Loading…
Loading…
Tender Value
₹9.0 Cr
EMD Value
₹6.0 L
Closing Date
5 Mar 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate Interlocking or AFTC or SSDAC or MSDAC or HASSDAC or BPAC.
10 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure- V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
1)Intending tenderer must understand the work before quoting. The submission of tender shall be deemed to have been done after careful study and examination of the papers as well as work site and understanding of the implication thereof. 2) Quoted rates shall include all types of taxes (GST etc.), duties, carrying cost of all materials for the work including loading and unloading involved in the concerned work. 3) All supplied materials to be deposited at the office of SSE/Sig./Store/ASN for signalling materials and SSE/Tele./Store/ASN for telecom materials 4) All materials supply by the Rly. have to be transported from the office of the SSE/Sig./Store/ASN or SSE/Tele./Store/ASN to the site of work by the contractor's own arrangement. 5) Any material, which is required for execution of the work, not mentioned in the schedule as Railway supply, contractor has to arrange for the same as per advice of Rly. Site Engineer. 6) Painting to be done on all items as per provision of Signal Engineering Manual/Rly , as per Rly. site engineer. 7) Items supplied by the contractor will be inspected by authorized representative of Sr.DSTE/ASN except those materials which will be inspected by RDSO / RITES/TPI. If total value of a item is more than 5 lakhs , then inspection of that item to be done by RDSO/RITES/TPI. Inspection cost, if any, shall be applicable as per latest rules and guidelines. 8) Any required drawing may be collected/ consulted from Sr.DSTE/ASN's office.
9) A site supervisor from contractor side shall be present at site during execution of work. Execution work at site will be done as per instruction of Rly. site engineer. 10) Care should be taken to avoid damage to existing gears during the work. Any damages to the Railway property shall be made good by the contractor in his own cost. 11) The Contractor & his supervisors, staff must take proper precaution during working in Railway area to prevent any interference with existing Rly. system, working & passengers. 12) All the tools and other testing equipment for installation, testing and commissioning should be arranged by the contractor at his cost. 13) Contractor have to submit indemnity bond for safe custody and protection of railway materials during transportation ( sample may be collected from office). 14) Latest guideline of Railway Bd.'s vide letter no. 2018/CE-I/CT/9 dated 04.06.2018 regarding "Letter of Credit" as Mode of payment in Works Tenders or Service Tenders is attached in pdf file. 15) Eastern Railway JPO No.94 for protection of cables is attached in Annexure-I. . Accordingly, while working near underground Signalling, Electrical & Telecommunication cable, proper care should be taken to avoid the cable cut/damage, other wise the penalty amount as per Railway Guidelines will be recovered from the contractors. 16. PVC clause shall be applicable only in tender having advertised value above Rs.2 Crore vide Railway Bd,s letter no. 2022/CE-I/CT/GCC- 2022/Policy, dated 14.07.2022.
Asansol Division: Provision of SSBPAC (D) replacing TLBI in E Route.
38-SDSTE-ASN-2025-26
38-SDSTE-ASN-2025-26
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹6.0 L
5 Mar 2026
8 Feb 2026
145 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,96,11,377 | ||
| — | 13.00 | — | — | ||
| Supply & transportation of Solid state Block proving by Axle Counter (Digital) (SSBPAC(D)) for Single line section as per RDSO Specification No. RDSO/SPN/175/2005 Ver. 1 or latest along with station master block panel along with DTMF based Electronic Block Bell & Block Telephone equipment as per specification No. RDSO/SPN/191/2005 (Ver. 0) or latest. Each set consists of following (i) Microprocessor based station master Block Panel with Block Telephone - 2 sets, (ii) Microprocessor based SSBPAC (D) block instrument with wired Relay rack along with relays as per drawing no. RDSO/S/32023- 2 sets, (iii) Lightning & Surge protection devices (C & D class) - 2 sets, (iv) Inbuilt media changeover - 2 sets. v) EKT for Shunt Key as per Drg. no. SA-22601/Alt.4 or latest - 2 sets. System working on redundant channel for data transmission in OFC/Quad/Microwave/Radio. Inspection: RDSO. | — | — | — | 1,35,59,845 | |
| — | 13.00 | — | — | ||
| Installation, Testing and Commissioning of Solid state Block Proving by Axle Counter (Digital) (SSBPAC(D)) for single line section using Block Panel complete with all accessories as per Specification No. RDSO/SPN/175/2005, Ver 1.0 or latest. Installation, commissioning to be done by OEM or OEM authorised representative. Pre commissioning check list to be signed. This work to be done as per guideline of Eastern Railway, R.Bd., RDSO. In unit column set means pair. | — | — | — | 11,65,359 | |
| — | 26.00 | — | — | ||
| Supply of Block Telephone complete with PTT Handset suitable to working with block panel and UFSBI/Solid state BPAC as per IRS Spec No. IRS: S 105/2012 or latest & RDSO/SPN/175 /2005, Ver 1.0 or latest. Inspection: RDSO | — | — | — | 4,37,190 | |
| — | 11.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. | — | — | — | 2,96,95,809 | |
| — | 5.00 | — | — | ||
| Supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO.S&T/C-20/2001 or latest Inspection: Consignee | — | — | — | 1,27,675 | |
| — | 5.00 | — | — | ||
| Erection, Installation , wiring of relay rack as per instruction of Rly site engineer and as per Drg. No. S&T/C/20/2001(modified). This work include ssupply of fuse block with fuse, bus bar, PBT terminal /Tagblocks, resistance, diodes, condensers, PVC wire as per RDSO Spec. No. IRS- S76/89(Amd-3) or latest (for wiring/inter-wiring of relay racks, CTRs, tagblocks) hylum sheet and other scaffolding materials to be supplied by contractor as per requirement. PBT terminals, PBT fuse block, PVC wire to be procured from RDSO approved firm and to be inspected by RDSO. This work includes fixing of relays with base , interconnection wiring with ladder arrangement of relay rack and complete wiring of relays by soldering/termination of wire at relay base as per wiring diagram and fixing of fuse block, diodes, resistance, condensers, terminal blocks, bus bars and other equipments required for the approved system design complete with supply of erection materials. This also includes laying , dressing of cables, wires for relay rack, CTR, panel, IPS/power equipment with supply of thread, wire guide, ladder guide , masonary materials and reinstatement of floor, wall as per requirement. This includes status of relay to be indicated through LED indication on top of rack, lettering of each relay on rack strip and lettering/numbering of terminals, fuse for circuit used in brief. Rack to be fixed on rubber pad. Ladder arrangement to be done from relay rack, panel, IPS/power equipment as per requirement. Ladders and its accessories for this work to be supplied & fixed by contractor. | — | — | — | 4,15,160 | |
| — | 100.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABCDF". Inspection:- RDSO | — | — | — | 3,73,700 | |
| — | 250.00 | — | — | ||
| Carrying out relay alteration / relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and to be inspected by RDSO. All required materials like wire, soldering materials, paint etc. to be supplied by the contractor for execution of the work. | — | — | — | 67,500 | |
| — | 2000.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wirefront entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004. The colour will be decided by Engineer - in Charge. (Preferably In Blue, Red &Grey Colors in the ratio of 1:2:3).Inspection: RDSO . | — | — | — | 1,10,000 | |
| — | 200.00 | — | — | ||
| Supply of End plate 2.5mm/0.091in thick in connection with above disconnect type terminals. Inspection: consignee | — | — | — | 2,000 | |
| — | 100.00 | — | — | ||
| Supply of End Stopper10mm/0.0394 in connection with above disconnect type terminals .Inspection: consignee | — | — | — | 1,000 | |
| — | 200.00 | — | — | ||
| Supply of shorting link ( jumper) suitable for 0.2 to 16 sq mm terminal block. Inspection: consignee | — | — | — | 400 | |
| — | 50.00 | — | — | ||
| Supply of steel Carrier Rails for placing disconnect type terminal of size 35mm x 7.5mm, 1mm/0.039in thickness un-slotted type for placing disconnect type terminals. .Inspection: Consignee | — | — | — | 5,450 | |
| — | 250.00 | — | — | ||
| Supply of fuse, non-deteriorating (2A/6A/10A/16A) type, cylindrical (IRS-S-78/92) [quantity against different amp. rating as per Rly. Engineer will be fixed during supply]. Inspection: RDSO | — | — | — | 15,250 | |
| — | 50.00 | — | — | ||
| — | — | — | 8,900 | ||
| — | : - Supply orlatest,DRG.NO.SA23748.Inspection: | of fuse -RDSO. | — | ||
| — | — | — | tospec.no.IRS-S-75/2006(REV-2) | ||
| — | 30.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 1,61,100 | |
| — | 14.00 | — | — | ||
| Modification, alteration of existing datalogger to suit the alteration work as per advice of Rly. Site engineer. This work includes validation, changes of NMDL software, wiring etc..For this work necessary wire from relay to tagblock & from tagblock to data logger, tagblock, terminal , soldering material etc. to be supplied by contractor. Wire to be procured from RDSO approved firm and to be inspected by RDSO. This modification to be done by engineer/representative of OEM of data logger. | — | — | — | 6,88,240 | |
| — | 26.00 | — | — | ||
| Releasing of existing Block Instrument and allied gadgets, wiring etc. as per instruction of Rly. Site Engineer | — | — | — | 20,332 | |
| — | 105.00 | — | — | ||
| Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll for each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: RITES | — | — | — | 66,01,035 | |
| — | 105.00 | — | — | ||
| Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of mono-mode armored OFC cable (48 fibers) through duct in trenches and as advised by site engineer. Note: - (1) the contractor will take over the OFC cable from railway store to site of work duly checked the continuity of each fiber from end to end. (2) before & after laying of optical fiber cable through duct, continuity test from end to end of each fiber to be made by the contractor to ensure availability of all 24 fiber duly certified by the site engineer. | — | — | — | 25,97,070 | |
| — | 40.00 | — | — | ||
| Supply of 48 Fiber OFC Joint Closure similar to Specification No. RDSO/SPN/TC/68/2014 Rev 1.0 or latest including sealing with mechanical clamps. Inspection: Consignee | — | — | — | 90,560 | |
| — | 40.00 | — | — | ||
| Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | — | — | — | 2,66,960 | |
| — | 800.00 | — | — | ||
| Laying, Fixing, installation of GI pipe with threaded collar of 100 mm nominal bore perforated of required length on bridge, below road/LXing/ track, on wall or at other site and laying of signalling cable/rod through it with supply of necessary materials as required for execution of this work. The work to be done as per instruction of Rly. site engineer. | — | — | — | 78,400 | |
| — | 30.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 1,07,880 | |
| — | 500.00 | — | — | ||
| Supply of UTP CAT-6 cable make Siemen/ Systemax /Panduit/ Tyco/ Krone/ AMP. Inspection: Consignee | — | — | — | 9,500 | |
| — | 500.00 | — | — | ||
| "Laying of UTP/STP CAT-6 cable/power cable in PVC casing capping of appropriate size. The work also includes supply and fixing of casing and capping, fixing and connection of patch panel, fixing of CAT-6 cable with RJ 45 connectors. Work to be done as per instructions of site in- charge. | — | — | — | 22,500 | |
| — | 1400.00 | — | — | ||
| Supply of 50 mm (outer dia) PVC conduit pipe circular rigid plain medium class socket ended as per specification no. IS:9537 (part-1 & part-3) with latest amendment having ISI marked & one socket at every 3 meter pipe length. Inspection : consignee. | — | — | — | 1,07,800 | |
| — | 1400.00 | — | — | ||
| Laying, Execution/fixing of PVC conduit pipe of 50 mm dia on wall/Shed including supply of all fixing materials & accessories by contractor. | — | — | — | 28,000 | |
| — | 14.00 | — | — | ||
| Inter connection wiring with ladder arrangement from SSBPAC/control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re-arrangement of DC-DC converters by OEM of IPS | — | — | — | 9,77,536 | |
| — | 3.00 | — | — | ||
| Supply of PVC insulated Railway Signalling multicore Indoor Cable 60 core (0.6mm dia) conforming to IRS:76/89(Amd3) or latest. Inspection: RDSO | — | — | — | 4,53,096 | |
| — | 14.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO | — | — | — | 2,12,058 | |
| — | 14.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467- 2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee | — | — | — | 92,106 | |
| — | 14.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right-hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | — | — | 1,80,404 | |
| — | 56.00 | — | — | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | — | — | 1,62,512 | |
| — | 14.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee | — | — | — | 2,40,282 | |
| — | 12.00 | — | — | ||
| Supply of Digital Multimeter of Fluke 287 Industrial or Similar/ superior True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 5,28,768 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument_SnT.pdf
GCC_April-2022.pdf
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
mergedGCCCorrectionslip3456.pdf
2018-CE-I-CT-9dtd.pdf
Annexure-C.pdf
AllAnnexure.pdf
CheckList.pdf
Modified_Cable_cut_JPO_NO._94.pdf
MergedGCCCorrectionSlip78910.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .