Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.7 L+₹1.9 L (8.99%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Being L2 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
25 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Navy Lakshadweep
GE (Navy)Lakshadweep C/o NOIC (LAM) Navy Office Coast Guard Road Kavaratti Islands UT of Lakshadweep-682555
PROVISION OF BICYCLE SHED INFRONT OF JUNIOR SAILOR ACCM, TWO NOS OF WATER COOLER IN ADMIN BLD, ELECTRIC CHIMNEY AT SHIPS GALLERY, POWER SUPPLY STABILIZER FOR NCN CENTRE, ELECTRIC SIRENS AT BASE DEPOT KAVARATTI AND MINICOY UNDER GE NAVY LAKSHADWEEP
2023_MES_624476_1
8365/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Navy Lakshadweep
As per Tender document
6 documents required · 6 mandatory
₹500
Garrison Engineer Navy Lakshadweep
₹38,000
Yes
10 Jan 2024
21 Oct 2023
29 Nov 2023
21 Oct 2023
25 Nov 2023
6 Nov 2023
21 Oct 2023 - 28 Oct 2023
Amount
Surface excavtion n exc 30 cm deep and averaging 15 cm deep and getting out hard/ dense soil complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Excavating in post holes (or similar holes) each in soft and loose soil n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC 1:3:6 Type C2 (40 mm graded aggregate) any thickness ,size of shape including in foundations, filling and mass concrete, pillasters, buttresses, columns, pillars, boundary pillars and posts (including caps and bases ) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Steel work in Roof trusses Fe 410 -W (Gde- E- 250) quality- A (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and as directed by Engineer-in-Charge.
Supply and fix for M.S Flat iron for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed by Engineer-in-Charge.
Material and Labour cement concrete type D-2, (1:4:8) using 40mm graded agregates, 100 mm thick as in sub base concrete, complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 100 mm thick, PCC (1:2:4) type B1 ,20mm graded stone aggregate as in top wearing layer, surface finished even and fair complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including necessary preparation etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces n. exc 10 cm width or girth including necessary preparation etc complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 150 ltrs and nominal cooling 150 Ltr/Hr capacity with BEE 5 star rating and CFC free refrigent complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/Usha/Blue star
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and a capacity of 5 KVA complete all as specified and as directed by Engineer-in-Charge. Make : V-Gaurd/Microtek/Everest
Material and labour Submain wiring with two runs of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC rigid non metalic conduit and one run of 2.5 sqmm size multi stranded copper conductor cable PVC insulated and unsheathed for continous earth wire including cutting chases and making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 20 Amps complete all as specified and as directed by Engineer-in-Charge.
Material and labour for elecric chimney of size 1500x600x450 mm, wall mounted hood 3.04 Grade 24 gauge Hood fabrication without filter complete all as specified and as directed by Engineer-in-Charge. Make : Glen Electric/ Hinware/Faber or Equivalent as approved by GE.
Supply and fix oil filter and oil cap inculded complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Exhaust Duct work 8x4 GI sheet 0.6 mmm guage inculding 300x300x600 mm length 01 no, 300x300 elbow 01 no, wiremesh instalation 01 no, 300x300x600 mm length fan box 01 no, supporting meterials complete all as specified and as directed by Engineer-in-Charge. Make : Tata / JSW or Equivalent as approved by GE.
Supply and fix modular switch, 1 way. 16A, 1 module complete all as specified and as directed by Engineer-in-Charge.
Material and labour for submain wiring complete with inculding 2 runs of 4 sqmm single core FRLS PVC insulated and unsheathed multistranded copper conductor cable single core 1100 Volts grade drawn through and inculding PVC conduit concealed inculding cutting chases on wall/floor etc. making good the disturbed surfaces of wall complete all as directed with accessories and 4 sqmm FRLS PVC multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. Note : Two runs 4 sqmm PVC insulated cable and one run of 4 sqmm cable and one run of PVC conduit shall be
Material and labour for point wiring with copper conductor cable FRLS one light point or one fan point controlled by one switch with 2.5 sqm size in PVC concealed conduit complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300 mmcomplete all as specified and as directed by Engineer-in-Charge.
Supply and fix double door, sheet metal enclosure powder coated MCB DB SPN 8 way with 200 Amps rated bus bar, 240 volt, horizontal type, IP 43 protection, flush in walls inculding making good of disturbed surface to match with existing surface complete all as specified and as directed by Engineer-in-Charge. Note: Blank spaces of DB shall be covererd with blank plate.
Supply and fix MCB SPN 32 amps, 240 volts, 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB SP 5 amps to 32 amps, 240 volts, 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and installation testing and commisioning of oil cooled servo control voltage stablizer with 425 litre oil, indoor type for automatic operation three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output volatage stabilized at 415 with accuract + 2.5 % and speed of correction 8 volts per second and of capacity 150 KVA complete all as specified and as directed by Engineer-in-Charge. Make: Electro power control or Equivalent as approved by GE.
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth leas 32x6 mm size, by means nut, bolt, check nuts and washer of Galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40 mm bore incl provn of concrete pit on PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 ltr all as per electrical plate No.3 of SSR Part I and connecting to earth test point all as specified including testing complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting soft/loose soil for laying of cables/pipes/erection of poles etc. complete all as specified and as directed by Engineer-in-Charge.
Returning filling in, with excavated soil inculding spreading, leveling, watering and well ramming in layers not exceeding 25cms complete all as specified and as directed by Engineer-in-Charge.
Removing excavated materials /surplus soil exceeding 250m and n. Exc.500m and deposting where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sand cushioning with Sand in two layer, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable inculding consolidation of each layer complete all as specified and as directed by Engineer-in-Charge. Note : Thickness of sand cusioning shall be measured after punning.
Supply and laying unreinforced precast concrete cable cover class LV 1 flat size of size 250x150x40mm for LTC Cable all sizes complete all as specified and as directed by Engineer-in-Charge.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm 31/2 core complete all as specified and as directed by Engineer-in-Charge.
Material and labour cutting the exisiting road for laying of cables and pipes in hard standing of size and pavings n.exc 15 cms thickness (below ground level0 for road cutting channel to lay pipes complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 80mm dia GI Pipe (ISI Marked) medium grade for cable protection in road crossing as ordered of complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing, testing commissioning eletrically operated flame proof sirens (Group IIA & IIB) horizontal double mounting siren three phaes 400/440V, 2800 rpm, 50 Hz, AC, 2 HP capacity, 3.25 Km range at ND Minicoy complete all as specified and as directed by Engineer-in-Charge. Make : Kheraj Electrical industries Pvt Ltd, Model : FD - 325 or Equivalent as approved by GE.
Supply and fixing, tesing, commissioning electrically operated flame proof sirens (Group IIA & IIB) horizontal double mounting siren three phases 400/440V 2800 rpm, 50 Hz, AC, 01 HP capacity, 1.5 KM rangef at INS Dweeprakshak complete all as specified and as directed by Engineer-in-Charge. Make : Kheraj Electrical industries Pvt Ltd Model : FD-150 or Equivalent as approved by GE.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 sqmm 4 core complete all as specified and as directed by Engineer-in-Charge.
Supply and fix tubing 50 mm dia light grade ISI market laid in trenches complete with all accessories such a tees union, bend elbow nipple reducer etc etc as reruired for protection of UG Cable in floor, Pole etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cutting the existing hardstanding not less than 25 cm in deep and 45 cm in width for laying of underground cable through GI pipe and making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Jack Electrolinks Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .