Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹44.8 L+₹7.8 L (21.0%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
8 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEOLALI
GE DEOLALI, 422401
PROVN OF OPEN SHED NEAR BLDG NO 194 AND CERTAIN MINORS REVENUE WORKS OF HQ SOA UNDER THE AOR OF GE DEOLALI
2022_MES_551568_1
8142/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEOLALI
class D cat a i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹96,400
Yes
15 Nov 2022
13 Sept 2022
10 Oct 2022
20 Sept 2022
8 Oct 2022
26 Sept 2022
60 days
Amount
Surface Excavation nexc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc. 1.5m in depth for foundation, etc. or for shaft, wells and cesspits in soft/loose soil all as directed.
Ditto all as per Item No 2 above but depth exc 1.50m and n.exc 3.0m in hard dense soil all as specified and directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed.
Removing excavated material upto a distance n, exc 50m and depositing where directed at a level n exc 1.5m from the base.
Removing excavated material upto a distance exc. 250 m but n exc. 500 m & depositing where directed at a level not exceeding 1.5m above the starting point.
M&L for hardcore of broken stone or boulders of guage n exc 63 mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as directed.
M&L for PCC 1:4:8 type D2 using 40mm grade stone aggregate as in foundation concrete etc complete all as specified and directed.
M&L for RCC M-25 (Design Mix in) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and as directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
Material and labour forRCC M-25 (Design Mix in) (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L for RCC M-25 (Design Mix) slab supported as on wall beam and columns in floor roofs, loading balconies, conopees and in shelves using 20 mm graded stone aggregate using 20 mm aggregate
M&L for providing RCC chajja (Design Mix) using 20mm graded stone aggregate in slab supported on wall beam, column etc
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
Material and labour for formwork to sides of concrete beams, and similar work; vertical or to batter for rough finished surface of concrete, flat complete all as specified and as directed.
Form work to chajja trough and similar item including edges in falt for rough finished surface of concrete
Form work to soffit of suspended slab such as a roof slab not exceed 200mm thick for fair finish surface of concrete
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
Ditto- above item no 20 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
Supply and fix Mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases,splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc. complete all as speciified and drected.
M&L for Plates (plain or chequered)channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe 410W (gde-E-250) quality A,
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long
S&F Pre- painted galvalume aluminum zinc coating GI based mangalore pattern corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws as specified and directed.
M&L for fly ash brick work with old size sub class 'B' bricks straight or curved on plan exc. 6m mean radius and built in CM 1:6 etc complete all as directed.
M&L for fly ash brick sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls and built in CM 1:4 etc complete all as specified and directed.
M&L for 5mm thick ceiling plaster on concrete surfaces in CM 1:3 finished even and smooth with a thin layer of sagol.
M&L for 10mm thick Plastering in cm 1:6 on other than fair faces of brick wall or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces of walls sand faced sponge faced finish etc complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying one coat of primer over a coat of birla white cement putty,sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper etc complete all as directed.
M&L for preparation of new surfaces and applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Emulsion : Asian (APEX SUPREMA) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) or equivalent as approved by GE.
M&L for preparation of newly plastered surfaces & applying two coat of cement base paint over one coat primer all as specified.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash etc complete all as directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash etc complete all as directed.
M & L for preparation of new steel surfaces exc 10 cm in width/girth and applying two coats of synthethic enamel paint over a coat of primer red oxide zinc chrome etc complete all as directed.
M&L for Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) 75mm thick as in subbase complete all as directed.
M&L for 100 mm thick cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in paving.
M&L for Cement concrete type D- 2,1:4:8 100 mm thick (20mm graded stone aggregate) as in sub- base to floors.
M & L for 25mm thick Cement concrete type B-0, 1:2:4 Finishing cement concrete surface even and smooth without using extra cement (using 12.5mm graded stone aggregate) as floor all as per direc ted
M&L PCC 1:2:4 type B1(using 20mm graded stone aggregate), 40mm thick laid in slope of 1:20 and alternate bays incl finished even and smooth without using extra cement and joints in the plinth protection etc complete all as specified and directed.
M&L for Providing, cement concrete type B1 1:2:4 (using (20mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses,parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and paving n exc. 15cm thickness (below or above ground level) complete all as specified and directed
M & L for 15 mm bore of tube medium grade Galvanised steel water tubing with all fittings and fixed complete to walls, or laid in floor etc complete all as specified and as directed.
All as per item No 48 above but 20mm bore pipe all as specified and as directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia Ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed etc complete all as directed.
S&F 15mm bore bib taps, chromium plated cast copper alloy quarter turn long body screwed down, screwed for iron pipe etc complete all as directed
S&F 15mm bore stop valves, chromium plated cast copper alloy quarter turn long body screwed down, screwed for iron pipe with long shank and cup (concealed type) etc complete all as directed
S&F 20mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe etc complete all as directed.
S&F fancy type Brass chromium plated 600mm long Towel Rod fixed with screws and wooden/plastic cleats etc complete all as directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as directed.
All as per item no 56 above but 110mm dia complete all as specified and directed.
S&F glazed earthen ware vitreous china wash basin white coloured flat back size 600x480mm, outlet of 32mm bore HDPE outlet pipe with necessary fittings, 32mm bore brass CP waste couplings etc complete all as directed.
S&F PVC connection 15mm size with PTMT nuts of length 600 mm.
S&F anodised/powder coated aluminum alloy interlocking snap grid 600mm x 600mm consists of Min Tee runners of size 38mm x 25mm x 1.5mm and cross Tee of size 25mm x 25mm x 1.5mm, spaced between the main Tee at 600mm centre to centre to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 2mm fixed to wall perimetrs at 450mm centres and shall confirm to IS 733, IS 1285 with and including hangers of 6 mm dia. G.I. (upto 1200mm length and 1200mm centres) adjusting level fixed to roof steel members by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long etc complete all as specified and directed.
M & L for 4mm thick designer non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified and direced.
S&F 80 mm thickness M-40 Grade factory made rubber moulded machine pressed precast conctete interlocking paver block in grey cement with pigment glossy fininsh and of approved size and shape and size confirming to IS 15658-2006 etc complete all as directed.
M&L for 30mm thick sand bedding layer for concrete paver tiles laid to true line, level watered and mechanically compacted etc complete all as directed.
Taking up or down 25mm bore of pipe GI steel tubing and connections, including cleaning for refixing or removal outside MD land etc complete all as directed.
Taking up or down 20mm bore of pipe GI steel tubing and connections, including cleaning for refixing or removal outside MD land etc complete all as directed.
Refixing old 25mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Refixing old 20 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Disconnecting existing tanks exc 500 and n. exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. if required reconnecting and re-fixing in position.
S&F in repairs 25 mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe etc complete all as directed.
Removing existing water proofing treatment to complete any descrption,thickness and in any position including removal of rubbish of the premises etc complete all as directed.
M & L for cleaning the newly plastered surfaces of concrete ( roof etc) with wire brushes and applying water proofing treatment as under :- i) Applying one coat of bituminous primer @ 0.25 Kg/Sqm ii) Providing and laying 3 mm thick APP modified water proofing membrane weighing not less than 3.0 Kg / Sqm reinforced with non woven polyester mat weighing not less than 150 gm/Sqm all as specified procured from any one of the approved manufacturer's instructions iii) Apply two coat of aluminium paint @ 0.15 Kg/Sqm over membrane over roof surfaces complete all as per manufacturer's instructions and as directed .
M&L for cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) 40 mm thick mixed with water proofing compound as specified in manufacturer as in roof to achieve slope on existing roof surface all as directed.
M & L for Forming Contraction Dummy joints (65mm deep x 10mm wide) ,filled with sealing compoundGrade B
M & L for Non - skid Glossy finish joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) laid in floors area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. with and including 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as directed.
M & L for glazed ceramic coloured joint free tiles in vertical surface 450X 350X 7mm thick with and including 10mm thick CM 1:4 backing coat, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as directed.
M&L for 20mm thick black granite (Table rubbed and polished) as in jambs, steps, pillars, window cills, platforms and the like with and including 15mm bedding in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match the colour of granite etc complete all as directed.
Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet single side pre lam PVC sheet used instead of plain colour reinforced with MS square tube, edges will be painted to match with prelam sheet. Make-Accucel,/rajshree
S&F factory made solid PVC profiled panel door shutter 28 mm thick with integral skin as frame & 3 mm thick high pressure compact laminated on both side of approved color as infill, with C type GI o 40x20x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing.Make-Accucel,/rajshree
S & F Extruded aluminium alloy handles fabricated type anodised 150 mm size.
S & F aluminium anodised, barrel tower bolt of extruded section, 150mm long.
S & F butt hinges,extruded aluminium alloy with galvenised mild steel hinge pin ,anodised and fixed,type B-21 100mm.
S&F angle stope valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends including fixed in repairs all as specified.
S&F 75mm dia CP grating doom fixed complete all as specified and directed by Engr-in-charge
S & F PVC ( SWR) bends/door bend /tee/door tee 110mm dia including dismantling of old PVC(SWR) pipe complete all as specified and directed.
S&F vitreous china urinal half stall type white (excluding flushing cistern, flush pipe and waste pipe) with and including brass chromium plated fancy type flush pin and 40mm bore dia brass chromum plated dome type waste coupling etc complete all as specified and directed.
S & F PVC valve less, syphonic action type, flushing cistern 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle, including brackets etc complete all as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F viterous china wash down water closet(pedestal pattern) white coloured with and including plastic water closed seat, white, closed pattern with recessed bottom, and cover and mild steel chromium plated hinging device etc complete all as directed.
S&F glass shelf of size 600x125mm with brass chromiun plated fancy brackets and railing fixed with screws and wooden/plastic cleats etc complete all as directed.
S&F fancy type Brass chromium plated 600mm long Towel Rod fixed with screws and wooden/plastic cleats etc complete all as directed.
S&F 15mm size fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as directed.
S&F 15mm size fancy type Bib taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as directed.
Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size including provision of PVC modular type terminal boxes of suitable module made with PVC sheet and suitable for fixing modular type switches, Cover plate of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for following:-
One light point controlled by one switch.
One fan/ Exhaust fan point controlled by one switch
One 5 pin socket outlet 5 Amps on the same board.
One 5 pin socket outlet. 5 Amps on the independent. board
All as per item No- 96 above but One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire.
Supply and fix following accessories in replacement of existing all as specified and as directed:-
Ceiling rose, 3 terminal, PVC / Polycarbonate insulated body
Modular type switch, 1 way, 6 Amps, 1 module
Modular type socket, 2 & 3 pin combined, 6 Amps, 2 module
Modular type switch, 1 way, 16 Amps, 1 module
Modular type socket, 3 pin, 06 / 16 Amps combined, 2 module
Electronic step regulator (Modular type) (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep 100 watts
Supply and fixing LED tube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S & F in replacement of lamp Holder angle/batten type with LED Lamp (B22 Base) 10 Watts complete all as specified and directed.
Supply and Fix in replacement of Street Light fitting LED 35 W madeup of pressure diecast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection
Supply and fix sheet metal enclosure double door 8 way DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed.
Supply and fix sheet metal enclosure double door 4 way DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed.
S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed.
S&F MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, including dismantling of old fan and depositing E/m store. Complete all as specified
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S&F ceiling mounted 2x2 LED luminaire Pluto neo panel with glare free soft light 34 Watt complete pre-wired all as specified and directed.
Suuply and fix in repairs powerline vertical DB 8 way IP-43 metal door Suitable for Four Pole MCCB up to 125Amp 415 V 16 KA as incoming in double door DBs complete all as specified and as directed.
Supply and fix in repairs MCCB triple pole and neutral 125Amp 415V 36 KA Thermal release, complete all as specified and as directed.
Supply and fix in repairs MCB triple pole and neutral 415 V 63 Amps complete all as specified and directed. .Make : L&TBB4060B
M & L for sub main wiring with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete all as specified and directed in conduits/ PVC capping- casing. Note :-(i) Two run of copper cable and one run of earth wire shall be measured as one length. (ii)Rate of casing-capping/ conduit deemed to be included in rate quoted.
M & L for sub main wiring with 4 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 4 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete all as specified and directed in conduits/ PVC capping- casing. Note :-(i) Three run of copper cable and one run of earth wire shall be measured as one length. (ii)Rate of casing-capping/ conduit deemed to be included in rate quoted.
Supply and lay cable XLPE insulated Heavy duty screanedPVC bedded, galvanized steelstrip or wire armoured, electric power cable 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core.
Supply and lay cable XLPE insulated Heavy duty screanedPVC bedded, galvanized steelstrip or wire armoured, electric power cable 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core.
Excavation in trenches for laying cable/poles etc n.exc in 1.5 mtr deep including getting out in any type of soil.
Supply & lay common burnt Sub Class B Brick laid over sand caushioning for mechanical protection
M&L for Sand cushioning to under ground cable with layer of sand 8 cm deep before laying and after laying 13 Cm Above the cabe. Note Punned thickness 18 CM wii be measured.
S & F Steel pipe glavanized grade of 40 mm Dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers complete ass as specifed.
M&L for GI tubing 25 mm dia Medium grade with all fittings laid in trenches or fixing in wall, all as specified an directed.
Cutting , screwing, threding and fixing GI tubing for alteration or addition size of 25 mm dia GI tubing
S&F for Gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed suitable for 25 mm dia GI tubing all as specified
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR. (NOTE:-cost of mounting stand for outer unit is deemed to be included in rate quoted)
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps capacity
Note: Amount of sch of credit of Rs.7365/-will be deducted from total amount of BOQ.
J Sams Contructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .