Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.3 L+₹63,795 (3.25%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹20.5 L+₹85,320.20 (4.34%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹26.7 L+₹7.1 L (36.1%)Rejected-Finance 110 245 NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L4 | Rejected-Finance BEING L4 | |
| 5 | Rejected-Technical WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | - | Rejected-Technical DUE TO NOT HAVING APPROPRIATE CATEGORY I.E C (I) |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
21 Jul 2023, 6:00 pmClosed
GE (AF) UDHAMPUR
GE AF UDHAMPUR
REPAIR / MAINTENANCE OF CERTAIN MISC E/M EQUIPMENT SUCH AS SMOKE DETECTOR / FIRE ALARM SYSTEM / WINDOW / SPLIT AIR CONDITIONING / AVIATION LIGHT ALONGWITH CONNECTED E/M WORK AT 901 SU AIR FORCE STATION NATHATOP UNDER GE (AF) UDHAMPUR GE/AFU-35/23-24
2023_MES_607225_1
GE/AFU-35/2023-24
Open Tender
Civil Works
Item Rate
270 days
AF STN UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹44,000
Yes
1 Sept 2023
30 Jun 2023
24 Jul 2023
30 Jun 2023
21 Jul 2023
14 Jul 2023
Amount
Servicing of Fire Alarm control panel complying with adderssable type single loop panel /double loop of capacity from 99 detectors & modules upto 200 detector with UV/IR Detection capacity including the following technical specifications and all specified and directed by AGE E/M Note :- (a) Primary power supply : 220v +/- 10% AC, 50Hz (b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries ) (c) Battery charging voltage ; 27.5 +/- 1V (d) Battery caharging current : 500 mA (max) (e) Pragrammable relay contact : 3 Sets. (f) Relay Contact Rating : 2 Amps 30 V DC (g) Operating temp :- 100C to +550C (h) Humidity : 0 to 95% RH (i) Internal wiring complete two core (j) 1000 event history log (k) Built in battery Charger (l) Two level password protection (m) Contamination level alart for maintenance (n) Detection sensitivity adjustments (from panel) (o) Alarm verification feature
Servicing of Fire Alarm control panel complying with Conventional type panel /double loop of capacity from 99 detectors & modules upto 200 detector with UV/IR Detection capacity including the following technical specifications and all specified and directed by AGE E/M Note :- (a) Primary power supply : 220v +/- 10% AC, 50Hz (b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries ) (c) Battery charging voltage ; 27.5 +/- 1V (d) Battery caharging current : 500 mA (max) (e) Pragrammable relay contact : 3 Sets. (f) Relay Contact Rating : 2 Amps 30 V DC (g) Operating temp :- 100C to +550C (h) Humidity : 0 to 95% RH (i) Internal wiring complete two core (j) 1000 event history log (k) Built in battery Charger (l) Two level password protection (m) Contamination level alart for maintenance (n) Detection sensitivity adjustments (from panel) (o) Alarm verification feature
S&F in repair of Addressable manual call point resttable type fire alarm type panel the following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
S&F in repair of conventional fire alarm panel the following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
Supply and replacement of Smoke Detectors Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of Mother board (Addrassable type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 including taking down omplete all as specifeid and as directed.
Supply and replacement of Mother board (Conventional type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of Hooter Conventional/addressable type Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of manual call point Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 including taking down complete all as specifeid and as directed.
Servicing and cleaning of Smoke Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 as per existing and arrangement of ladder of suitable building height complete all as specifeid and as directed.
S&F in repair of Remote response indicators addressable typeincluding the following technical specifications and all specified and directed Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded copper fire serval cable conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including taking down complete all specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded fire serval cable copper conductor of size 1.5 sq mm ,6 core, 1100 Volts grade complete including taking down all specified and directed Engr-in-Charge.(Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
Supply and repair of Battery sealed accied as per existing size suitable for control panel 24 V DC (2 Nos of 12V, 7 SMF batteries )complete all as specified and as directed.
Maintanence and repair Remote response indicators conventional type including including replacement of unservisble spare parts and all specified and directed Engr-in-Charge.
M & L for Servicing and maintanence for Indoor and outdoor unit of split type Air conditioners 1.5/2.00 Ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, incl good cleaning carefully for out side area used soft cloth with coolin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, all as directed.
M & L for Disconnecting, cutting and taking out Evaporated Coil for indoor / Condensing coil for outdoor unit for 1.5/2.0 ton AC Invertor/Non invetor type find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge.Note :- The cost of item shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
M & L for Disconnecting, cutting and taking out unserviceable compressor inveter type for 1.5 Ton Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make : Highly/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
M & L for Disconnecting, cutting and taking out unserviceable compressor inverter type for 2 Ton Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make :Highly/ Voltas/Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
M & L for Disconnecting, cutting and taking out unserviceable compressor non Inverter type for 1.5 Ton/ 2.00 TON Spilt type AC and replacing with same new compressor including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge. Make :Highly /Bluestar/LLoyd/Carrier Note :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account.
M & L for in repair (Existing make & size ) Panellcontrol Board of Invrter type including remote and display of 1.5/ 2.0 Ton AC, all as specified and directed.
M & L for in repair (Existing make & size ) Panellcontrol Board of non Invrter type of 1.5/ 2.0Ton AC, all as specified and directed.
M & L for in repair (eixsiting same size ) Indoor unit blower motor for 1.5 Ton capacity AC, all as specified and directed.
M & L for in repair (eixsiting same size ) Indoor unit blower of fan and bushes for 1.5 Ton capacity AC, all as specified and directed.
M & L for in repair (eixsiting same size ) Indoor unit blower motor for 2.0 Ton capacity AC, all as specified and directed.
M & L for in repair Hot and cold reversivle valve with resistance (eixsiting same model & size ) for 1.5/2.0 Ton capacity AC, all as specified and directed.
M & L for in repair running capacitor 45 mfd + 3 mfd for 1.5 ton AC (combined unit), all as specified and directed by Engineer-in-Charge.
M & L for in repair running capacitor 50+4 mfd for 2.0 ton AC (combined unit), all as specified and directed by Engineer-in-Charge.
M & L for in repair starting capacitor 80 mfd - 100 mfd for 1.5/2.0 ton AC and deep freezer all as specified and directed by Engineer-in-Charge.
M & L for in repair route pipe (copper tube) of size 3/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
M & L for in repair route pipe (copper tube) of size 5/8" dia complete with insulation all as specified and directed by Engineer-in-Charge.
M & L for in repair route pipe (copper tube) of size 1/4" dia complete with insulation all as specified and directed by Engineer-in-Charge.
M & L for in repair route pipe (copper tube) of size 1/2" dia complete with insulation all as specified and directed by Engineer-in-Charge.
Supply and refilling of gas R-22 & 32 in 2 .0 /1.5 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
Supply and refilling of gas R-410a in 1.5 /2.0 Ton AC including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge.
M & L for in repair (eixsiting same model & size ) Copper filter for 2.0 ton split AC complete all as specifed and as directed
M & L for in repair (eixsiting same model & size ) Copper filter for 1.5 Ton split AC.complete all as specifed and as directed
Supply and replacing Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA.(Make : V- Guard model VWR 300 equivalent Micro tech) all as directed.
Supply and replacing Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.(Make : V- Guard model VWR 500 equivalent Micro tech) all as directed.
M & L in repair for taking out the voltage stabilizer of capacity up to 3 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed.
M & L in repair for taking out the voltage stabilizer of capacity 4 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed.
Supply and replacing (eixsiting same model & size ) control card of voltage stabilizer PCB sensor etc.all as specified and directed by Engineer-in-Charge.
Supply and replacing Ics and relays complete all as specified and directed by Engineer-in-Charge.
M & L in repair for taking out the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ.
Supply and in repair of compressor sealed unit including necessary brazing work as required.
Supply and in repair of Thermostate switch suitable for 280/310 Ltrs caapcity refrigerator.
Disconnecting and dismantling and transfortation of UPS from system and main supply and making alternate arrangement for smooth functioning of the system at radar room AF Nathatop to workshop for repair.
Opening the UPS UP TO 5 KVA and repairing the main control card by replacing, trickling ckt, charging ckt, integrated ckt, etc from the manufacture and testing as per manufactured design all as directed by user at site. Note:- All the spare parts are measured and paid seperately
Opening the UPS 6 to 10 KVA and repairing the main control card by replacing, trickling ckt, charging ckt, integrated ckt, etc from the manufacture and testing as per manufactured design all as directed by user at site. Note:- All the spare parts are measured and paid seperately
Replacement of resistance 1.5 OHM 20 Watt as per sample
Replacement of AC capacitor( 4300/UF/450 Volt) as per sample
Replacement of DC capacitor( 4300/UF/450 Volt) as per sample
Replacement of bridge block 3 phase HD 12/12 as per sample
Replacement of IGBT as per existing size
Replacement of ae per DC breaker existing size
Replacement of PCB Cards as per existing size
Replacement of Transformer existing size
Rerplacement of Cooling Fan as per existing size
Replacement of capacitor 2MFD 20 Watt as per sample
Reassembling the UPS after necessary repair and replacement and testing at site including labour and transportation complete at site.
M&L for replacementof existing unserviceable batteries of, 12 volts, 45 AH all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/Sukam/Microtek.
M&L for replacementof existing unserviceable batteries of, 12 volts, 26 AH all as specified and directed. Make: EXIDE /Amron/AMCO/Okaya/Sukam/Microtek.
Supply and Refilling of gas in the compressor of refrigerator of any make and capacity with R-134a gas/ carbon free gas.
M & L in repair for Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completion of job, all as directed. Note :- Spares required for repair work will be measured and paid for separately under respective item of BOQ.
Supply and in repair of compressor sealed unit including necessary brazing work as required. Make ; Voltas/ blue star/ carrier
Supply and in repair of blower motor for any cap/size of deep Freezer complete all as specified and as directed .
Supply and repair of thermal over load relay. Make :- Renutrol/Indfoss or equivalent as approved by GE.
M & L in repair for Stands for outdoor unit including drilling hole, nuts bolts , fastners etc complete all as required at site.
M&L in repair of MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 203 volt AC supply including taking down existing old US including assesories therein & disposing from site complete all as specified
M & L in repair for MCB DB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and directed by the Engineer-in-charge.
Supply and fixing in repair of MCB SP 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker current carrying capacity in the MCB DB complete with connection testing and commissioning of complete all as specified and as directed.
Supply and fixing in repair of MCB SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
M&L in repair of wiring for circuit 2 core 2.5 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit making connection with LED Building security Light/ tower light / fitting etc complete all as specified and as directed by enginer in charge .
Supply and fix in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of including necessary electric connection2.5 sqmm 3 core pvc insulated PVC copper cable as per manufacture's requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.Cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips
Supply and fixed rolled mild steel Joist channel,angle or tee sections fixed independently ,with out connecting plates etc conforming to FE 410-W Quality -A alonwith welding/ riveting of specifeid shape and necessary civil /PCC wORK(ie 30cm below ground level and 40 cm above level )etc.complete all as specified and as directd.
Taking down/ dismentling the old / UNSV duct of central AC plant and M&L to assembly/ eroction of GI sheet with C&SS , rectangular / boxed, incls all accessories such as corner, cleat , carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 26 gauge . In Laid Wool installation not less than 30 mmthick over all surrounding the duct and 15 mm thick cement randering work over / around the complete duct with chicken wire mess of suitable size all is specified and directed. Note: The inner size of duct is not less than existing.
M/S M P Construction Co
shivom builders
SHARMA SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .