SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR / MAINT OF SECURITY , STREET LIGHTS AND ALLIED WORKS AT AF STN SARSAWA
2020_MES_343724_1
8120/SAR-10/E8
Open Tender
Civil Works
Item Rate
183 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF)SARSAWA
₹97,500
Yes
10 Jun 2020
9 May 2020
5 Jun 2020
9 May 2020
3 Jun 2020
19 May 2020
9 May 2020 - 19 May 2020
Amount
Repair and maintenance of street light/security lights/flood lights installed at various locations of domestic area by removing the lights from pole/bldg or any other place where ever is installed, throughly checking, cleaning of the glass/ acrylic covers and make them serviceable by removing/repair of unsv parts and refixing the same at original place complete all as specified and directed. Note :- (i) Replacement of the parts shall be measured and paid seperately. (ii) If repaire light become unsv before 01 year the same shall be repaired by the contractor free of cost. No extra payment shall be made.
Supply & fixing of LED aviation light yellow painted die cast aluminium alloyl housing with five parellel circuits max 12 watt consumption with all accessories with and including one LED lamp 12 watt after taking out light fittings as existing at site complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 45 to 60W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 70 to 90W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 150W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED street light fittings 200W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply and fixing 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as specified and as directed.
Supply and fixing 60 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as specified and as directed.
Supply and fixing 120 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy supported with LM-79/80, cast aluminium alloy housing IP 66 protection, input voltage range 120-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed. Notes for Ser No 02 to 09: (i) Minimum one light fitting from each & every lot of supply be tested on above parameters from NABL accredited and Govt. approved independent lab. (ii) GE may also order for carrying out testing for certain more light fitting if he requires essential.
Supply and fixing 150 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy supported with LM-79/80, cast aluminium alloy housing IP 66 protection, input voltage range 120-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Supply and fixing 200 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy supported with LM-79/80, cast aluminium alloy housing IP 66 protection, input voltage range 120-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Taking down 250/400 watts flood lights mercury/sodium vapour light fittings, mounted on pole, post top lantern on high mast poles brackets etc all as specified and directed. Note : Existing LED lights shall not be repalced / shall not be taken down complete all as specified and as directed.
Supply and fixing 250 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy supported with LM-79/80, cast aluminium alloy housing IP 66 protection, input voltage range 120-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm all as specified and directed. Note :- In account of above item complete all as specified and as directed.
S&F in replacement multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.5 sqmm 3 core, length not less than 1.5m each drawing through tubular pole and GI brackets etc upto LED light and making connections and testing for functioning of light fittings complete all as specified and as directed.
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for taking out/laying of U/G HT/LT cable and getting out the excavated soil including triming the sides
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed Engr-in-Charge.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for Sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggregate for coping of poles and stay assembly including use and waste of necessary from work including demolition of existing PCC complete all as specified and as directed.
S & F in replacement GI pipe 50 mm bore light grade for protection of cable /on wall/underground/road/on pole/flour all as specified & directed.
S & F in replacement GI pipe 40 mm bore light grade for protection of cable /on wall/underground/road/on pole/flour all as specified & directed.
Supplying, laying, jointing & testing of LT cables XLPE insulated, PVC sheathed aluminium conductors multistranded armoured heavy duty 1100 volt grade cross sectional area 06 sqmm 2 core laid in trenches/ducts/along poles/through pipe under road complete all as specified and as directed.
All as per item No 6 above but size 10 sq mm 2 core complete all as specified and as directed.
All as per item No 6 above but size 16 sq mm 4 core complete all as specified and as directed.
All as per item No 6 above but size 25 sq mm 4 core complete all as specified and as directed.
Supply and laying double walled corrugated HDPE duct pipe of 40 mm outer dia confirming to IS 14930 Pt II with antirodent and non flame propergating properties of approved colour complete with fitting for cable protection complete all as specified and as directed.
S&F in replacement Non metallic Junction box made out of PVC size not less than 28 cm x17cmx10cm hinged with lockable arrangement including aluminium bus bar TPN capacity 200 Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
S&F in replacement Non metallic Junction box made out of PVC size not less than 18 cm x10cmx8cm hinged with lockable arrangement including aluminium bus bar SPN capacity 100Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply & fix Decorative LED Post Top Lantern light fitting with max. system wattage 36/40 watt and system lumen output not less than 100 lumen per watt, total system lumens not less than 3600 lumens, PF not less than 0.95, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, surge protection 5 Kv,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution all as specified and directed by Engr-in-charge. Notes:- 1. The material of any MAKE or manufacturer of the luminaire mentioned above, whose products do not comply with the required specifications and quality, will not be accepted and contractor or the manufacturer will have no claim on account of rejection of materials on this ground. 2. Name of the MAKE of the luminaire should be embossed on the luminaire fittings. 3. The contractor shall submit test report from manufacturer of the LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item to comply with minimum requirements mentioned therein. 4. The contractor shall also submit LM-79 & LM-80 test report from any valid NABL accreditation laboratory.
Supply, installation , testing of battery 85 AH 12 Volt, (tubular acid battery with 60 months warranty) type of battery - Lead acidic tubular Normal voltage 12 Volt, Capacity @C10-85AH used in Solar Street lights including taking down unserviceable battery all as specified and directed
Supply, installation, testing of battery100/105 AH 12 Volt, (tubular acid battery with 60 months warranty) type of battery - Lead acidic tubular Normal voltage 12 Volt, Capacity @C10-100/105 AH used in Solar Street lights including taking down unserviceable battery all as specified and directed
S&F in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed.ranty all as specified and directed.
Repair/rewinding of high mast motor 0.75HP by dismantling of mast assembly from pole with manually & checking of all parts & control wiring from control gear box to fitting at site. Lifting of mast assembly with help of motor after proper rewinding/repair/greasing of motor complete all as specified and directed.
S&F LED driver suitable for 10 watt led garden light including taking out old driver with LED complete with all as specified and directed. Driver should be same make as installed as before in Led light fitting.
Supply and fixing in replacement 2.5 inch dia 5 Watt LED down lighter all as specified and directed.
Supply and fixing in replacement water proof 3 Watt LED fountain light of different colour all as specified and directed.
Supply and fixing in replacement 6 Watt LED spike light of different colour all as specified and directed.
Supply and fixing in replacement 6 Watt LED bush light all as specified and directed.
Supply and fixing in replacement 30 Watt LED strip light all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.200mm wall thickness HT tape with adhesive of good quality all as specified and directed.
Supply and fixing thermal magnetic release 63 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
Supply and fixing thermal magnetic release 100 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
Supply and fixing thermal magnetic release 125 Amps 4 Pole MCCB Breaking capacity Icu 25KA all as specified and directed.
Supply and fixing thermal magnetic release 250 Amps 4 Pole MCCB Breaking capacity Icu 36 KA all as specified and directed.
Supply and fixing thermal magnetic release 400 Amps 4 Pole MCCB Breaking capacity Icu 50 KA all as specified and directed.
S & F in replacement Timer Panel, installation, commissioning and testing Polycarbonate CPRI approved OEM made main panel board shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1. The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 Degree C in accordance with 60695-2-11 flame retardant and self-extinguishing. Make- L&T/Hensel/Schneider/Siemens. Incl for comprising the following items :- (a) MCCB 100 A 25 KA 4 pole - 01 No Make : Legrand/Schneider/Siemens, (b) MCB SPN, 5-32 Amp- 01 No,Make : Legrand/Schneider/Siemens, (c) Power contactor ML-3 3 pole- 01 No . Make : Legrand/Schneider/Siemens, (d) Timer switch -01 No. Legrand/Schneider/Siemens, (e) By pass arrangement for testing/repairing the lights
RAJAN TRADERS
Raman Electric Trading Co
NAQLI LAL SHARMA AND ARUN SHARMA
AK Construction Co
VIJAY ENTERPRISES
SHRI RAM ENTERPRISES
Laxmi Builders
RAMAPATI ENGINEERING SERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .