Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99 LAccepted-AOC NIZARABAN PATH HOUSE NO 36 CITY TOWN GUWAHATI P O FATASIL AMBARI P S FATASIL AMBARI DIST KAMRUP METRO PIN 781025 | KAMRUP METRO | ASSAM | 781025 | L1 | Accepted-AOC Qualified | |
| 2 | L2₹1.0 Cr+₹5.0 L (5.04%)Rejected-AOC | L2 | Rejected-AOC Qualified |
Tender Value
₹99.0 L
EMD Value
₹2.0 L
Closing Date
25 Jan 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE,KRC
O/o Superintending Engineer PWD(R),Kamrup Road Circle,Ghy-01
Reconstruction of damaged portion of Commerce College road at Boripara under state priority under SOPD-G for the year 2022-23
2023_PWD_28846_1
No.GRC/NIT/510./ 2021-22/Pt.I/72 Dtd.11.01.2023
Open Tender
Civil Works – Roads
Item Rate
Jalukbari
Please refer tender
5 documents required · 5 mandatory
₹2,971
Yes
₹2.0 L
Yes
16 May 2023
17 Jan 2023
25 Jan 2023
17 Jan 2023
25 Jan 2023
17 Jan 2023
17 Jan 2023 - 25 Jan 2023
Amount
Road Works
Dismantling Stone Masonry as per Technical Specification Clause 202 Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. (b) Rubble Stone Masonry in Cement Mortar
Removal of unserviceable soil including excavation, loading and disposal upto 1000 m lead but excluding replacement by suitable soil, which shall be paid separately as per Clause 305
Digging and de-silting of road side drain/ cross drains etc. by mechanical means with adequate road safety measures by providing caution boards/ safety ribbons/ proper barricading where necessary/ Boat for safety measure/ proper lighting if necessary etc. without damaging the slabs of port/ road surfaces etc including immediate disposal of the semi liquid/ silt/ garbage/ floating materials/ polythin etc taken out from the river, drains/ culverts etc. upto a lead of 20 Km from the site within 24 hrs as directed keeping the road surface/ footpath etc. clean and as directed by the department
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork D. PCC Grade M30 a. Height upto 5m Case I: Using concrete Mixer
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and uidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Traffic Signs A. Retro-reflectorised Traffic Signs I. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 ii. 600 mm equilateral triangle
Traffic Signs A. Retro-reflectorised Traffic Signs I. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 iii. 600 mm circular
Traffic Signs A. Retro-reflectorised Traffic Signs I. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 v. 600 mm x 450mm rectangular
Direction and Place Identification signs upto 0.9 sqm size board A. Retro-reflectorised Traffic Signs (I) Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
RCC Footpath slab with RCC Beam
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and otherstructure comprising of masonry, cement concrete, wood work, steel work,including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause303.5.2 as per Technical Specification Clause 302.3.11
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork E. RCC Grade M20 a. Height upto 5m Case I: Using concrete Mixer
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
RCC Load Bearing Drain
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I Ordinary soil A Manual Means (I) Without dewatering (i) upto 3 m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A. With crushed Stone II. P.C.C grade M 15 Nominal mix 1:2.5:5 (Hand mixing)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork E. RCC Grade M20 a. Height upto 5m Case I: Using concrete Mixer
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. Sandy material.
RCC Load Bearing slab with RCC Beam
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. (I) By manual means (b) Cement Concrete
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause303.5.2 as per Technical Specification Clause 302.3.11
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork E. RCC Grade M20 a. Height upto 5m Case I: Using concrete Mixer
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
NIPUN CHANDRA BORA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .