Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | ₹11.4 L | L1 | Accepted-AOC DUE TO L1 BIDDER |
| 2 | L2₹12.2 L+₹78,395 (6.87%)Rejected-AOC | ₹12.2 L+₹78,395 (6.87%) | L2 | Rejected-AOC DUE TO NOT L1 BIDDER |
| 3 | L3₹12.4 L+₹99,236 (8.70%)Rejected-AOC VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | ₹12.4 L+₹99,236 (8.70%) | L3 | Rejected-AOC DUE TO NOT L1 BIDDER |
| 4 | L4₹12.5 L+₹1.0 L (9.15%)Rejected-AOC | ₹12.5 L+₹1.0 L (9.15%) | L4 | Rejected-AOC DUE TO NOT L1 BIDDER |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
18 Mar 2020, 6:00 pmClosed
GE ARMY BARMER
GE ARMY BARMER POST BOX NO 53 JALIPA MIL STN BARMER 344001
REPAIR MAINTENANCE OF EXTERNAL SUPPLY LT UG CABLE EARTHING LT POLES AT MIL STN JASSAI UNDER GE ARMY BARMER
2020_MES_316001_1
GE(A)/BMR-53 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹24,000
Yes
5 Jun 2020
18 Jan 2020
21 Mar 2020
18 Jan 2020
18 Mar 2020
1 Feb 2020
Amount
S&F inreplacement of guard wire / cradles rectangular, fabricated with Galvanised steel wire 3.15mm or 4mm dia for guarding of LT line complet all as specified and as directed .
Dismantiling/uprooting of LT pre-stressed concrete poles /steel poles of any size and shape including taking out dismantled portion of pole embended in ground after necessary demolition of foundation concrete and making good disturded ground properly and removing the debris out sdide MD land complete all as specified and as directed. Note :- The necessary excavation & earth work is required to be included in the rate quoted.
Supply and errect steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate and finial taper plug, bolts, nuts & screws complete all as specified and directed. Note: - (i) Excavation and earthwork,PCC shall be measured and paid separately in relevant item here in after . (ii) Painting with two coats of black bituminous paint throughout internally and externally upto plating depth and the remaining external complete pole portion shall be painted with silver colour in two coats over a red oxide primer and A1 graded radium strip of 100mm width in three colour red, yellow, and green fix around the pole with 100mm gap in each strip at a distance of 1.1 mtr high from the ground level deemed to be included in quoted rates.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised iron strip 25mm x 3mm including taking down old strip complete all as specified and directed.
Dismantling of unservicable steel structure, cross arms, bracings, supports, clamps from two /four pole stucture at various location complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps,ladder and back plates fabricated from steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete all as specified and as directed .
Fixing only serviceable cross arms, bracings, supports, clamps,ladder and back plates including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts if required, in any shape or size as indicated or directed and including preparation of old steel surface and apply one coat of aluminum paint complete all as specified and as directed . Note :- Serviceable cross arms obtained from slitem No.05 of above will be re used.
S& F in repairs Lithium base energy efficient integrated solar street light 12 watt in FRP body encases solar PV panel 34/36Wp monocrystallinn, Lithium battery 11.1/12.8V,19.8 AH with in built BMS, hogh brightness W-LED (120-1401m/ watt) lamp, CRI 80, colour temperature 6500K, micro controller based charge controller cum driver with automatic dimming function, dusk to down operation, LUX output 30 -35 ( from 5-6mtr height) , working temperature (-) 10° c to (+) 55°c, weight 10-12 kg with adjustable MS clamp suitable for pole / wall mounting protection from short circuit, overload , reverse polarity and battery protections complete all as specified and as directed Make : Axxon - AXN - 12 watt or techno commercially equivalent model of make Bajaj/Philips/CG
Earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized M.S. earth strip 32mm x6mm by means of bolts, nuts, check nuts and washers of galvanized iron mild steel all as shown in Electrical Plate No. 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40mm bore light grade pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal / salt, funnel etc complete all as specified and as directed.Note : - (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in Electrical Plate No. 3 of MES SSR Part-I, (ii) Item includes the cost of GI pipe up to 7.50m for protection of earth wire/strip, (iii) Item includes the cost of earth lead wire/strip up to7.50m & (iv) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate quoted.
Trimming / cutting of tree branches, bushes obstructing the HT/ LT OH lines, making clearance at a distance of 3mtr from outer conductor of OH lines including removal of rubbish to out side MD land complete all as specified and directed .
M&L cement concrete 1:4:8 type D-2 by using 40mm graded crushed stone aggregate as in foundation of poles, stays including necessary form work complete all as specified and as directed.
M&L cement concrete 1:3:6 type C-1 by using 10mm graded crushed stone aggregate as in coping / pedestals of poles etc., including necessary form work complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable with stone slab/patti cable protection slab/cover complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable with stone slab/patti cable protection slab/cover complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable with stone slab/patti cable protection slab/cover complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable with stone slab/patti cable protection slab/cover complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable with stone slab/patti cable protection slab/cover complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, taking out cable / pipe line etc and not exceeding 10 Sqm on plan and getting out in soft / disintegrated rock complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and exceeding 1.5 mtr but not exceeding 3.00 mtr in depth for foundation of pole, taking out cable / pipe line etc and not exceeding 10 Sqm on plan and getting out in soft / loose rock complete all as specified and as directed.
Removing excavated materials(rock) to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and as directed.
Supply and spreading clean dry sand ( tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed. Note : stone patti/slab obtained under Sl item No 13 to 17 shall be reused.
Laying only 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
M&L for replacement of conventional earthing for bore earthing 150mm dia and depth 50mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 15cm C/C on both side of the pipe including lowering in bore well up to the depth of 49 mtr and one mtr above ground level . The pipe electrode should be filled around commercial salt, charcoal dust / breeze and magnesium phosphate of 30cm layer full length of pipe and the borewell should have 12 mtr of length 150mm dia MS pipe for protection of bore well including welding of GI strip 50X6mm on earth elecrode GI pipe 50mm dia up to the 20 mtr below ground level and15 mtr from the bore well to test point including necessary water connection by GI steel tubing 15mm dia and gun metal test point complete all as specified and as directed.
M&L aluminium lugs eye lid or barrel type complete with cripping/ soldering etc., including removing the worn out lugs suitable for aluminium conductor cables / copper conductor cables of sizes from 16sqmm to 35sqmm complete all as specified and as directed.
M&L aluminium lugs eye lid or barrel type complete with cripping/ soldering etc., including removing the worn out lugs suitable for aluminium conductor cables / copper conductor cables of sizes from 50sqmm to 120sqmm complete all as specified and as directed.
M&L aluminium lugs eye lid or barrel type complete with cripping/ soldering etc., including removing the worn out lugs suitable for aluminium conductor cables / copper conductor cables of sizes from 150sqmm to 240sqmm complete all as specified and as directed.
Preparation of old painted surfaces of F/P box / LT panel of any size by removing all dust, dirt etc.,and paiting with one coat of synthetic enamel paint including connected accessories of approved colour including writing of identification etc., complete all as specfified and as directed .
M&L for danger notice plate of size 25cm x 15 cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters, figures and convention skull and bones in signal red colour and fixed with MS clamps, bolts and nuts for LT complete all as specified and directed
M&L for cable double compression glands for XLPE/ PVC insulated, PVC sheathed armoured, aluminium conductor LT cable of size 120 sqmm 3.5 core complete all as specified and directed.
M&L for cable double compression glands for XLPE/ PVC insulated, PVC sheathed armoured, aluminium conductor LT cable of size 95 sqmm 3.5 core complete all as specified and directed.
M&L for cable double compression glands for XLPE/ PVC insulated, PVC sheathed armoured, aluminium conductor LT cable of size 70 sqmm 3.5 core complete all as specified and directed.
M&L for cable double compression glands for XLPE/ PVC insulated, PVC sheathed armoured, aluminium conductor LT cable of size 50 sqmm 3.5 core complete all as specified and directed.
S & F in replacement of indicator lamp LED type red,blue and yellow colour including making necessary connection in existing panel complete all as specified and as directed.
Demolition of old broken earth pit chamber and repairing the earthing chamber pit of size 450X450X300mm ( external) & 250X250X250mm ( Internal) with PCC 1:3:6 type C-1by using 20 mm graded crushed stone aggregate and 40 mm thick RCC precast cover slab of 1:2:4 type B-1by using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 100 mm C/C on both sides watering pipe, funnel mesh etc complete all as pecified and as directed .
Supply,install, testing and commissioning factory made LT feeder pillar ( Kiosk) box made out of CRCA sheet of 3.15mm thick, 200A rated, of size 0.45 x 0.45 x 0.45 mtr, outdoor canopy type, CPRI approved , floor mounted, dust and vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity screwed copper bus bar (200 Amp rating) with suitable size bolt and nuts , thimbles glands including taking out existing LT feeder pillar box complete all as specified and directed with the following accessories :- (a) MCCB 4 pole, 415 Volts, 125 Amps, 25 KA - 01 No (b) Indicator lamp (RYB) (set of three) - 01 Set.
M&L for spreading the 40mm graded crushed stone aggregate in sub station yard complete all as specified and as directed.
M&L for spreading the 20mm graded crushed stone aggregate in sub station yard complete all as specified and as directed.
M&L for stay assembly complete with 300 x 500 x 6mm thick plate and 20mm dia stay rod and stay insulators all as shown in electrical Plate No. 1 including dismantling of old stay assembly complete all as specified and as directed . Note : -Excavation & Earth work and, PCC shall be measured and paid for separately.
S&F in repairs GI stay strand 7/4.00 mm size complete all as specified and as directed
S&F loop type porcelain insulator, vitreous white, brown or green, over all dimension 90x140mm and clearance of hole 25.5mm complete all as specified and as directed.
S&F shackle type insulators, porcelain, vitreous, brown or green insulator including galvanised mild steel straps, washers, insulators, bolts, washers and nuts, working pressure 1100 volts and size of 100mm in height and 115mm dia with section of straps 31 x 5mm and dia of bolts 14mm complete all as specified and as directed .
S& F pin type, porcelain, vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanised iron washer and one galvanised iron nut, size 65mm dia x 100mm height for 1100 Volts grade complete all as specified and as directed .
S&F in replacement of GI tubing, light grade of 50mm bore , as in road crossings / laid in trenches / fixed on walls / poles etc., for cable protection complete all as specified and as directed.
S&F in replacement of GI tubing, light grade of 80mm bore , as in road crossings / laid in trenches / fixed on walls / poles etc., for cable protection complete all as specified and as directed.
Godara Construction and General Suppliers
m/s jogaram sujaram
M.D. CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .