Loading…
Loading…
Tender ID
Tender Value
₹14.6 Cr
EMD Value
₹24.6 L
Closing Date
8 Apr 2026, 3:00 pmClosed
SHRAWAN KUMAR VYASH
EE
E.E. L.A.E.O. WORKS DIVISION-JEHANANBAD
ARBIND BHARTI
CHIEF ENGINEER
CONSTRUCTION OF YOJNA BHAWAN IN JEHANABAD DISTRICT HEADQUARTER
128522
NIT-05/SBD/2025-26/LAEO/W.D.-JEHANABAD/GR NO-1
Open Tender
CIVIL
Jehanabad
• NAME OF BIDDER WITH ADDRESS
CIVIL
PERCENTAGE
L1
1
20 documents required · 20 mandatory
₹10,000
Processing Fee: 5900
₹24.6 L
C.E. OFFICE L.A.E.O. PATNA
2 Apr 2026
2 Apr 2026
9 Apr 2026
2 Apr 2026
8 Apr 2026
2 Apr 2026
3 Apr 2026
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . Including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Excavating, supplyingand fillingof local earth (including royaltybut excludingcairriagecost) bymechanical transport uptoa leadof 3km also including ramming and watering of the earth in layers not exceeding20cmintrenches,plinth,sidesof foundationetc.complete. If localearthisavailableatmorethan3kmleadtheactual leadmust beapprovedbycompitentauthority. cairraiageofmaterialwillbepaid seperately and calculated after deducting initial lead.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Extra for additional lift 1.5
supplying and filling in plinth with local sand and under floors including, watering ramming consolidating and dressing complete.
providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per specification and direction of E/I
Providing Centering and Shuttering including strutting, propping etc and removal of form for: foundations,footings,bases column
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4 (1 Cement; 2 coarse sand :4 graded stone aggregate 40 mm nominal size)
Providing Centering and Shuttering including strutting, propping etc and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position machine batched, machine mixed and nmachine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-25 grde reinforcd cement concrete All works above plinth level upto floor V level
Providing Centering and Shuttering including strutting, propping etc and removal of form for: G.beam Lintels, beams, plinth bams, griders, bressumers and contilevers.
Providing 100A Brick work in cm 1:6 in foundation and plinth etc. all complite job.
Providing fly Ash brick works (1:6) in in Fdn. And Plinth
Providing and laying in position specified grade of reinforced cement concrete M25 Mix in Foundation and Plinth excluding the cost of centring ,shuttering, finishing an reinforcement -
Providing Centering and Shuttering including strutting, propping etc and removal of form for: Chhajja
Providing Centering and Shuttering including strutting, propping etc and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick.
Providing Centering and Shuttering including strutting, propping etc and removal of form for:Edges of slabs and breaks in floors and walis-
Walls Of Any Thikness
TMT Bar: 8mm Dia
TMT Bar: 10 mm Dia
TMT Bar: 12 mm Dia
TMT Bar: 16 mm Dia
TMT Bar: 20 mm Dia/25 mm Dia
Providing fly Ash brick works (1:6) in super structure.
Providing fly Ash brick work in125 mm thick in CM(1:4) in super structure.
Extra for providing and placing in position 2Nos, 6mmdia,MSbars at every third course of half brick masonry (with F. P. S. bricks)
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard designcomplete.
12 mm cement plaster of mix:1:6(1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.1:6(1 cement: 4 coarse sand )
Neat cement punning over plaster surface etc.
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
6 mm cement plaster to ceiling of mix :1:4(1 cement: 4 coarse sand)
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with floating coat of near cement
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Red sand stone-exposed face fine dressed with rough backing 40 MM Thick
Extra For plastering walls of height more than 10 M from ground level for every add it rate height of 3 ….....etc. all complete job.
Providing and applying white cement based Putty of avg. 2mm thick
Distempering with Oil bound washable distemper…do..do etc.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming coat of exterior primer
Providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i)1st courseof applyingcement [email protected]/sqmmixedwithwater proofing compound conforming tc IS 2645 in recommended proportions. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii)3rdcourseofapplyingblownor/residualbitumenapliedhotat1.7kg. per sqm of area, (iv)4thcourseof400micronthickPVCsheet.(Overlapsat jointsofPVC [email protected] kg/sqni)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Providing and fixing Marble Stone flooring with 18mm thickGranite of any colour and shade
Extra for Nosing in Granite for tread…do…do etc.
Glazed Vitrified Wall tiles Matt/ Antiskid finish of size Size of Tile 600 x 1200 mm
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08% and conforming to IS : 15622of approved make in all colour sand shades, laid on 20 mm thick cement mortar 1:4 (1cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete Size of Tile 50x50 cm.
Providing and Laying Vitrfied floor tiles…do..do etc
Providing and Laying Skirting Vitrfied tiles…do..do etc
Chequered terrazo tiles 22 mm thick with marble chips of sozes upto 6 mm in floors jointed with neat cement slurry mixed with pigement to match the shade of the tiles, including rubbing and polshing complete on 20 nm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) Light shade using white cement
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
Design/supply/installation of Exterion signage to Be fixed with the Help of Aluminium pipe Framework and Cladded with 3mm ACP(As per site Requirement IfNeeded)and Letters to Be made of stainless steel of 304 Grade Raised by 25mm From the Base The Scope Includes Completion of Job in All Respects Including Hardware in All HINDI/ENGLISH & URDU Language Letter Size 15"
Design/supply/installation Building/ Directory Signage With Acrylic Base of Thickness 5mm
Providing and Fixing of Aluminium Signages Modular FLAT Frame Technology Of Various Widths and Lengths To From Suggesterd Usages Made Of Aluminium Extruded Sections Duly Anodised All Signages Shall Be providing With 0.6-0 8MM Prolycarbonate Protelcting Film Over the Pnnta of Appropriate Size Print Shall on 0.6mm Coated YUPO Make Biogradable Flat Bed Printed Overall Size 150mm X 300mm Sheet Printer on HP4500 UV Flat Bed Printed Overall Size :- 150mm X300MM
Providing and Fixing of Aluminium Signages Modular FLAT Frame Technology Of Various Widths and Lengths To From Suggesterd Usages Made Of Aluminium Extruded Sections Duly Anodised All Signages Shall Be providing With 0.6-0 8MM Prolycarbonate Protelcting Film Over the Pnnta of Appropriate Size Print Shall on 0.6mm Coated YUPO Make Biogradable Flat Bed Printed Overall Size 150mm X 300mm Sheet Printer on HP4500 UV Flat Bed Printed Overall Size 93mm x 300mm
Providing and Fixing of Photoluminescent 1mm Rigid PVC Based Sheet Containing Lumingen 3, As Base Chemical With Hight Internsite Luminous Glow Capacity Each Sign Which IS Required to BE MOUNTED ON 3MM ROUTER CUT Aluminium composite Panel With 25mm Boarder All Around Over the Size Of Photoluminescent sign ACP Shall Have Rounded Corners And Fixed On Wall Surface AS Per Drawing FIRE SAFETY SIGNAGES Overall Size 300mm X 300MM
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @0.40 litre/ sqm by the same membrane manufactured of density at 25° C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick.
Brick bats
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and fixing pressed steel door confirming IS code 4351 manufactured from commerical mild steel sheet of 1.25mm thickness includinghinges, jamb, lock jamb,bead and if required angle threshold of mild steel angle of section 50x25 mm or base ties of1.25mm pressed mild steel welded or rigidly fixed together by mechnical means, adjustable lugs with splitend tail to each jamb including steel butt hinges2.5mmthickwith mortar guards, lock strike-plate and shock absorbers as specified and applyingacoatofapprovedsteelprimerafterpre-treatmentof thesurface as directed by Engineer-in-charge: Profile C.Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including stainless steel butt hinges with necessary screws sqm
Providing and fixing factory made uPVC white colour sliding glazed window upto1.50m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60±0.2mm thick galvanized mild steel section made from roll forming process of required length (shape& size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40kg), G.I fasteners 100x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single/double glass panes,wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof SS wire mesh(Two nos. glazed & one no.wire mesh panels) made of (small series) frame 92x44 mm & sash 32x60 mm both havingwall thickness of 1.9±0.2mm and single glazing bead of appropriate dimension (Areaof windowupto1.75 sqm).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
Providing and fixing 40 X 20 X 1.6 MM RHS with MS angle 50 X 50 X 5 MM Fixed openable , fixed at spacing Clear Opening between two horizontal line 50 MM do all complete job as per direction of E.I
Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architech/ approving engineer, made of a high density fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a "Helmholtz" fluted perforation of 3mm width and 5mm/ 13mm/ 21mm of visible panel each. The edges of the panels shall be "tongue-and grooved" to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.7. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Architech/ Engineer-in-Charge. INSTALLATION : Install wooden battens (provided by others) of section 50x50mm or as approved by the Architect on the soild wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for chanelled woodworks provided by Armstrong over the lowest and second wooden batten at an oncentre distance of 600mm. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden mounlding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation team & installation should be carried out as per Armstrong recommended procedure. aS per archetrical design colur pattern arrangement in YOJANA BHAWAN MEETING HALL
Providing & fixing of 100% Natural Material-Magnesite (Hygroscopic & biologically sound binding agent) bonded wood wool Panel "Heradesgin-Superfine Sries Planks of 600 Mn"*1200Mm thickness made out of wood wool fibre of width 1Mm Fiber thickness mixed with Natural water & Magnesite (No-cement) with open & smooth surface texture. A completly harmless Envirement & Human Friendly & also a disposable or recyclable Material & can last for long span in building interiors As it has long lifespan & suitable for indoor conditions with relative air humidity of upto 90% Magnesite protects the wood cells against ageing & fungal attack. To achie upto NRC=1.00 it should be a clear gap of 200 Mm from wall slab along with the backing of Mineral of 50kg/M3. Edge Detail: AK 01 Heradesign Woodwool-Acoustical Wall Mounting System Solutions- Eccologically Sound Material with high machanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 &EN13964 with flying colors & A sustainable material (PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Environmental Product declaration). To ensure specification of tiles, Manufactures Test Certificate is required having completed site address & duly signed by Manufacture. Fixing & Substructure-Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel & Centre to centre scre Distrance support at 300Mm & Centre distance of Cross Profile would be at 600Mm & Main Profile at 900Mm CD Profile is made out of GI (Sections Profile 60/27/0.6m-0.6Mm Thickx60Mm Widthx0.27 Mm height). The Main Profile is in the legth of 3000Mm & to from a section of 600mmx1200mm. Heradesign Suprfine panels to be fixed on the wall with a minimum of 200 Mn void or gap with Galvanized screws of length 50Mm & Dia 4.5Mm with a blacking of Mineral Wool of density 50kg/m3 density (50mm thick).Installation should be carried out as per Armstrong/Knauf recommended procedure and designs approved by the Architec/ Engineer-in-Charge.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-charge. (The item includes cost of fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account)
Designing, fabricating , testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the buildings for all heights and all levels,including. a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thickness, aluminum cleats, sleeves etc., structural and weather silicone sealants, flashings, fire stop (barrier) cum smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including. b) Fabrication and supplying serrated M.S. hot dip galvanised / Aluminum alloy of 6005 T5 bracket of required sizes, sections and profiles etc. to accommodate 3 dimentional movement for achieving perfect vertically and fixing structural glazing system rigidly to the RCC / masonry / structural steel framework of building structure using stainless steel anchor fasteners / bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required capacity and in required numbers. c) Providing and fixing, two part pump fillied, structural silicone sealant and one part weather silicone compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with cutain glazing to make it watertight. e) Making provision for drainage of moisture / water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P , scafolding and other incidental charges including wastages etc,, enabling temporary structures and services , cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer -in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratary, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required , as per the Architectural drawings, as per item description, as specified as per the approved shop drawings and as directed by the Engineer-in-charge.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. All complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Providing and fixing in position collapsible steel shutters with vertical channes20x10x2mmandbracedwith flat irondiagonals20x5mmsize withtopandbottomrailofT-tron40x40x6mmwith40mmdiasteelpulleys completewithbots.nuts lockingarrangement stoppers handies including applying a priming coat of approved steel primer.
Providingandfixing1mmthickM.S.sheetdoorwithframeof40x40x6mm angle iron and 3mmMSgusset plates at the junction and corners.all necessary fittingscompletejncludingapplyingaprimingcoat of approved steel primer. Using M.S. angle 40x40x6 mm for diagonal braces
Applying priming coat:With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing bright finished brass door latch with necessary screws etc. complete: 300x16x5mm
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder :C.P. brass
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
75 MM dia
110 MM dia
Coupler 75 MM dia
Coupler 110 MM dia
Single Tee with Door 75 MM dia
Single Tee with Door 110 MM dia
Bend 75 MM dia
Bend 110 MM dia
Shoe Plain 75 MM dia
Shoe Plain 110 MM dia
75 MM dia
110 MM dia
15 MM dia
20 MM dia
15 MM dia
20 MM dia
25 MM dia
Horizontal
Vertical
Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing 600x120x5mmglass shelf with edges round off,supported on anodised aluminiumangle frame withC.P. brass bracketsandguardrail complete fixedwith40mmlongscrews, rawl plugs etc., complete.
Providing and fixing mirror of superior glass (ofapprovedquality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Constructing brick masonry chamber for underground C.I. inspectionchamberandbendswithbricksincementmortar1:4(1 cement :4coarsesand)C.I.coverwithframe(lightduty)455x610 mminternaldimensions, totalweightofcoverwithframetobenot lessthan38kg(weightofcover23kgandweightof frame15kg), R.C.C. topslabwith1:2:4mix(1cement:2coarsesand:4graded stoneaggregate20mmnominal size), foundationconcrete1:5:10 (1cement:5finesand:10gradedstoneaggregate40mmnominal size), insideplastering12mmthickwith cementmortar 1:3 (1 cement : 3coarsesand), finishedsmoothwithafloatingcoatof neat cement onwalls and bed concrete etc. complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making soake pit 2.5 dia m 3 m deep etc.
GI Metal False Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (NoiseReduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Boring/drilling bore well of 300 mm. dia. for casing/strainer pipe by suitable method prescribed in IS: 2800 (part-I) including etc. all complete jobs.
Supplying, assembling, lowering and fixing vertical position in bore well with 150 mm. dia. UPVC pipe medium well screen pipe etc. all complete jobs.
Supplying, filling and spreading gravels of size 5 to 10 mm. in recharge pit etc. all complete job.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm dia
Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm. to 2.0 mm. in the recharge pit over the gravel layer for all lead & lift etc. work all complete jobs as per the direction of E/I
Gravel packing in tube well construction in accordance with IS: 4097 including providing gravel fine / medium / coarse, in required grading and size as per actual requirement all complete as per direction of E/I.
Providing and fixing suitable size threated mild steel cap or spot welded plate to the top of bore well housing / Casting pipe, removable as per requirement, all complete for borewell of : 150 mm dia
Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tube well as per IS : 2800 (part I ), including necessary bots & nuts of required size complete. 150 mm clamp
Providing and fixing Ball plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (Part I) 150 mm dia
Providing and fixing 40 mm. dia. nominal bore G.I. union in G.I. pipe line cutting and threading the pipe and making long screws etc. all complete jobs.
Supplying and fittings 2.00 HP Submersible water pump with starter cables etc. all necessary fitting etc. all complete jobs.
Point
Point
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
meter
meter
Meter
Meter
Metre
Metre
Metre
Metre
Metre
Metre
Metre
per mtr
BOQ AMOUNT FROM ABSTRACT:
Difference is cost of Soil Test
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-05 SBD TERMS AND CONDITION DOCUMENT.pdf
NIT • 2.21 MB
NIT-5 SBD_25-26_JEHANABAD.pdf
NIT • 0.84 MB
NIT-05 SBD TERMS AND CONDITION DOCUMENT.pdf
NIT • 2.21 MB
BOQ Yojna Bhawan.xlsx
NIT • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .