Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-Finance Offer lowest offline rate therefore Provisional order issued | |
| 2 | L2₹8.8 L+₹99,310 (12.7%)Rejected-Finance FLAT NO 81 BLOCK C INDUSTRIAL HOUSING ESTATE SHYAMNAGAR SHYAMNAGAR SHYAMNAGAR NORTH 24 PARGANAS WEST BENGAL 743127 | 24 PARAGANAS NORTH | WEST BENGAL | 743127 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹9.5 L+₹1.7 L (21.7%)Rejected-Finance | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
1 Sept 2021, 1:00 pmClosed
EE KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Construction of proposed 2 nos. basement G plus2 Building with provision of G plus 9 storied foundation for TERTIARY CARE CANCER CENTRE TCCC at College of Medicine Sagore Dutta Hospital Kamarhati Kolkata SITC of Fire Detection System Additional Work
2021_WBPWD_340891_1
WBPWD/EE/KNHED/ NIQ-82/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹16,000
9 Mar 2022
18 Aug 2021
3 Sept 2021
20 Aug 2021
1 Sept 2021
20 Aug 2021
Amount
SITC of Analog Addressable Intelligent multisensor/ Heat detector ( Suitable for installed existing Siemens make FACP ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Suitable for installed exsisitng FACP )(Only Siemens)
SITC of LED type Response Indicator (Suitable for installed exsisitng Siemens make FACP) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Suitable for installed exsisitng FACP )(Only Siemens)
SITC of Microprocessor based Intelligent, addressable expandable and fully networkable moduler type 6 loop expendable upto 10 loop fire alarm control panel (suitable for existing SIEMENS make device ) not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. a) The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards,
L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required. b) The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved Make:Only Siemens)
Supply and Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe(Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
Supply and Laying of 2 core 1.5 sqmm FRLS shilded copper copper Cable (Make.Finolex/ RR Kable/ Polycab) with 25 mm NB GI rigid conduit pipe (ISI mark) for underground.
Office Automation Systems
NRD Global
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .