Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-Finance 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-Finance Accepted being L1 | |
| 2 | L2₹46.4 L+₹39,662.21 (0.86%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.4 L+₹2.4 L (5.22%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.0 L+₹3.0 L (6.54%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.1 L+₹3.1 L (6.85%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
13 Mar 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
RENOVATION OF P 10 LPDC HANGAR INCLUDING PROVISION OF OBSERVATION CHAMBER WITH MAZZANINE FLOOR REPLACEMENT OF VALLEY GUTTERS ROOF SHEETING FLOORING WITH EPOXY ETC AND OTHER CONNECTED E M WORKS AT ADE AND CERTAIN MINOR WORKS IN CABS CEMILAC AND ADA U
2020_MES_323089_1
8906
Open Tender
Civil Works
Item Rate
270 days
GE RD East Bangalore
D a (i) b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹85,000
Yes
16 Mar 2020
8 Feb 2020
16 Mar 2020
8 Feb 2020
13 Mar 2020
1 Mar 2020
10 Feb 2020 - 24 Feb 2020
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) and removal of debries to a distance not exceeding 100 metre complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in sub base etc complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in floors/paving finishing the surface even and smooth without using extra cement concrete complete all as specified and directed.
Material and Labour for 2mm thick epoxy resin based floor topping after priming the surface solvent base epoxy resin primer designed for maximum absorption and adhesion as per manufacture specification including preparation of floor by wire brushing or light grit blasting to remove laitance, dust and cleaning the same to achieve mechanical key between the floor and coating system and applying epoxy putty mixed with suitable fillers to cover the worn out areas all as specified and directed. Note :- (a) Floor topping shall be Nitoflor SL 2000 of M/s FOSROC/MASTERTOP TM 1215 PLUS of BASF or equivalent in CIPY. (b) Primer shall be Nitoprime 25 of M/s FOSROC or equivalent in BASF/CIPY. (c) Epoxy putty shall be Nitoflor FC 140/150 of M/s FOSROC or equivalent in BASF/CIPY.
Dismantling structural steel work including doors, gates, stairways but excluding framed truss etc.
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0
Ditto but fabrication and fixing only after made it shaped with old steel obtained from dismatling existing bracings etc.,
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, valley gutters etc.,
Supply & fix in repairs (including dismantling) GI plain , galvanised mild steel sheeting, 1.25mm thick, in ridges. as in valley gutters with grade of zinc coating 275 of fixed with made up FI clamps with running welding joins (no reviting allowed between sheet to sheet joint while fabricating valley gutter to achieve length required at site) complete all as directed. Note : (a) Approximate height of the work is up to 12 Mtr (b) There is no accessibility to the roof therefore scaffolding of H frame should be provided to work force whithout any extra cost to the govt.(c) Necessary scaffolding if necessary to fix valley gutter.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Running welding in repairs thickness of metal to be welded exceeding 6mm but not exceeding 9 mm
Taking down AC, PVC air, vent, soil and rain water pipes of dia, 110mm fixed to wall or in trenches etc,.
S & F UPVC (SCH-40) pipes 150 mm bore fixed as in vertical stacks including joints/fittings fixed to walls. Note : "Making proper leak proof joint with valley gutter to the newly fixing pipe with funnel type made up galvalum sheet material as same as valley gutter, the same will be measured under item 2 above complete"
S & F UPVC 150 mm bore bends of any radius complete all as specified
M & L anodised aluminium snap grid frame work for false ceiling all as specified
M & L in 12 mm thick prelaminatd particle board as in ceiling board of 600 x 600 mm sizes, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
M & L in repairs including taking down of existing ceiling and providing 12 mm th prelaminatd particle board as in ceiling board of 600 x 600 mm sizes, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including anodised aluminium snap grid frame work for false ceiling all as specified
Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
Taking down cement or cement lime plaster of any description from walls, including racking out joints hacking for key scrubbing down with water etc , complete all as specified.
M&L 15 mm thick external plaster in CM 1:4 on fair faces of walls , finishing the surfaces even and smooth w/o using extra cement complete all as specified and as directed
M&L for preparing new plastered surfaces of wall and including two coat of exterior plastic emulsion paint over a coat of primer complete all as specified and directed
Material and labour for preparation of old wall surfaces by complete removal of existing treatment, preparing wall surfaces and applying one coat of exterior plastic ( weather coat) emulsion paint like Apex in asian paint or its equivalent complete all as specified and as directed
M&L 10 mm thick internal plaster in CM 1:6 on other than fair faces of walls , finishing the surfaces even and smooth w/o using extra cement complete all as specified and as directed
M & L for preparation of new plastered or unplastered of un decorated surface of walls, chajja, balcony, facia etc by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss, efflorescent salts, treading oil and greasy spots, and applying two coat of interior dust proof plastic emulsion paint over and including a coat of priming paint over 2 mm wall care putty including sand papering to obtain smooth finish complete all as specified and directed. Make : Royal in Asian or its equivalent in berger/Johnson/Nicholson.
Ditto but on old surfaces after and including complete removal of existing treatment of any type and condition complete all as directed by EIC
M & L two coat of synthetic enamel paint over old painted steel surfaces, over 10cm in width or girth, not otherwise described incl preparation of new or old previously un treated surfaces.
M&L Preparation of new steel and iron based surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
M&L Vitrified ceramic tiles of size 10 mm thick dark shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed
Taking down chowkhats or frame n.exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame) complete all as specified.
Taking down frame/partition walls of any description exceeding 1.5 but not exceeding 4 Sqm each with shutter/panel complete all as specified.
Refixing shutter, in the same opening, of any description area exc.1 but not exc 2 sqm complete all as specified and directed.
S&F powder coated aluminium frame and/or shutter for doors and windows of any section and type, ventilators, partition/work station cubicles etc., with one or more rebates including joining cleat, rubber beading for fixing, star or suitable lock etc complete all as specified and directed.
Supply and fix for heat absorbing glass of 3 mm thick of any size complete all as specified
S&F 9 mm th Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified
S & F Aluminium anodised barrel tower bolts 150 mm length of extruded section
S & F Butt hinges,100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete
S & F Aluminium handles, cast type anodised oval or 'D' type of size 100mm complete
S&F venetian blinds, vertical type, 100 mm slot width of approved fabric and powder coated aluminium top railsetc complete all as specified, including dismantlilng old damaged one complete all as specified and as directed. Note:The colour,design and shade shall be as approved by GE.
M&L Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed
M&L Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed
S&F Mild steel bolts size of neck size exc 20mm but n.exc 25 mm, purpose made, with hexagonal or square head one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long complete all as specified and as directed
S&F brass mortice lock, vertical type, size 100 mm , 4 levers, complete all as specified
S&F Aluminium body door closer hydraulically regulated designation No 2, universal type suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete complete all as specified and as directed
S&F floor door stopper of aluminium body and toungue, anodized with hard drawn steel spring 150mm complete.
S & F Aluminium alloy anodised Sliding bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles.
Material and labour for brick work with sub class 'B' straight or curved on plan exc 6 m radius with old size bricks built in CM 1:4 complete all as specified and as directed
Supply and fixing poly carbonate coloured sheets 6mm thick as in roofs with adequate size steel screws , washers, nuts, tie band as approved, etc as per manufacturer’s instructions, fixed as in repairs by removing glass with frame as in northlight glass etc., complete all as specified and directed. Make of sheet shall be GE POLYCARBONATE/TUFF LIGHT.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface
M&L PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc, complete all as specified.
M&L for RCC type B1, 1:2:4 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed
S&F Hard drawn steel wire fabric 50 x 50 mm square and 5 mm dia wire, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete
M & L 40mm thick Plain cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) complete all as specified and as directed
M&L Vitrified ceramic tiles of size 10 mm thick light shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete
S&F Anodised aluminium frame powder coated for doors , windows, ventilators and partition with one or more rebates including joining cleat,rubber beading for fixing, star lock etc complete.
Anodised aluminium anodised door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door,aluminum hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F sheet glass 5.50mm thick ordinary quality frosted on one side in exc 0.5 sqm in each pane with rubber beading as in doors and partion with rubber beadings suitable for aluminium frame work complete all as specified and as directed
S&F 12 mm thick pre laminated particle boards exterior grade, prelaminated both sides with decorative chocie laminations fixed in aluminium partions/doors with rubber beadings or fixed with screws to timber frame works complete all as specified and as directed.
S & F Mild steel work such as window grills and angle iron for doors, grills or gate of angle of other section gusset plate rails ladder & Hand rail including welding securing bolts including cutting tops to shape as directed, drilling holes etc conforming to Fe 410 -O or Fe 310 - 0, complete all as specified and as directed by Engineer-in-Charge
M&L preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Material and labour for pre-cast cement concrete block masonary with solid block set in cement mortar type C1, 1:3:6 using 20mm graded aggregate, exceeding 10cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
Providing and fixing of Armstron ceiling system with fine fissured edge tiles having humidity resistance (RH) of 95%, NRC 0.34 light reflectance approx 84% Thermal conductivity K=0.052 - 0.057. W/mk colour white fire performance of class- I as per BS 476 part 6 & 7 in module size of 600 x600x16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong silhouette profile exposed grid system with 15 mm white flanges incorporating 6 mm central reveal in white/black colour. Silhoutte, main runners & cross Tees to have mitred ends & birdsmouth notches to provide mitred cruciform junctions. The Tee sections have a galvanising of 170 gms per m2 & passed through 500 hrs of salt Test. The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using Armstrong suspension system at 1200 mm maximum c/c. The first/last Armstrong suspension system at the end of each main runner should not be greater than 450 mm from adjacent wall. Cross Tees 1200 mm long should be interlocked between main runners at 600 mm c/c to form 1200 x 600 mm module. 600 x 600 mm module is fortned by fitting 600 mm long flush fitting cross Tees, Perimeter trim consist of Armstrong wall angles of size 3000 x 19 x 19 mm secured to walls screws at 450 mm c/c.
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, with non metalic rigid PVC medium duty conduit with accessories such as junction boxes, bends, tees etc. of suitable size including modular terminal box & Cover plate for mounting of switches, sockets fan regulators etc and including continuous earth wire PVC insulated 1.50 Sq mm copper stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following :-
(a) For one light point controlled by one switch
(b) For one fan point controlled by one switch through regulator
(c) For one three pin socket out let 5 amps on independent board complete.
(d) For one three pin socket point 5 amps on same board complete.
Supply and fix modular switch one way 6 Amps, 1 mole
Supply and fix socket 6 A 2/3 pin combined 2 module
All as per item No 66 here in before, but with cable 4.0 sqmm (nominal area) multi stranded copper wire unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor, connecting to common earth and earth dolly complete.
All as per item No 66 here in before, but with cable 2.50 sqmm (nominal area) multi stranded copper wire unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor, connecting to common earth and earth dolly complete.
Supply and fixing of Modular switch piano 6 A,230 Volts
Supply and fixing of Modular switch piano 16 A,230 Volts
Supply and fixing of Modular fan regulator step type 100 w,230 Volts
Supply and fixing of Modular socket piano 6 A,230 Volts
Supply and fixing of Modular socket piano 16 A,230 Volts
Supply and fixing of socket 6A/16A 2/3 pin combined, 2 module, modular type
Supply and fixing ceiling rose surface type 3 terminals 65x20mm compelete all as specified
M & L for sub main wiring with four single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4 x 10.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit, 4 runs of cable and 2 run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2 x 6.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 6.00 sqmm cable and one run of 4.00 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2 x 4.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 4.00 sqmm cable and one run of 2.50 sqmm of earth wire shall be measured and paid as one unit.
S & Replacement of Distribution Board, TPN 8 way, 240V, double door type.
Supply and fixing of MCB, SP, 240V, upto 40 Amps 10KA rupturing capacity.
Supply and fixing of MCB, SPN, 240V, upto 40 Amps 10KA rupturing capacity.
Supply and fixing of MCB, TPN, 415 V, upto 63 Amps 10KA rupturing capacity.
Supply and fixing of Energy efficient (5 Star rated) ceiling fan 1200 mm sweep single phase 230 / 240 volts AC with necessary fitting and connceting with cable from ceiling rose or connector to fan including taking down carefully old ceiling fan with necessary fitting and making good to damaged surface of wall/ceiling to match existing finish all as specified and directed.Make : Cat No : SS-390 of Havells or Equvalent.
Supply and fixing of wall mounted fan, type 400 mm sweep, AC, 1400 RPM single phase 230/240 Volts complete accessories including connecting with suitable size of copper flexible wire complete all as directed. Make : Havells, model : SWING or Equvalent in CG/BAJAJ/PHILIPS
M & L for earthing complete with copper earth plate of size 600 x 600 x 3.15 mm buried directly and preferably vertically in ground with top edge not less than 1.25M below ground level connected with copper earth strip of 20 x 3 mm connected to the earthing test point all as specified and all as directed by Engineer incharge including testing and submission of test reports. Note : The rates quoted are inclusive of copper earth strip upto the standard length as specified in the SSR part -1. However additional length will be measured and paid seperately in respective item.
M & L for copper earth continuity main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 25 x 3 mm all as specified and directed.
Supply and fixing DLP U-PVC Cable trunking systems and acessories snap on trunking 80 x 50 mm supplied without cover, Legrand Cat no : 010412 80mmx50mm PVC Trunking
Supply and fixing of Flexible cover only, full cover size width 65 mm suitable for 80mmx50mm PVC Trunking Make : Legrand Cat no. : 010521
Supply and fixing of LED tube light fitting Recessed/surface 2 x 2 type fitting complete all as directed. Make : CG , model : POLARIS III, CAT REF : LCTLSN-36-CDL or Equvalent in CG/BAJAJ/PHILIPS
Supply and fixing of MCCB of capacity 125 Amp,415V,25 KA,TPN,
Supply and fix exhaust fan, heavy duty with metalic body 300 mm sweep complete with louvre shutter, 230 / 240 V, 1400 RPM including connection and provision of flexible copper wire from ceiling rose to fan complete all as specified and as directed. Make: Havells, Model: Turbo Force SP or equivalent in Bajaj / Usha
Making hole in wall masonry/cutting of window glass for fixing of exhaust fan of size 300mm size and finishing work as per existing and match with surrounding surfaces complete all as specified and as directed
S&F DGS 1210-28 (DGS-1210) series gigabit smart managed switches
S&F IO Box 1 port plate
S&F D Link RJ 45 connector box (100 Nos)
Supply and lay D Link CAT 6 cable
Supply and laying industry casing complete
Lucky Enterprises
SENTOOR BUILDERSS
Atom Engineers and Builders
SAI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .