Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.5 CrAccepted-AOC 6 BIPLABI DINESH MAJUMDER SARANI 1ST FLOOR FLAT 1B NEW ALIPORE KOLKATA 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹58.5 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹59.8 CrRejected-Finance | ₹59.8 Cr | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹64.0 CrRejected-Finance | ₹64.0 Cr | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹64 CrRejected-Finance | ₹64 Cr | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹68.6 CrRejected-Finance 421 4TH FLOOR TOWER A 2 SPAZE ITECH PARK SECTOR 49 SOHNA ROAD GURGAON | GURUGRAM | HARYANA | 122001 | ₹68.6 Cr | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹64 Cr
EMD Value
₹35.3 L
Closing Date
7 Nov 2022, 6:00 pmClosed
BRIG AJAI SINGH CHONKER CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
PROVN OF STORAGE ACCOMODATION PANAGARH PHASE II AT PANAGARH
2022_MES_550805_1
89032/E8
Open Tender
Civil Works
720 days
GE (P) PANGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) PANAGARH
₹35.3 L
27 Dec 2022
8 Sept 2022
9 Nov 2022
8 Sept 2022
7 Nov 2022
13 Oct 2022
Amount
NOTE (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDINGS WORKS as listed in Schedule ‘A’ Part-I.
Lumpsum price workedout by the tenderer for EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II.
Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III.
Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIFICATION / ADDL PUMP SET FOR FIRE FIGHTING AND ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV.
Lumpsum price workedout by the tenderer for ENTERNAL WATER SUPPLY & ADDL PUM SET FOR FIRE FIGHTING as listed in Schedule ‘A’ Part-V.
Lumpsum price workedout by the tenderer for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-VI.
Lumpsum price workedout by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.
Lumpsum price workedout by the tenderer for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-VIII.
Lumpsum price workedout by the tenderer for RCC DUNNAGE BLOCKS as listed in Schedule ‘A’ Part-IX.
Lumpsum price workedout by the tenderer for PCC FIRE BREAK as listed in Schedule ‘A’ Part-X.
Sch 'A' Part-XI (MISC B&R AND E&M ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Preparation of BIM Model to include the following :- (a) Preparation of BIM Model on the Basis of approved Architectual Stuctural MEP Drawings Provide by the Deptt. (b) Preapation of Architectural BIM Model-3D. (c) Preparation of MEP BIM Model.Clash Detection and removal to be performed by making combined BIM Model for Architectural Structural & MEP drawing. (d) Estimate from derived BIMS Quantities and Specification (On Excel Sheet and on relevant BIMS Software. (e) Submission of yardwstick for bldg work as per Stages. Plinth area of 1 X lgloo Storage shed is 686.29 Sqm (approx) (f) Bim Deliverable will be made avbailable in CD as follows :- (i) Site Model (ii) Civil and infrastructure Models (iii) Architectural Model (iv) MEP Model (v) BIM Drawing in AutoCAD and PDF (vi) Submission of 3min BIM enabled work through considering external and internal views.
Post tender stage : upload yard stick (With stages) in a suitable database formate in eMBR module to facilitate entry of measurement records by GE (or designated staff) and accessible to appointments in the MES hierarchy. The website will also generated reports such as on the format of RAR abstract and MB to facilitate payments. the deliverables are login names :- Notes (a) The rates quoted are inclusive of GST (b) Approval yardstick will be intimated to consultant approved by Acceptig Officer to uploading the same in eMBR formats. (c) The website will be created as per GOI instruction on the subject and maintained by the Venor during the period of construction maintained in the Work CA. The Website will facilitate entries for recording measurements and generate abstract, MB report for releasing RAR Payment during construction stage. (d) Rate quoted in item above includes remote training (2 Sessions) During construction tage for facilitating use of the website and technical support during construction stage. (e) all deliverable will be submitted by mail in soft Copy only. (f) All for item of maintained above, constitute a single package and cannot be further subdivided into sub package. Note : Consultant shall give his advise / opinion or may be called for site visit for any technical issues arising out during execution till completion of project.
S&F Sign board of Size 1200 x1200mm, made up of SS steel tube 50mm dia and 3mm thick fibre sheet fixed both side of the frame with making if Sign or Text with florescent tape/colour as directed by Engr in Charge including fixing of the same in PCC in ground.
INTERNAL ELECTRIFICATION
M&L for point wiring with Halogen Free Flame Retardant (HFFR), with unilay construction copper conductor 2.5 sqmm unsheathed and insulated multistrand 1100 volts grade cable drawn through flame proof ERW metalic conduit of size 20 mm dia with all accessories such as Tee, elbows , beds and junction boxes including 2.5 sqmm wire as earth wire connected to common earth dolly to control 05 Nos of flame proof lights by one flame proof switch complete all as specified and directed.
M&L for point wiring with Halogen Free Flame Retardant (HFFR), with unilay construction copper conductor 4.0 sqmm unsheathed and insulated multistrand 1100 volts grade cable drawn through flame proof ERW metalic conduit of size 20 mm dia with all accessories such as Tee, elbows , beds and junction boxes including 4.0 sqmm wire as earth wire connected to common earth dolly complete for Flame proof socket 16 Amp all as specified and directed.
Supply and fixing flame proof LED light fitting 40 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 65 degree of protection as per IS-2147 (1962) of die cast aluminum alloy LM-6 construction, light grade epoxy powder coating finish of shade number 631 as per IS-5 having provisioning of one number internal earth and two numbers external screws of M4/M5 size 'O' ring endless neoprene rubber gasket, stainless steel hardware, two number 3/4 inch cable entry, cable glands, all internal electrical components pre-wired, inside white and outside light gray, internal driver type epoxy powder coating, clear heat resistance well glass complete all as specified.
Supply and fixing flame proof cum water proof LED bulk Head light fitting of 20 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 66 degree of protection, cast aluminum alloy material and heat and impact resistance toughen 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connected up with three core flexible copper conductor cable with suitable size complete all as specified.
Supply and fixing flame proof distribution board, flame proof as certified by CMRI, TPN 4 way with DIN rail, suitable for isolators, MCBs and ELCBs, suitable for group-I, IIB as per IS 2148 (1981), IP-65 as per IS-2147 (1962), cast aluminium alloy LM-6 conastruction, light gray epoxy shade No 632 of IS-5 powder coating having provision for one number internal and two number external screws for earthing, also having 'O' ring neoprene rubber gasket, hardware in external steel construction having four numbers 1/4 inch ET bracket incomming and 12 numbers 3/4 inch ET outgoing, cable entry from bottom side complete all as specified and directed. Note:- Isolators, MCBs and ELCBs shall be measured and paid separately.
Supply and fixing flame proof/weather proof rotary switch with cable termination box LM6 with MCB TP, 25 Amp, 440 volt on/off complete all as specified and directed. (02 Nos for each storage building for EOT crane)
Supply and fixing MCB SP 6-32 Amps, 230 Volts complete all as specified and as directed.
EXTERNAL ELECTRIFICATION AND STANDBY ELECTRIC SUPPLY
Supply, laying & testing PVC insulated, PVC sheathed electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade to connect street light to junction box complete all as specified and as directed.
Supply, install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3.15 mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 400Amps and necessary foundation work and comprising following:-
Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3.15 mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 200Amps and necessary foundation work and comprising following:-
Supply, fabricated and installation of bus bar of box made out of 3.15 mm thick CRCA sheet of size 0.8 x 0.5 x 1.0 m height pedestal type. Padestal height 1 mtr from the ground level by MS angle iron 40 x 40x6 mm front opening with single leaf shutter and rubber gasket panel shall be grouted on including PCC 1:2:4 type B1 block. Bus bar box shall be painted with two coats of synthetic enamel paint over a coat of red oxide premier and fixing of 4 Nos aluminium bus bar 40 mm x 8 mm fixed on insulator incl provisioning of cable gland of suitable size, cable lugs all as required for cable connection complete. (These shall be used in lieu of straight through joint).
Supply and install of fire extingusher water CO2/storage pressure type 9 litre capacity (IS940/6324).
Supply and install of fire extingusher dry chemical powder (ABC) type, 10 Kg capacity (IS: 13849, 14609).
Supply and fixing LED street light fittings on poles of capacity 45 watts, High pressure die cast aluminium, IP 66 Rating, front cover made of toughened Clear Glass, suitable for pole mounting with bracket arm 40mm dia, GI light grade pipe up to 1.4m long, bend to required shape, clamp 40mm x 6mm of required length including nuts & bolts fixed on street poles complete all as specified. Make: Havells; Cat Part No-ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent in Crompton/Surya.
Supply and fix Junction box with terminals of size 155 x 210 x 92mm or nearest higher size made of polycarbonate body with IP 66/67 degree of protection, dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block and PVC glands for cable entry complete all as directed. Make: Hensel; Cat No-KF1616G/ Sintex
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
EXTERNAL WATER SUPPLY & ADDL PUMP SET FOR FIRE FIGHTING
Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-7”, 250 mm nominal dia complete all as specified and as directed.
Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-7”, 100 mm nominal dia complete all as specified and as directed.
Supply and laying of pipe ductile Iron, flanged type, Class “K-9”, 250 mm nominal dia complete all as specified and as directed.
Material & labour for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing,decreaing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross for DI pipe upto 150 mm bore complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN with brass spindle, 100 mm dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN with brasss spindle, 150 mm dia complete all as specified and as directed.
Supply and fix Foot Valve conforming to IS 4038, of size 150 mm (6”) dia complete all as specified and directed.
Supply and fix Strainer Y type conforming to IS, of size 150 mm (6”) dia complete all as directed.
M&L for Construction of brick masonry chamber of 90 cm x 90 cmx 90 cm [internal dimensions] suitable for 100 mm/150 mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with sub class ‘B’ brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
M&L for Construction of brick masonry chamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 25mm/50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with sub class ‘B’ brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
Supply, install, testing and comissioning of centrifugal monoblock pumpset self priming having a discharge of 2850LPM at a head of 12 mtr coupled with 10 HP/7.5 KW motor suitable for AC 50 Hz, 3 phase 415 volts supply including suitable size frame and MS foundation bolts, nuts and washer and covered shed by means of MS channel, CGI sheet, etc and including connecting the electrical connection by suitable size copper cable drawn through and including PVC rigid conduit accessories on wall or on floor complete connected to common earth dolly all as specified and as directed by Engg - in - Charge.
Supply and fix automatic star delta starter suitable for upto 10 HP monoblock centrifugal pump set complete all as specified and directed. Make :- Havells Cat Part No. IHHASDRA* or its equivalent in C&S/L&T/BCH
Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 100Amps and necessary foundation work and comprising following:- (a) Incoming MCCB, 4 pole, 40 Amps, 415 Volt AC, 25 KA rupturing capacity --01 No.
ROAD/PATH/CULVERT/PCC FIRE BREAK
M&L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e 10 % Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed by Engr-in-Charge
M&L for 100mm thick dry lean concrete (DLC) with coarse and fine agg confirming to IS 838, size of agg not exc 40 mm graading & other parameters as per table 600-1of MORTH , IRC SP-49 specifications design mix minimum cement content shall not less than 10 MP at 7 days , MIxed in batching plant, transported to site, laid with sensor pavor over a prepared base incuding spreading and compacted by using double drum smooth sealed 80-100 KN static vibartory roller including necessary form work finishing etc (Construction expansion joints shall be spaced as per paving concrete longitudnal & traverse joint all as specified & directed.
LIGHTING PROTECTION
Supply and fixing GI pipe medium grade 32 mm dia with anchor plate 3 mm thick 50x50 mm welded at the bottom grouted on bed block including 3 mm thick MS cap complete with 12 mm bore drilled on the MS cap and fixing of one GI nut duly welded on the inner surface of the cap suitable for fixing of the air termination rod. Note: Bed block will be measured and paid seperately all directed.
Material & Labour for precast PCC type C1 1:3:6 (nominal mix) using 20 mm stone aggregate bed block of size 300x300x450mm height for fixing GI pipe 32 mm dia medium grade with air termination rod vertically all as specified.
DIGITEL TEMP & HUMIDITY METER
Supply, testing, commissioning and fixing of Temperature & Humidity Data Logger with the following specifications:- (a) Max / Min : Temperature reading over 0 to 60% RH : 5% to 15% (b) Measurement ranges by PC with USB interface with data card and LCD monitor (c) Memory for 32700 readings (16350 temperatures and 16350 humidity readings) with long life battery pack with accessories including locking arrangement complete with fixing on wall
DG SET
Supply, install, test and commission of diesel engine driven generating set 100 KVA(80 KW) , 415V AC 3 Phase 4 wire 50HZ supply, (voltage regulation at ± 1 % of rated voltage from no load to load with Electronic Regulator) 1500 RPM, 0.8 PF lagging complete with standard AMF control panel, sturdy welded channel iron common base frame both for prime mover and alternator, anti- vibration pads and necessary RCC foundation etc, as specified by the manufacturer and comprising of following :-
(a) Prime mover shall be water cooled type, 1500 RMP under STP conditions to drive the alternator complete with standard fittings, electric start arrangement including maintenance free batteries with connecting leads and terminals and charging system for batteries. Over load capacity shall be 10% for 1 hour in 12 hours operation. The prime mover shall have the following features: (i) Fuel pump as supplied by OEM (ii) Electronic governor (iii) Turbo charger, pulse tuned exhaust manifold, stainless steel exhaust flexible connection (iv) Radiator, coolant inhibitor, Low temperature after cooling (LTA) (v) lub oil cooler (vi) Full flow paper element filters-fuel,lube oil and by-passs (vii) Dry type replaceable paper element for air cleaner with restriction indicator (viii) Fly wheel housing & fly wheel to suit single bearing Alternator (ix) Starting Electric battery charging alternator (x) first fill lub oil
(b) Fuel Storage Tank of adequate capacity for 12 hrs run along with cover, locking arrangement, level indicator in litres, inlet strainer, fuel out let, air vent, drain plug, incl MS Staging to the required height, fuel line up to DG Set with MS pipe of suitable dia, Fuel transfer pump with By pass connecting system all as per Manufacturer's recommendations. (c) Alternator shall confirm to IS-4722 of 1968 in SPDP constructions with IP23 degree of protection, Class 'H' insulation for Stator, Rotor and Exciter. Brashless excitation system with exciter filed supplied from the solid state regulator. (d) Acoustics enclosure for DG set as per manufactoure's recommendations. The job includes for necessary foundation as per manufacturer's recommendations. It shall meet CPCB norms of 75 db at 1 m at 75% load under filled conditions.
(f) Microprocessor based control panel capable of (i) Engine electronic governing (ii) Gen set metering parameters like lube oil pressure, coolant temperature, engine speed(RPM), Run hours, DC Voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, Power factor (iii) Engine protection for low lube oil pressure, high coolant temperature(alarm and shut down) (iv) Alternator protection with parameters like under voltage, over frequency, under frequency, over current and shut down), (v) cyclic cranking (vi) Auto/manual/start/stop (vii) Alternator trim adjustment from the front key pad (viii) Model specific calibration from the front key pad (ix) speed bias or raise/lower inputs (x) Remote monitoring capability through separate interface modules.
(xi) 6 configurable discrete outputs (xii) 2 configurable discrete inputs. (xiii) smooth transition to rated speed. (xiv) housed in NEMA 3R/ IP 53 non-metallic enclosure. (xv) shall operate in wide temp range (0-60 °C) & humidity up to 95 %. (xvi) Diesel engine shall confirm to IS 10001/ 10002 and alternator shall conform to IS 13364.
EOT CRANE
Design, supply, installation, testing and commissioning of Flame proof (FLP), electrically operated, overhead travelling (EOT) cranes of 5 Ton capacity suitable for operation inside/outside Magazine containing explosives, having UN Hazard Classification as 1.1 and having slight quantum of generation of explosive vapours/dust, as per gas group I, IIA & IIB as per IS:2148-2004, soft start and soft stop, , conforming to IS : 3177 (latest revision), suitable for operation on 415 Volts, 3 Phase, 4 wires, 50 HZ supply, Double girder type, with necessary steel supporting structures, with Hoisting, Cross Travel (CT), and Long Travel (LT) with separate variable voltage variable frequency (VVVF) drives of suitable capacities with separate flame proof enclosures for each drive, conforming to IP : 65 and
CIMFR of any make : ABB/Schneider / VACOM duly certified for all motion. The soundness of makes as approved and should be certified by CIMFR ( Central Institute of Mining and Fuel Research). Dhanbad or Govt approved body, with control panel, power and controlling cables, confirming to relevant ISs, controlled by pendent control which shall be movable type along the crane , with creep speed @10% (Ten percent) for main hoisting LT & CT motions, no auxiliary hoist, and facility for mechanical lowering only at very slow speed, in case of power failure when a container is hanging on hook, with provision of cover lock with crane hook, provisions so that, in case of power failure the crane should lock in its current position, and also including the followings: -
(vii) Controls: The crane shall be controlled by pendant. The main electrical components shall be housed in Flame proof (Minimum Ingress Protection IP: 65) enclosures, conveniently located for easy maintenance. Standard protection devices for overload protection and short circuit protection shall be provided. (viii) Gantry Rails: As per contractors own design shall be provided. (ix) Down Shop Leads (DSL): DSL with flexible cable system with suitable cable tray shall be provided. (x) Buffers: Buffers on end carriage shall be rubber type. (xi) Limit switch ; (a) Main Switch : Geared Rotary + Gravity (b) LT & CT : Lever Type For the followings :
(a) Five (5.0) tons capacity, Electric Operated Approximately 18000 mm span, Approximately 36000 mm longitudinal travel, Approximately 5250 mm hook height to be installed in PINAKA Store Building at Panagarh. NOTE : (i) Cost of I Gantry Girder and it fixing on RCC Bracket shall be included in the cost of crane. However, fixing arrangement for girder in RCC Bracket as shown on drawing shall be included in the cost of building. (ii) This same shall be installed in each Magzine bldg. Gantry rails shall be common for both the cranes.
ANUPAM JANA
CHHABINDRA KUMAR PRADHAN
KAKALI ENTERPRISE
Aalaya Engineering Project Private Limited
NARSINGH DEVELOPERS LLP
surendra infrastructure pvt ltd
BRAITHWAITE AND CO. LTD.
RSB Projects Limited
Hariom Projects Pvt Ltd
NITYA NAND AND SONS CONTRACTORS PVT LTD
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid