Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.5 LAccepted-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹23.1 L+₹49,852 (2.21%)Rejected-AOC | L-2 | Rejected-AOC Other than L-1 | |
| 3 | L-3₹23.8 L+₹1.2 L (5.10%)Rejected-AOC | L-3 | Rejected-AOC Other than L-1 | |
| 4 | L-4₹24.8 L+₹2.2 L (9.68%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L-4 | Rejected-AOC Other than L-1 | |
| 5 | L-5₹27.2 L+₹4.6 L (20.2%)Rejected-AOC | L-5 | Rejected-AOC Other than L-1 |
Tender Value
₹25.3 L
EMD Value
₹50,600
Closing Date
4 Nov 2024, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-76/2024-25 REPAIR/ MAINT OF 2 MW SOLAR POWER PLANT UNDER GE (U) CHANDIMANDIR AT CHANDIMANDIR MIL STN
2024_MES_678599_1
CWE/CHM(U)-76/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (U) Chandimandir
Class D Cate b(i)
9 documents required · 9 mandatory
₹500
GE (U) Chandimandir
₹50,600
21 Dec 2024
8 Oct 2024
6 Nov 2024
8 Oct 2024
4 Nov 2024
21 Oct 2024
8 Oct 2024 - 12 Oct 2024
Amount
S&F in replacement of solar photo voltaic module panels 330 Wp, rated voltage 37.67 V, rated current 8.79 Amp, crystalline silicon PV modules with spare parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting including taking down old broken/ unserviceable module all as per site requirment complete all as specified and directed by Engineer-In-Charge.
Repair/ Servicing of On grid inverter outdoor type including replacement of unserviceable parts, IP-65 protection, 60 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, AC power string inverter on three phase side output voltage 415 V (+12.5%, 20% VAC) maximum current ripple 4% PP, Reactive power 0.95, inductive to 0.95 capacity, harmonic distortion less than 3%, over all efficiency of not less than 98% and above at full load with all protection (IEC-61683), Operating temperature range 20 Degree Celcius to 60 Degree Celcius including making connection as per existing complete all as per site requirment all as specified and directed by Engineer-In- Charge. Note: The cost of replacement of unserviceable parts shall be measured separately under item no. 2.01 to 2.04 here-in-after.
DC Relay
Boosting Capacitor
EMI Filter
Supply and fixing in replacement of Kiosk box, made out of fibre material complete with TPN, aluminium busbar suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & outgoing cable including fixing of flat iron clamps of size 20 x 4 mm on PCC/ Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/ Sintex or equivalent make as aproved by GE.
Trimming of Tree branches along the solar panels and fencing, maintaining minimum clearance of 3 Metre from Panels at a height of 2.5 mtr above ground level upto tree height and ensuring no shadow falls on panel from 0800 Hours to 1900 Hours complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of Integral LED Street light Luminaries, 60 Watts capacity, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and as directed by engineer-in-charge.
Supply and fixing in replacement MCCB, TPN, 125 Amps, 415 Volts, 16 KA, Ics=100% Icu, with adjustable thermal and adjustable magnetic release including complete connection all as specified and as per direction of Engineer-in-Charge.
Supply and fix in replacement of on grid inverter outdoor type, IP 65, with minimum 60.00 KW (matching with PV panels output) AC nominal rating (Array to Inverter Ratio 1:1), 3P, 50Hz AC power string inverter on three phase side: - Output voltage 415 (+12.5%, -20% VAC), frequency 50Hz (+3 Hz, -3Hz) Maximum current ripple 4% PP, Reactive power 0.95 inductive to 0.95 capacity, total harmonic distortion: less than 3% with overall efficiency of not less than 98% and above at full load. (IEC-61683) with all protection and controlling as per specification including suitable communication portal with SCADA for monitoring all parameter like P, PF, V, I etc (with in built or external data logging device and on line portal log-in ID and password) complete all as specified and as directed by Engineer-in-Charge. Make : SMA SUNNY TRIPOWER 60 or euivalent make as approved by GE.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, for under ground cable/ erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/ trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and as directed by Engineer-in-charge.
Removing excavated material/ soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: Only punned thickness of sand will be measured and paid.
Supply and laying well burnt bricks sub class "B" old size for cable protection laid flat lengthwise perpendicualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc. complete all as specified and as directed by Engineer-in-charge.
Supply, laying, connecting and testing underground cable, of cross sectional area 10 sqmm, 4.0 core, XLPE insulated, overall sheathed with aluminium conductor, heavy duty 1100 volts grade, including Al thimbles laid in trenches/ on pole/ road crossing or passing through existing/ new pipe under road crossing clamping on wall etc. Note : (i) Earth work, sand, bricks will be measured and paid seperately. (ii) Cost of laying electrical cable through new/ existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments, machinery or tool if required for laying electrical cable through new/ existing pipes are provided by the contractor without any extra cost.
All as per serial item No 16.00 here-in-before but of cross sectional area 16 Sqmm, 4 core.
All as per serial item No 16.00 here-in-before but of cross sectional area 35 Sqmm, 3.5 core.
All as per serial item No 16.00 here-in-before but of cross sectional area 95 Sqmm, 3.5 core.
All as per serial item No 16.00 here-in-before but of cross sectional area 150 Sqmm, 3.5 core.
All as per serial item No 16.00 here-in-before but of cross sectional area 400 Sqmm, 4 core.
Material and labour for shifting heavy items/ excavation/ cleaning areas/ cleaning site by providing crane/ hydra/ excavators/ tractors/ trolley etc. as required at site complete all as specified and as directed by Engineer-in-charge.
Material and labour for spraying herbicide (Round up) on area to remove unwanted vegitation/ grass at various locations as directed by Engr-in-Charge. Note:- 1. there should be no vegitation growth in the sprayed area within 30 days of spraying. 2. contrator shall repeat the spray with no extra cost to government, if vegitation growth is seen on the sprayed area within 30 days.
Supply Only PVC braided hose pipe size 01 Inch complete all as specified and as directed.
supply and fixing GI Steel water tubes, of size 20 mm bore, ISI marked, medium grade with all fittings such as bends, elbows tees, pieces, connections, back nuts, diminishing pieces caps, plugs and unions etc, laid in trenches including taking out of old unserviceable GI pipes complete all as spcified and as directed by Engineer-in-charge.
All as per Serial Item No 25.00 here-in-before but of size 25 mm bore.
All as per serial Item No 25.00 here-in-before but of size 50 mm bore.
supply and fixing GI Steel water tubes, of size 20 mm bore, ISI marked, medium grade with all fittings such as bends, elbows tees, pieces, connections, back nuts, diminishing pieces caps, plugs and unions etc, laid on floor/ wall/ ceiling with clamp including taking out of old unserviceable GI pipes complete all as spcified and as directed by Engineer-in-charge.
All as per Serial Item No 28.00 here-in-before but of size 25 mm bore.
All as per serial Item No 28.00 here-in-before but of size 50 mm bore.
S&F in replacement Gun metal globe or gate valves of size 20 mm bore, ISI Marked, with iron wheel head, screwed both ends for iron pipe complete all as spcified and as directed by Engineer-in-charge.
All as per Serial Item No 31.00 here-in-before but 25 mm bore.
All as per Serial Item No 31.00 here-in-before but 50 mm bore.
Supply and fixing in replacement Rotational moulded polyethelene water storage tank, triple layer, ISI marked, of capacity 2000 litre (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, with inlet & outlet connections to existing pipeline with all fittings such as GI tank nipple 150 mm long with washer & plug etc, including provision of 20 mm PTMT float/ball valve complete all as spcified and as directed by Engineer-in-charge.
Supply and fix in replacement of Lithium based Energy Efficient Integrated Solar Street Light of 32 Watt in Single FRP body with duly Polyurethane coating (Camouflage color), encases with Mono crystalline Solar PV Panel of 64/ 66Wp, Lithium Battery 11.1/12.8V, 33.0 AH with inbuilt BMS, IP 65, High brightness W-LED (160-180 lm/watt) lamp with Aluminium reflector for better light distribution, CRI >70, Color Temperature 5700°K - 6500°K, Micro controller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-)10°C to (+)55°C, weight not more than 16-18 kg with adjustable MS clamp suitable for pole/ wall mounting etc complete as required.
Serial Item No. 35 Continued.. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant including tubular pole 6 mtr height with bottom base plate 200 x 200 x 12 mm, outdoor dia not less than 65 mm with heavy duty GI pipe or steel thickness 3mm and suitable arrangement to mount solar light as directed on pole including foundation PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) and erection as per manufacturer drawing, providing synthetic enamel aluminium paint over one coat of red oxide complete all as specified and directed by Engineer-in-charge.
Material and labour in replacement of broken earth pit of size 300 x 300 x 300 mm made of PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates), and earth pit cover made out of RCC 1:2:4 type B-1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of Surge protection Device (SPD), DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of DC Fuse, 15 Amp in Surge protection Device (SPD), DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Surge protection Device (SPD), AC in AC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
M&L for loose filling in of hard core broken to gauge not exc 63 mm broken stone/ boulders in substations for preventing the vegetation, including leveling and spreading lime stone powder under stones complete all as per specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC insulated Solar DC cable, copper conductor, 6 sqmm, 1.8 KV, DC volt for solar plant complete all as per specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of cable connector for solar DC cable 6 sqmm 1.8 KV DC volt for solar plant complete all as per specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised earth plate electrode 600 mm x 600 mm x 6.00 mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25 x 4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40 mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ, the earthing will be re-done at no extra cost.
Material and labour for Earthing complete with galvanized steel plate earth electrode 60cm x 60cm x 6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing including taking down old u/s earthing complete all as specified and directed by Engineer-in-charge.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost
Earthing complete with copper earth plate 600 mm x 600 mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 20x3 mm Copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion including taking down old u/s earthing complete all as specified and directed by Engineer-in-charge.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost.
Supply and fixing in replacement Copper strip 20 x 3 mm from earth electrode to test point complete all as per specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement GI earth strip 25 x 4 mm from earth electrode to test point complete all as per specified and as directed by Engineer-in-Charge.
Supply only Telescopic Wiper 9 m long for cleaning of solar panels complete all as per specified and as directed by Engineer-in-Charge.
MANSA ENTERPRISES (BID ID -3152198)
M/S RAGBIR ENGINEERING SERVICES (BID ID -3156705)
R D Bansal (BID ID -3156853)
Nirmal Enterprise (BID ID -3157277)
Bharat Enterprises (BID ID -3151179)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .