Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹43.4 L Quoted ₹43.5 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹46.1 L+₹2.6 L (6.07%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹46.1 L+₹2.6 L (6.07%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹46.7 L+₹3.3 L (7.48%)Rejected-Finance | ₹46.7 L+₹3.3 L (7.48%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹47.1 L+₹3.6 L (8.35%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹47.1 L+₹3.6 L (8.35%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹48.4 L+₹4.9 L (11.3%)Rejected-Finance | ₹48.4 L+₹4.9 L (11.3%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
10 Dec 2022, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION / ALTERATION TO COMPOUND WALL ALONGWITH THE ROAD OF TRV POND OPPOSITE SITE AND PROVISION OF STORM WATER DRAIN AT TRV AND PROVISION OF HARSTANDING WITH STONE PITCHING AND PAVER BLCOK WORK IN CG RHQ AND CG DHQ PREMISES UNDER GE HADDO, PORT BLA
2022_MES_564165_1
8694/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and category a(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹95,800
Yes
28 Dec 2022
19 Nov 2022
17 Dec 2022
19 Nov 2022
10 Dec 2022
5 Dec 2022
21 Nov 2022 - 30 Nov 2022
Amount
Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed
M&L for PCC type D2 (1:4:8) (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for cement concrete (1:2:4) type B2 (using 40mm graded stone aggregate) as in channels or drains complete all as specified and as directed.
Returning filling in incl spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soil complete all as specified and directed.
Removal excavated soil to a distance n. exc. 50m and deposited where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for Forming fair finished drain using extra cement complete all as specified and directed
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M & L Rendering 10mm thick on fair faces of brick work or concrete surfaces finished with even and smooth without using extra cement in CM 1:4 complete all as specified and directed.
M&L for rendering in two layer i.e. 5mm thick in CM 1:4 including with or without mixing water proofing compound over 10mm thick in CM (1:6) on concrete/block masonry surfaces and finished even and smooth without using extra cement on all as specified. (Note WPC shall be measured and paid separately)
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slabs for drain covers set in cm 1:4 all as specified and directed
Supply only integral water proofing compound.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns/beams, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No.14 above but as in stirrups / spacers/ binders complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed blusters, walk ways, railings framed work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for glossy finished heavy duty chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
S&F 150mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
M&L for preparation on newly plastered wall surface and applying two coats of cement base paint complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of pre-cast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M& L for RCC M-20 concrete (using 20mm graded stone aggregate) as in foundation including raft footings foundationbeams plinth beams bases slabs under-reamed piles and mass concrete etc as specified.
S & F stainless steel tubing of any diameter of circular, square or rectangular in shape of grade AISI-316 (type Austenitic anticorrosive in nature) as in railings / grills / designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixing in any type of location incl taking down old railing of any description complete all as specified and as directed.
M&L for preparation on newly plastered external wall surface and applying two coat of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over a coat of primer of the same manufacturer as that of paint complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard) complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated external wall surface by scrapping, washing, cleaning etc and applying two coat of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over a coat of primer of the same manufacturer as that of paint incl filling cracks, holes using wall care putty complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard).
M&L for PCC 1:2:4 type B1 (20mm graded stone aggregate) as in surface channel and drain & benching of manhole and finishing even and smooth without using extra cement complete all as specified and as directed
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard dense soil complete all as specified and directed.
M & L for hardcore of gauge exc 63 mm but n.exc 100mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders complete all as specified and directed,
M&L for Cement concrete P.C.C (1:4:8) Type D2 (using 40 mm graded aggregate) as in sub base 75 mm thk complete all as specified.
M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) all as specified.
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in cooping in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, inishing and sweeping extra sand complete.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
M&L for 200mm thick size of boulder 90mm to 150mm boulder pitching grouted by cement and sand mortar (1:6) Complete all as per specified as and directed
Taking down old unserviceable LT XLPE cable of any size and any capacity all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 10 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material and including taking down old u/s cable complete all as specified and as directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engg-in-Charge before the cable is laid. (ii)Excavation earth work will be measured and paid separately Make : Gloster / Havells / Anchor / Polycab / Finolex.
M&L for HDPE DWC (Double wall corrugated) pipe of size 40mm (Outer diameter) x 32mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make : REX POLYEXTRUSION LTD/ Tirupati plastomatics Pvt Ltd
S&F against repairs LED Bollard with round top 9/10 Watts, 220V, 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation, 3 core 2.5 Sqmm multistranded copper conductor drawn through and including 25mm dia rigid PVC conduit from one light to other (approx distance 30 metres) with cable connectors including taking down old unserviceable one complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LBLSN-10-CDL or equivalent in BAJAJ/ HAVELLS/ PHILIPS 58167 YOB PEDESTAL/C&S Cat Part No. Canis 10W
S&F LED post top luminaire, outdoor type (Prince opera midi) of 240 Volts, 50Hz, 40 watt capacity, IP 65 protection including mounting on 63mm dia galvanised medium grade pipe of 2.0 metre height from GL with necessary PCC (1:2:4) type B1 foundation and connecting up with and including 3 core 2.5 Sq mm multistranded copper conductor cable drawn through 25 mm dia rigid PVC conduit from one light to other (Approx distance between two posts 30 metres) including taking down old unserviceable one complete all as specified and as directed. MAKE:CROMPTON GREAVES Cat part No. LPTO-40-CDL-M or equivalent in PHILIPS/ C&S Cat Part No. LTGLC40WHPLED/W
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 70 Watts capacity, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary brackets of suitable size, bolts, nuts and washers as required fixing on high mast of 16 mtr of power factor >0.9 and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable any type of light fitting complete all as specified and as directed. MAKE: PHILIPS Cart part No.BVP182 LED70 CW/NW/WW or equivalent in CROMPTON GREAVES/ C&S/ LUKER
S&F FRP pole box of size 170x170x105mm consisting of 50 Amps, 4 pole connector - 1 No. and MCB, SP, 16 Amps, 10 KA - 1 No. with necessary clamps, bolts, nuts and washers including taking down old unserviceable one complete all as specified and as directed. MAKE of FRP Box: Hansel/ SINTEX Cat No. GS-JB-1414 MAKE of MCB: L&T/ HAVELLS/ LEGRAND
S&F LED street light fittings of high power LED, IP 66 protection and unique power lens to ensure uniform light distribution, higher spacing between poles and maintenance free system of LED of 70 Watts capacity, 220 V, 50 Hz including necessary brackets of suitable size, bolts, nuts and washers as required and including taking down old unserviceable halogen / any type of light fittings complete all as specified and as directed. MAKE: C&S Cat Part No. LTESSI70WLED / PHILIPS Cart part No.BRP409 LED CW 074 CW HE MR FG S1 PSU GR or equivalent model of CROMPTON GREAVES/ HAVELLS/ LUKER
M&L for street light mounting bracket made up of 32mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer including taking down old u/s brackets complete all as specified and directed.
SKV Engineering
V KARTHICK
M/s Ramesh Lal
M/s K Moorthi
CARTWHEEL CONSTRUCTION
A PALANI
SHUBHAM SHANKAR GAIKWAD
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .