Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Single₹8.7 LAccepted-Finance | Single | Accepted-Finance Eligible |
Tender Value
₹8.5 L
EMD Value
₹16,978
Closing Date
1 Jul 2020, 12:00 pmClosed
SR. CE (E) BSNL Mumbai
O/o SR. CE (E) A Wing Gr Flr Admin Bldg BSNL Mumbai - 54
Shifting and ITC of 400 KVA transformer from TE Hadapsar to TE Sangli and SITC of emergency panel and asso. works
2020_BSNL_563906_1
1300/CEEM/2020-21/NIT/07
Open Tender
Electrical Works
Item Rate
30 days
Mumbai
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO (F and A) BSNL
₹16,978
Yes
2 Jul 2020
9 Jun 2020
2 Jul 2020
9 Jun 2020
1 Jul 2020
9 Jun 2020
Shifting of 400 KVA 11/0.433 KV, Three phase 50 Hz oil immersed, aluminium wounded & naturally cooled, outdoor type distribution transformer from TE Hadpsar Pune to TE Sangli i/c Dismantling, loading & unloading at site as desired by Engineer-In-Charge etc. as required.
Installation testing & commissioning of above-mentioned distribution transformer on existing double pole structure etc. complete as required. ( MSEDCL testing charges etc paid at actual if any, against submission of paid receipt)
SITC of LT double door out door type distribution box made out of 16 swg M S sheet on existing DP Structure with following switch gears complete with interconnections by Copper bus bar of 30mmx 5mm, epoxy insulators, locking arrangement, ventilating louvers, earthing stud i/c powder coating etc complete as required made as per MSEDC Ltd requirement. (Approx size 800mm x 800mm x 250mm deep). a) 400 Amp 3 pole 36kA MCCB. Magnetic Thermal Release, 100% Icu (M/s. Legrand L&T / Siemens / ABB/MSEDCL approved/accepted make) -- 1 no. i/c interconnection with 35x5 mm copper busbar & s/f neutral link etc as reqd. b) 400 Amp 500 volts procelain cutout (one no, neutral link) -- 3 nos. Note: 1) The panel size mentioned is only indicative. If the size of the panel required at site is more more than indicated, the same shall be provided at site & nothing extra will be paid on account of increase/addition in panel size. 2) Nothing extra will be paid if the switchgears actually installed at site are of costlier or larger capacity.
Supplying & fixing of MS channel/angle/flats etc of variable sizes as per specification as required.
Supplying & Fixing 11KV pin insulators conforming to IS-731 / 1971 & IS 2486 (Part-II)/1989 on existing structure / pole etc. as required. (M/s JSI / BHEL / HTIF / Punjab Ceramic / W S Ind. / Allied Ceramic / India Potteries make/ any MSEDCL approved make
Supplying & fixing of hot dip galvanized hardware set (Weasel) confirming to per specification as required.
Supplying installing, testing and commissioning of 11 KV, 400 Amp. three phase, HT gang operated off load, tilting. Single Air Break isolator switch suitable for horizontal & vertical mounting confirming to IS 9921/1985 (Part I to IV) complete with arching horn, pad locking arrangement in ON/OFF positions & manual operating mechanism etc. complete as per specification attached. (Note: The insulators shall be from the approved list of MSEDCL ) (Make- Kiron / Pactil / Atlas make).
Supplying, installing, testing and commissioning of 11 KV H T outdoor, vertical / Horizontal mounting type Horn Gap Fuse (one set comprises 3 units) conforming to IS 9385 / 1980(Part II) & IS 2633 /1972 etc. complete as required. (Make- Kiron / Pactil / Atlas / or any MSEDCL approved make).
Supplying & fixing of 11 KV LA fixing channel below horn gap confirming to per specification as required.
Supplying, installing, testing and commissioning of 11 kV Gap less type distribution class Lightning Arrestor (one set comprises 3 units) conforming to ISS 3070 (Part III) & ISS 5621 etc. complete with holding clamp as required. (Make-Elpro / Lamco / or any MSEDCL approved make)
Providing H.T. earthing set with light class G.I pipe of overall length 1.910 meters & nominal bore dia shall be 25 mm, confirming to IS- 1239/1979 or its latest version complete with Charcoal, salt and all accessories i/c testing as per specification / drawing as required. (Note- Earthing set shall be provided as below, LA - 2 nos, Tr. Neutral-2 nos, Body earth for DP & Tr.- 2 nos & 1 each for x’mission line poles)
Supplying & Laying of 8 SWG G.I. wire including connection etc. as required.
Supplying G I Nut Bolts .
Providing & laying in position cement concrete of 1:3:6 grade (i.e. 1 cement, 3 coarse sand & 6 graded stone aggregate of 40 mm nominal size) i/c excavation for pole foundation etc. as directed
Supplying & Fixing G.I. Barbed wire of size 2.5 mm x 2.00 mm (Line wire & point wire) confirming to IS 278/1978 or its latest version type 10 WA as per specification as required.
Providing & fixing HT danger notice plate of 250mmx200mm made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red colour on front side as required.
Supply of following size of 1.1 KV grade, XLPE insulated, cores laid up, sheathed, galvanized single flat steel strip / wires, armoured & heavy duty PVC outer sheath aluminum conductor cable (ISI marked cable) i) 3 & 1/2 core 35 sq. mm
Ii) 3 & 1/2 core 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. i) Above 185 sq. mm and upto 400 sq. mm ( Deparment Supply)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. i) Upto 35 sq. mm (clamped with 1mm thick saddle)
ii) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
iii) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) ( Deparment Supply)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 35 sq. mm (32mm)
ii) 3½ X 95 sq. mm (45mm)
iii) 3½ X 400 sq. mm (82mm)
Supplying & fixing of M S Angle & clamp etc for DTC meter confirming to per specification as required.
Supplying and laying of A.C.S.R. weasel conductor conforming to IS-398 (Part –I & II) /1996 of overall dia. of 7.77 mm on the existing pole on insulators including binding, testing, commissioning etc. as per specification as required.
Supplying & fixing of 11 KV V- Cross Arm confirming to per specification as required.
Supplying & fixing of 11 KV Top Pin support confirming to per specification as required.
Supplying & Fixing 11 kV disc insulator (70 Kg) conforming to IS-731/1971 & IS-3188 along with tension hardware on existing structure / pole as required. (M/s JSI / BHEL / HTIF / Punjab Ceramic / W S Ind. / Allied Ceramic / India Potteries make / any MSEDCL approved make)
Supply of R.S.J pole of nominal sizes 100 mm X 116 mm of length 11 meters (23 Kg/meter=253 Kg)for mounting of HV accessories etc. complete as red.
Erection of R.S.J pole of nominal sizes00 mm X 116 mm of length 11 meters along with painting with 2 coats of primer red oxide and 2 coats of silver paint complete with cutting, drilling holes, bending & welding etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply & laying of 4 core 1.5 sq mm copper conductor armoured 1.1 KV grade cable on surface/ground etc as required. (ISI mark cable)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply & errection of AB Switch fixing channel of suitable size confirming to specification as required.
Supply & errection of Horn Gap fixing channel of suitable size confirming to specification as required.
Supply & errection of 400 KVA Transformer base fixing channel of suitable size confirming to specification as required.
Supply & errection of 400 KVA Transformer guide set of suitable size confirming to specification as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .