SUPERINTENDING ENGINEER
SE ETC Sultanpur 400KV S/S Campus Payagipur Sultanpur
DISMANTLING OF EXISTING DEFECTIVE 05x11.50 TON AC PLANT INDOOR AND OUTDOOR UNIT AND PROVIDING, INSTALLATION OF 05X11.50 TON AC PLANT INDOOR AND OUTDOOR UNIT WITH ALL ASSOCIATED WORK AT 400KV S/S SULTANPUR UNDER 400 KV SUBSTATION DIVISION SULTANPUR
2024_UPTCL_927544_1
V.S.T. T.No. 10/ETCS/2024-25
Open Tender
Electrical Works
Item Rate
30 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE ETC SULTANPUR
₹14,000
29 Jun 2024
11 Jun 2024
24 Jun 2024
11 Jun 2024
24 Jun 2024
11 Jun 2024
Amount
SUPPLY OF MATERIAL
Supply of Air cooled ceiling mounted ductable packaged air conditioner unit with scroll compressor complete with indoor units, outdoor condensing untis, all control charge of oil and gas etc. Hitachi or similar Make, Capacity 11.50 TON each.
Supply of acoustic duct with 12mm thick rigid board covered with fiber glass (Crown 300) RP tissue paper & aluminum foil etc as required.
Supply of duct insulation with 25mm thick resin bonded UP TWIGA fiber glass (Crown 150) covered with fire proof fiber glass aluminum faced or similer.
Supply of refrigerant pipe & insulation as required.
WORK OF INSTALLATION
Dismantling of existing defective AC Plant indoor and outdoor unit of 11.50 TON Capacity and stacking the dismaintled plant & machinary at loaction directed by the engineer.
Installation, testing and commissioning of air cooled ceiling mounted ductable packaged Air Conditioner unit with scroll/recipe compressor complete with indoor units, outdoor condensing units, all contol charge of oil and gas etc. Hitachi or similar Make, Capacity 11.5 Ton each.
Dimantling the existing defective duct, carrying necessary repair at rusted duct and fixing the repaired duct including cost of man, T&P as required for the job.
Removal of existing damaged insulation, cleaning and installation of acoustic duct with 12mm thick fiber glass (Crown 300) rigid board covered with RP tissue paper including cost of man or similar T&P as required for the job.
Removal of existing damaged insulation, cleaning and installation of duct insulation with 25mm thick resin bonded UP TWIGA fiber glass (Crown 150) covered with fire proof fiber aluminum faced of similar including cost of man, T&P as required for the job.
Dismantling of defective refrigerent pipe and Installation of refrigerent pipe including insulation for each AC system including cost of man, T&P as required for the job
M/S SAHARA TRADERS
HARE KRISHNA ENERGY PROJECTS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .