mm x 25mm, supplying and laying charcoal stone aggregate) chamber and mild steel angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia TMT BARS @ 75mm O/O both ways with mild steel handle 12mm dia, PGI funnel with wire mesh, 20 MM dia GI pipe light grade for watering all as shown in electrical plate No.3 of MES SSR Part - 1
Supply and Fixing of ON load change over switch 4 pole, 415 Volt, AC, 50 Hz of capacity 160 Amps with sheet metal enclosure and fixing on panel/wall by the help of nuts and bolts and all electircal connection complete all as specified and directed. Make:-Havells/Standard/Indoasian
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/S VIJAY SINGH
M/s Techno India and Company
Avion Industries
Mohit Enterprises
M/S V K MEHROTRA
R K CONSTRUCTION COMPANY
R.K.ASSOCIATES
M/S R S Traders
M/S Aquarius Construction
M/S SATISH KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .