Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.3 L
EMD Value
₹6,540
Closing Date
29 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
PROVISION OF CHANGE SWITCH AND PANEL BOARD AND MISC ELECTRICAL WORKS AT DEPOT BN MEG CENTRE UNDER GE NORTH BANGALORE
2026_MES_792927_1
8357
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Bangalore
Class E Category b(i)
9 documents required · 9 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹6,540
Yes
8 Oct 2026
8 Oct 2026
5 Nov 2026
8 Oct 2026
29 Oct 2026
22 Oct 2026
8 Oct 2026 - 22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fabricate,install and testing factory made bus bar chamber, outdoor type, weather proof having both side openable hinged door shutters with locking arrangement, size of chamber 80cm x 60cm x 45cm made of 3 mm thick CRCA sheet, powder coated paint inside and outside, wleded with 4 Nos angle iron legs of size 40 x 40 x 6mm, 80cm long duly painted with two coats of black enamelled paint over a coat of red oxide primer and errected in PCC 1:3:6, type C2 foundation at suitable depth and having the following :- (a) 100A Change over switch -01 No (b) MCCB, 4 pole 415 volts, 25 kA, 100 Amps capacity with thermal load release relay-01 No (Incoming).
(c) MCCB 4pole 25 KA 63A 03 Nos (out going) (d) Starter suitable for 7.5 HP 2 nos
(e) Bus Bar chamber with copper strip with heat shrinkable insulating sleeve, size 30x5mm, 4 Nos of required length supported on FRP insulators, internal wiring for indicators with 10 Sqmm copper cable single core of required length.
(f) Indicator lamps with LED bulbs for R,Y,B with copper cable wiring - 01 Set.
(g) MCB TPN 16A with housing fecility 02 Nos
(h) MCB SPN 6Amps with housing fecility 2 Nos | 1 | EACH | 100 | ₹100 |
| 2 | Mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia. | 10 | RUNNING METRE | 100 | ₹1,000 |
| 3 | M&L for laying, jointing, testing cable XLPE insulated, armored and PVC sheathed LT 1100 volts grade and aluminum conductor confirming to IS 7098 laid in trenches/through pipe/floor/fixed wall etc complete all as specified and directed for size of cables 25 Sqmm 3.5 core stranded conductor | 40 | RUNNING METRE | 100 | ₹4,000 |
| 4 | "M&L for laying, jointing, testing cable XLPE insulated, armored and PVC sheathed LT 1100 volts grade and aluminum conductor confirming to IS 7098 laid in trenches/through pipe/floor/fixed wall etc complete all as specified and directed for size of cables 16 Sqmm 4 core stranded conductor | 30 | RUNNING METRE | 100 | ₹3,000 |
| 5 | Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor | 40 | RUNNING METRE | 100 | ₹4,000 |
| 6 | S&F outdoor type LED Post top lantern 40 watt with die cast aluminium , spigot,spun aluminium powder coated top cover, heat sink, opal PC diffuser and clear acrylic IP-65 protection, including taking down old unserviceable lantern.
MAKE :- HALONIX or equivalent makes of Bajaj and Havells. | 10 | EACH | 100 | ₹1,000 |
| 7 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth iron strip 25x4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. | 2 | EACH | 100 | ₹200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
8357Tender.pdf
Tender Documents • 0.94 MB
BOQ_889180.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .