RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate Modular Toilet ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Mode of Supply Knocked Down To Be Assembled At Consignee Site By The Seller * Number of Compartments 1 - seater modular toilet 1 - seater modular toilet
Required2 - seater modular toilet
Required3 - seater modular toilet
Required4 - seater modular toilet
Required6 - seater modular 1/11 toilet
Required8 - seater modular toilet
Required10 - seater modular toilet Type of WC Indian with ceramic pan Indian with ceramic pan
RequiredIndian with SS pan
RequiredIndian with FRP pan
RequiredIndian FRP pan with integrated facility(With FRP floor)
RequiredEuropean with ceramic pan
RequiredEuropean with SS pan Number of WC 1 * Number of Bathrooms 1 * Number of Urinals 2 * Water facility By mean of overhead tank(Capacity 200Ltrs) By mean of overhead tank(Capacity 200Ltrs)
RequiredBy mean of overhead tank(Capacity 300Ltrs)
RequiredBy mean of overhead tank(Capacity 500Ltrs)
RequiredBy mean of overhead tank(Capacity 750Ltrs)
RequiredBy mean of overhead tank(Capacity 1200Ltrs)
Requiredwith running water connection
RequiredDirect connection from external supply Wash basin 1 No. in each WC unit(inside) * Sewage facility Twin Leech pit with inspection chamber Sludge tank (capacity-400ltrs) with 100mm outlet facility through butterfly valve and hose pipe(For 4-seater)
RequiredSludge tank (capacity-600ltrs) with 100mm outlet facility through butterfly valve and hose pipe(For 6-seater)
RequiredSludge tank (capacity-1400ltrs) with 100mm outlet facility through butterfly valve and hose pipe(For 8-seater)
RequiredSludge tank (capacity-2000ltrs) with 100mm outlet facility through butterfly valve and hose pipe(For 10-seater)
RequiredProvision for directly connected to septic tank/sewage
Required2/11 Twin Leech pit with inspection chamber
RequiredSludge tank (capacity-200ltrs) with 75mm outlet facility through butterfly valve and hose pipe(For 1-seater and 2-seater)
RequiredSludge tank (capacity-400ltrs) with 75mm outlet facility through butterfly valve and hose pipe(For 3-seater and 4-seater) ventilation One No. One No.
RequiredTwo No.
RequiredFull size ventilation above door plus half size ventilation on other side for cross ventilation Top(roof) shape Flat * Projection of Roof 50mm projection on all the four sides * Installation and commissioning To be done by seller * Plumbing and Sanitation fitting connection To be done by seller * Electrical connection To be done by seller * Waste extraction Fitting To be done by seller * Leech pit provision Yes Yes
RequiredNo Civil foundation Required to be provide by seller No foundation Required
RequiredRequired to be provide by seller
RequiredRequired - to be provide by consignee himself FRAME MATERIAL Bottom frame material 75mm X 37.5mm C- channel MS - 5mm X 37.5mm C-channel MS - 40mm X 40mm X 5mm(thick) MS angle - 40mm X 40mm X 5mm (thick) MS Tee - 35mm X 35mm X 5mm (thick) MS angle and 25mm X 25mm X 3mm (thick) MS angle for 4-seater/6 -seater/8-seater and 10-seater * 3/11 Side panel frame material No side frame structure 35mm X 35mm X 5mm(thick) and 5mm X 25mm X 3mm(thick) MS angle (for 4-seater 6-seater/8-seater & 10-seater)
RequiredNo side frame structure Top(roof) frame material No roof frame structure 40mm X 40mm X 5mm(thick)-35mm X 35mm X 5mm(thick) and 25mm X 25mm X 3mm(thick) MS angle
RequiredNo roof frame structure Top(roof) support frame structure No support structure 40mm X 5mm(thick)
Required35mm X 5mm(thick)
Required25mm X 3mm(thick) MS flat
RequiredNo support structure Partition frame material No partition frame structure 35mm X 35mm X 5mm(thick)
Required25mm X 25 mm X 3mm(thick) MS angle
RequiredNo partition frame structure Ventilation frame material No ventilation frame material 25mm X 25mm X 3mm(thick) flat MS
Required3 sides zero spangled cold rolled 120 GSM galvanised(galvano) powder coated louver panel for cross ventilation with EPS insulated panels(provision for natural light above door)
RequiredNo ventilation frame material Door frame material Zero spangled cold rolled 120 GSM galvanised(galvano) powder coated with necessary stiffeners and aluminium accessories(2 AI handles - 1 AI tower bolt - 1 AI L-drop(steel sheet thickness - 0.6mm 275 MPA) 50mm X 25mm of 14-16gauge rectangular MS hollow pipe
Required50mm X 25mm of 14-16gauge rectangular SS hollow pipe
RequiredZero spangled cold rolled 120 GSM galvanised(galvano) powder coated with necessary stiffeners and aluminium accessories(2 AI handles - 1 AI tower bolt - 1 AI L-drop(steel sheet thickness - 0.6mm 275 MPA)
RequiredNo door frame material 4/11 Support material for Door panel fixing No support material Aluminium U-channel of 18gauge
RequiredSS U- channel of 18gauge
RequiredNo support material Door hinges(two numbers) 75mm size with 1.2-1.5mm thickness MS 75mm size with 1.2-1.5mm thickness MS
Required75mm size with 0.6-0.8mm thickness SS
Required75mm size with 1.2-1.5mm thickness Chrome plated Tank holder frame material 1125mm X 820mm outer ring(tubular structure)-MS 25mm X 3mm(thick) MS flat
Required25mm X 3mm(thick) SS flat
Required1125mm X 820mm outer ring(tubular structure)-MS Unit understructure NO legs base Supported by 4-legs of size 75mm X 37mm C- channel MS angle
RequiredSupported by 4-legs of size 75mm X 37mm C- channel SS angle
RequiredNO legs base Stairs frame material NO stairs 25mm x 25mm X 3mm MS angle
Required25mm x 25mm X 3mm SS angle
RequiredNO stairs Stairs material No stairs material 25mm X 3mm MS flat
Required25mm X 3mm SS flat
RequiredNo stairs material Door Tee material No door Tee material 40mm X 40mm x40mm X 5mm(thick) MS Tee
Required40mm X 40mm x40mm X 5mm(thick) SS Tee
RequiredNo door Tee material PANEL MATERIAL Side panel material Zero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40mm thick EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
RequiredZero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40mm thick EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA)
RequiredOutside paneling of 18 gauge MS sheet and inside paneling of 18 5/11 gauge aluminum sheet(single partition
Requiredcorrugated sheet
RequiredFitted with plastic light weight LLDPE roto molded Top(Roof) panel material Zero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40-70mm thick taper roof EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
RequiredZero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40-70mm thick taper roof EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA)
Required4mm poly carbonate sheet fitted on top
RequiredFitted with plastic light weight LLDPE roto molded Door panel material Zero spangled cold rolled 120 GSM galvanised(galvano) powder coated with necessary stiffeners and Aluminium accessories (2 AI handles-1 AI tower bolt-1AI L-drop and steel sheet thickness 0.6mm 275MPA) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
RequiredZero spangled cold rolled 120 GSM galvanised(galvano) powder coated with necessary stiffeners and Aluminium accessories (2 AI handles-1 AI tower bolt-1AI L-drop and steel sheet thickness 0.6mm 275MPA)
RequiredOutside paneling of 18 gauge aluminum sheet(corrugated sheet)
RequiredFitted with plastic light weight LLDPE roto molded partition panel material Zero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40mm thick EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA) 5mm thick ply core sandwich with 1mm thick FRP from both sides(5+1+1mm)
RequiredSingle layer 3mm thick FRP
RequiredZero spangled cold rolled 120 GSM galvanised(galvano) powder coated 40mm 6/11 thick EPS panel(EPS Density-16Kg/CuM EPS thickness-38mm and steel sheet thickness 0.6mm 275MPA)
RequiredFitted with plastic light weight LLDPE roto molded Floor material(inside cubical) Anti skid tile finish floor inside toilet 5mm thick FRP material
Required2-3mm thick SS material
RequiredFitted with plastic light weight LLDPE roto molded
RequiredAnti skid tile finish floor inside toilet DIMENSION size of each cubical(LXWXH) ± 25mm 1220mm X 1220mm X 1980mm 890mm X 840mm X 1980mm
Required915mm X 915mm x 1980mm
Required1220mm X 915mm X 1980mm
Required915mm X 435mm X 1955mm
Required1220mm X 1220mm X 1980mm
Required1830mm X 1220mm X 2050mm (For physically disabled) Door size(WxH) ± 20mm 1790mm X 655mm(Steel sheet thickness - 0.6mm 275MPA) * Ventilation size(WXH) ± 10mm 838mm X 150mm(above door) plus 838mm X 75mm(opposite side) * Partition height ± 20mm NO partition 1830mm
Required1900mm
RequiredNO partition Single pan size ± 10mm 580mm X 440mm with built in platform/footrest * Stairs size ± 10mm NO MS stairs 610mm X 230mm having 1-step
Required610mm X 230mm having 2-step
Required610mm X 230mm having 3-step
RequiredNO MS stairs Leg height ± 20mm 455mm * MISC Door locking bolts Size 100mm of MS * Tower bolt locking Tower bolt of MS size 75mm * Overhead tank material Made of PVC made of double layer HDPE sheet
Requiredmade of three layer HDPE sheet
RequiredMade of PVC
RequiredNO tank 7/11 Wash basin material made of SS 304 * WC material made of Ceramic * Towel rail/ring NO towel rail * Cloth hook NO cloth hook * P-trap material made of PVC(75mm) * Footrest(WC) material made of SS 304 integrated with Indian WC and floor * Sewage tank material Twin Leech pit with insepction chamber Sludge tank made of FRP 4mm thick (for 4-seater/6- seater/8-seater and 10-seater)
RequiredTwin Leech pit with insepction chamber
RequiredNO sewage tank Mirror Size NO mirror * Electric provision By mean of connection from main line By mean solar energy
RequiredBY mean of battery
RequiredBy mean of connection from main line
RequiredNO electric provision Water supply connection UPVC pipe connection with all toilet interconnecting * Seat cistern fitting By PVC flush pipe to toilet seat * Soap stand Plastic made * Tap material PVC push cock * Base floor surface(inside) To be suitably slanted towards WC for proper drainage(for Indian WC) To be suitably slanted towards WC for proper drainage(for Indian WC)
RequiredN.A Provision for vent pipe From sludge tank/septic tank * Raised platform for passage Width of passage 1220mm and height of passage above ground level 225mm antiskid block finish on passage only Width of passage 1220mm and height of passage above ground level 225mm antiskid block finish on passage only
RequiredN.A Level indicator provision To be provided in every sewer/sludge tank to know the level of sludge and plan to get it evacuated * CIVIL FOUNDATION DETAILS Brick foundation size 200mm X 200mm with depth of 200mm from 200mm X 200mm with depth of 200mm from 8/11 ground level for anchor/column locations ground level for anchor/column locations
RequiredN.A Pocket to be filled With PCC of 1:2:4 ratio after grouting of steel element of structure With PCC of 1:2:4 ratio after grouting of steel element of structure
RequiredN.A Plinth height 300mm with 125mm brick plus 1:5 mortar 300mm with 125mm brick plus 1:5 mortar
RequiredN.A Platform size 1125mm X 1500mm 1125mm X 1500mm
RequiredN.A Soling height 75mm by single brick flat 75mm by single brick flat
RequiredN.A Floor casting 75mm thick PCC of 1:2:4 ratio above brick flat soling 75mm thick PCC of 1:2:4 ratio above brick flat soling
RequiredN.A Outside plinth plaster 15mm thick on brick work with CM 1:5 15mm thick on brick work with CM 1:5
RequiredN.A Stairs dimension Two Nos. stair of size 250mm(W) X 900mm(L) X 150mm(H) Two Nos. stair of size 250mm(W) X 900mm(L) X 150mm(H)
RequiredN.A TWIN LEECH PIT Twin leech pit with inspection chamber 1000mm Dia and 1000mm deep 1000mm Dia and 1000mm deep
RequiredN.A Construction of leech pit made out of 40-50mm thick concrete rings/brick work with sufficient holes made out of 40-50mm thick concrete rings/brick work with sufficient holes
RequiredN.A Top cover 75mm RCC slab(1:4:8 C:S:A) 75mm RCC slab(1:4:8 C:S:A)
RequiredN.A Rings material MS * Dimension(inside) of one inspection chamber 375mm X 375mm X 300mm(depth) 375mm X 375mm X 300mm(depth)
RequiredN.A Base of chamber 75mm thick PCC in 1:5:10 75mm thick PCC in 1:5:10
RequiredN.A Finishing of chamber(inside surface) 10mm thick cement plaster in 1:4 10mm thick cement plaster in 1:4
RequiredN.A Pipe connection To be between Toilet structure-inspection channel and leech pit To be between Toilet structure-inspection channel and leech pit
RequiredN.A COLOUR & FINISH Colour of cabin As per buyer's choice * Finish With Primer and Paint * WARRANTY Warranty period in number of years 1 1
Required2