Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹59.0 L
EMD Value
₹1.2 L
Closing Date
2 Jan 2023, 2:00 pmClosed
Executive Engineer Electric Division Batote
Executive Engineer Electric Division Batote
SUPPLY ERECTION TESTING COMMISSIONING FOR CREATION OF 16X25 KVA SUB STATIONS AND 4X63 KVA SUBSTATIONS AS RECOMMENDED BY HONBLE DDC MEMBER BANIHAL B UNDER UT CAPEX BUDGET 2022 23 UNDER THE JURISDICTION OF ED BATOTE
2022_PDD_200417_1
e NIT No 32 of 2022-23
Open Tender
Electrical Works
Turn-key
60 days
Banihal
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer Electric Division Batote
₹1.2 L
Yes
10 Jan 2023
22 Dec 2022
2 Jan 2023
22 Dec 2022
2 Jan 2023
22 Dec 2022
Amount
Creation of 16x25 KVA Sub-stations at Thandishah (Zaidpora), Famber Nallah, Arpora Upper Doligam A, Naikpora Bohrigam Pyt Doligam Upper B, kadarah wagan (Sunda) , Kakarpora, Channar Bankoot, Tatnihal Upper (Dungatra), Amkoot (Khoura W.No 5), Changaldar Rehmanpora, Chundpora Chapnari, Lonepora Chapnari upper, Gilla Basti Naikpora, Hajipora (Budgam), Naikpora (Thachi) and Mochi Mohalla Pyt Tantraypora
11/0.433 KV, 25 KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelaen) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
25 mm Sq Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts
Fuse Set
Cement Bottoming 1:2:4 mix as per REC standards, 5 cum/pole.
Earthing of Sub-station
Galvanised Stay Set Complete
Creation of 4x63 KVA Sub-stations at Khoura Gujjarbasti Doligam, Hinjhall Hargam, Khandpora Naikpora Thachi and Upper Gam Tantraypora.
11/0.433 KV, 63 KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2.
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelaen) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70 mm Sq (2 Ckt)/185 mm Sq ( 2 Ckt) Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts
Fuse set
Earthing of Sub-station
11 KV Polymeric composite Pin Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
Wedge Connectors/PG Clamps
Danger Plates with Clamps
Sundry items like aluminium lugs, Jumpers, binding Tape etc.
GI Barbed Wire for Anti Climbing
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Galvanised Stay Set Complete
MR INFRA ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .