| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | ₹36.1 L Quoted ₹37.6 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹37.9 L+₹28,712 (0.76%)Rejected-Finance | ₹37.9 L+₹28,712 (0.76%) | L2 | Rejected-Finance High |
| 3 | L3₹40.2 L+₹2.6 L (6.83%)Rejected-Finance | ₹40.2 L+₹2.6 L (6.83%) | L3 | Rejected-Finance High |
| 4 | L4₹40.3 L+₹2.7 L (7.09%)Rejected-Finance | ₹40.3 L+₹2.7 L (7.09%) | L4 | Rejected-Finance High |
| 5 | L5₹40.6 L+₹3.0 L (7.85%)Rejected-Finance | ₹40.6 L+₹3.0 L (7.85%) | L5 | Rejected-Finance High |
Tender Value
₹39.6 L
EMD Value
₹79,200
Closing Date
28 Aug 2021, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Spl repairs to PBOR Md accn bldg No P-350/1 to P-350/4 Inf Bde Sig Coy, certain B/R and E/M works in ORs Md accn block No P-13 (1 to 8) of MH at Tibri Mil Stn under GE Gurdaspur.
2021_MES_461115_1
GE GSR-27/2021-2022
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹79,200
17 Nov 2021
19 Jul 2021
30 Aug 2021
19 Jul 2021
28 Aug 2021
3 Aug 2021
Amount
Dismantling of roof brick tiles fixed in cement mortar in single layer.
Demolition mud phuska in roofs any thickness including plastering and leeping complete all as specified and directed.
M&L 40mm thick cement concrete type B-1 1:2:4 using 20mm graded stone aggregate with WPC @ 3% by weight of cement over cement slury 3 kg of cement per sqm finished even and smooth without using extra cement complete all as specifieda and directed.( WPC shall pe paid separately)
M&L for 40 mm thick brick tiles laid over 15 mm thick plaster in cement mortar 1:6 and jointed, grouted flush in cement mortar 1:3 mixed 5% of crude of by weight of cement on roof padding flush pointing in CM 1:3 complete all as specified and directed
All as per item No 05 but except tiles.
Providing cement concrete type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or cmamfered on edges, water trought and the like including weathering slightly rounded and threating as directed complete.
M&L for removing existing poinintg & flush pointing to bricks laid flat or brick tiles in pavings and pointing with CM (1:3) with crude oil 5% wt of cement complete all as specified and directed.
Roughing the surface of old concrete floor picking sweeping clean and washing down with water to remove dust/mud etc and brushing neat cement slurry @ 3kg/Sqm.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone agg) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 using 12.50mm graded stone aggregate as in roof padding averaging thickness of 50 mm complete all as specified.
M&L for 10 mm thick cement plaster in CM (1:4) using WPC on RCC roof slab including cleaning of existing surface complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
Demolition of cement concrete above ground floor and in any position.
Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed
S&F minimum 3 mm thick APP film based polymeric membrane minimum weighing 3 Kg/Sqm reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm ) laid on primed surfce by forced application over entire roof area with over lapping 100 mm to either sides and sealed in after cleaning down the surface and applying bituminous 85/25 @ 1.20 Kg/Sqm complte all as specified and directed. Note: Bitumen primer shall be paid separetly
M&L for rendering 15 mm thick in sunken portion fair faces of brick work or concrete surfaces on walls in CM 1:4 with water proofing compound, finishing even and smooth without using extra cement complete all as specified and directed Note: WPC shall be paid seprately.
Supply only integral water proofing compound.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in sunken portion complete all as specified and directed
M&L for PCC 1:5:10 type E2 using 40 mm stone agg filling fdn and mass cove in sunken floor complete all as specified and directed.
M&L 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in sub base for receiving the floor finishes complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n.exc 15 cm thickness (below or above ground level) and disposing the rubbish to a distance exc 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate as in floor Finishing without using extra cement, fair and even.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 20mm graded stone aggregate as in plinth protection Finishing fair and even.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement morter 1:4 , all as specified and directed.
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed
M&L 15mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and smooth without using extra cement and applying two coats of oil bound distemper over a coat of primer and not less than 1mm thick putty on plastered surfaces including taking down complete all as specified and directed.
M&L 15mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and smooth without using extra cement and applying three coats of white wash on wall plastered surfaces including taking down complete all as specified and directed.
M&L 10mm thick cement plastering on ceiling in CM 1:3 and applying three coats of white wash plastered surfaces including taking down complete all as specified and directed.
M&L 15mm thick cement plastering on fair faces in cm 1:4 on brick or concrete surfaces fair finished the surfaces even and smooth without using extra cement but with using water proofing compound including taking down complete all as spc upto height 12 mtr. Note : WPC shall be measured and paid separately.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extra cement complete all as specified and directed
Material and Labour for repairing of RCC projections, chajjas, roofs, facia etc. by necessary preparations i.e. scrapping, cutting, chiseling, dusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1 : 2 : 4) using 12.5mm graded crushed stone aggregate and reinforced with 10mm TMT bars with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches area n.exc 5 Sqm each and thickness of RCC member exc 50mm including applying two coats of Finishes to match with the existing surfaces in at any height complete all as specified. Note: - Cost of formwork and welded mesh, bldg ht upto 12 mtr, shall be deemed to be included in unit rate quoted by the Contractor.
M&L for repairs to RCC chajja, facia, bottom of chajja & by taking down cement plaster/detori old cement concrete, filling cement concrete 1:2:4 type B-0 & 10 mm thick plaster in CM 1:3 finished even and smooth without using extra cement.
M&L for Prepration of newly plastered surface and applying three coat of white wash as on ceiling.
M&L for preparation of old decorated surfaces plastered or un plastered of ceilng and applying two coat of white wash on ceiling inc complete removal of existing treatment complete all as specified and directed.
M&L for complete removing of existing treatment and applying one coats of water emulsion paint (Apex) of wall over a coat of 1mm thick wall putty over one coat of primer on wall complete all as specified and directed.
M&L for one coat of white wash on old treated ceiling surfaces.
M&L for complete removing of existing treatment and applying not less than 1mm thick putty and two coats of oil bound distemper over one coat of primer on wall complete all as specified and directed.
M&L for preparation of old decorated surfaces plastered or un plastered of walls and applying two coat of oil bound distemper on wall incl 1mm thick wall putty. complete removal of existing treatment complete all as specified and directed
M&L for preparation of new surface and applying two coats of oil bound distemper on walls over incl. 1mm thick walll putty complete all as specified and directed
M&L for complete removal of existing treatment anf finishing wall with Acrylic smooth exterior paint of reqd shade: New work (two or more coat applied @ 1.67 ltr/10sqm over and including priming coat of exterior primer applied @ 3.20 kg/10 aqm) all as spcd and directed.
M&L for prepration of newly plastered surfaces of wall and finishing wall with Acrylic smooth exterior paint of reqd shade: New work (two or more coat applied @ 1.67 ltr/10sqm over and including priming coat of exterior primer applied @ 3.20 kg/10 aqm) all as specified and directed.
M&L for prepration of two coats of synthetic enamel painting over one coat of primer on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of surfaces
M&L for prepration of two coats of synthetic enamel painting over one coat of primer on wooden surfaces of any description over 10 cm in width or girth not otherwise described including prepration of surfaces.
M&L for preparation of old painted wooden surface exc 10cm width or girth and applying one coat of synthetic enamel paint over one coat of primer complete all as specified and directed.
Taking down chowkats with shutter n.exc 1.50 Sqm each (without taking off shutter for the chowkats) and removing to store complete all as specified and directed.
Taking down chowkats with shutter exc 1.50 Sqm and not exceeding 4.00SQM.each (without taking off shutter for the chowkats) and removing to store complete all as specified and directed.
Taking down shutter of any description exc 1.00 Sqm but n.exc 2.00 Sqm each for resecuring or easing and refixing in the same opening complete all as specified and directed.
Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and directed
S&F pressed steel frames 1.25mm thick for door size of frame 125 X 60mm with single or double rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:2:4 type B0 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and complete all as specified and directed.
S&F pressed steel frames 1.25mm thick for door size of frame 105 X 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:2:4 type B0 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and two coats of synthetic enamel paint to outer surface with red oxide primer after prepration of surfaces complete all as specified and directed.
S&F 30mm thick factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to e fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, complete all as specified and directed.
S&F 32 mm thick both side laminated factory made flush shutters, solid core construction, with block board core and decorative face panels as decided by Engr-in-charge, on both sides complete all as specified and directed
S&F glazed and skeleton shutters 35mm thick of 2nd class hard wood open rebated and prepared to receive gauge & glass etc with edge of sash bar and number edges of framing plain chamfered beads for securing glass etc size of number of shutters as spd SSR Part-I & section 8 clause 8.23 & (b) complete all as specified and directed.
S&F 32mm thick flush shutter both side laminated , veenered face or as decided by GE complete all as spcd and directed.
S&F MS framed work as in door or gates of angle or other section with gusset plates,rail, braces,etc and similar work incl primer conform-ing to Fe 410-0 or Fe 250-0 complete.
S & F in repair 25mm prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F in repair 18/19 prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
M&L in repair for Block Boards, 18/19mm thick, grade 1 quality , exterior grade, commercial type, fixed with screws to timber frame work incl dismantling of old wooden work .Make: Green ply, Anchor or equivalent
Providing cement concrete type B1 1:2:4 (20 mm graded aggregate) in hold fast for doors all as specified and directed .
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks complete all as specified and directed.
S&F Aluminium anodized barel tower bolt of extruded section 150mm long ISI marked complete all as specified and directed.
S&F aluminium alloyed handle fabricated type anodized of size 150 mm long complete all as specified and directed.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt 200mm long ISI marked complete all as specified and directed.
S&F Mild steel sliding door bolts 300mm long stove enameled black with bolt not less than 12mm dia with and including a minimum of 6 bolt and nut complete
S&F in repairs 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate sections complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm.
S&F mild steel pressed handles, oval type, stove enamelled black size 150 mm long complete all as specified and directed.
S&F 75mm size hasp and staple safety type aluminium anodised brass with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and directed.
S&F 100mm long Hasp and staple , safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F 300mm, mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed. Note : Repair required on steel door frame, welding to be carried out or necessary alternative arrangements to be done.
Supply & fixing in repairs continuous (Piano) Hinges, MS bright finish or electro galavanised complete all as specified and as directed. Wdth of flaps (when open) 40mm.
Supply & fixing only butt Hinges, 100mm size, medium weight, stainless steel complete all as specified and directed
S&F including taking down steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mmX25mm single rebated comprises glazed shutter including guard bar ERW sec 50mmX20mm and 1mm thick with two openable leaf consisting two nos sash bar of T-section 20mmX3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 including following fitting welded to frame shutter:- (i) Hold fast,150mm long of 12mmX3mm made to shape-04 Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per window (iii) MS Tower bolt 150mm long-02 Nos per window (iv) Z sec 20mmX25mm,100mm long stopper -01 Nos per window (v) Cleat 55mm long of hollow square 15mmX12mm-02Nos per leaf (vi) Fabrication & fixing arrangements as Drg No CEJZ/TD-1020/06 (vii) M S guard bar 12mm square bars @120mm C/C fixed horizontlly.
S&F MS box type window/ventilator fixed type with glazing bar without wire work and glass as per Drg No CE JZ-70/06-07 dated 07.06.07 with guard bar including priming coat complete all as specified and directed.
S&F sheet glass 3mm thick ordinary quality , fixed with oil putty complete all as specified and directed.
S&F sheet glass pin headed 3mm thick ordinary quality , fixed with oil putty complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frame, glazed with putty and fixed with beads complete all as specified and directed.
S&F in repair sinks with drainage board made of stain less steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F in repair stainless steel kitchen plate rack size 900 x 600 x 300mm deep made out of 1mm thick sheet including fitting arrangement complete all as specified and directed
Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr and S&F rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including S&F 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod complete all as specified and directed
Taking down or up steel tubing 15mm bore and connections incl cleaning for refixing or removal to store complete all as specified and directed
S&F galvanised steel tubing 15mm bore “medium grade” with all fittings complete fixed to wall/ ceiling or laid in floors complete all as specified and directed
Refixing old steel tubing 15 mm dia and connections in new or old position (Walls, ceiling, floors, etc.)
Taking down or up steel tubing 20mm bore and connections incl cleaning for refixing or removal to store complete all as specified and directed
S&F galvanised steel tubing 20mm bore “medium grade” with all fittings complete fixed to wall/ ceiling or laid in floors complete all as specified and directed
Refixing old steel tubing 20 mm dia and connections in new or old position (Walls, ceiling, floors, etc.)
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting of required reconnecting and refixing in position or removling to store complete all as specified and directed.
S & F rotational moulded polytheylene triple layered white water storage tanks of capacity 500 Litres(cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing water tank and 20mm dia brass float valve with brass rod complete all as specified and directed.
Taking up and down S&F GI tubing 15mm bore medium grade, fixed to wall/ceiling or floor etc with all fittings ISI marked complete all as specified and directed.
Taking up and down GI tubing 15mm bore medium grade but fixing only (old serviceable pipe re-used).
Taking up and down S&F GI tubing 20mm bore medium grade, fixed to wall/ceiling or floor etc with all fittings ISI marked complete all as specified and directed.
Taking up and down GI tubing 20mm bore medium grade but fixing only (old serviceable pipe re-used).
S&F GI tubing 40mm bore medium grade, fixed to wall/ ceiling or floor etc with all fittings complete all as specified and directed including taking down.
Cutting existing steel tubing for alterations or additions and screwing existing steel tubing for alterations or additions ( or lengthening screw on pipe to form connector) for 15mm bore complete all as specified and directed.
S&F in repair bib taps 15mm dia chromium plated fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.
S&F 15 mm Bib taps standard of PTMT any colour screwed, for iron pipe and fixed (Minimum weight 15 mm- 90 gms/20mm-25 gms)
S&F stop valves fancy type 15mm bore chromium plated alloy with butterfly handle screwed down for high pressure, screed on bath ends, fixed with iron pipe etc complete all as specified and directed.
S&F in repair stop value 20mm bore cast copper alloy with butterfly handle screwed down for high pressure, screed on bath ends, fixed with iron pipe etc complete all as specified and directed.
S&F 15 mm stop cock screwed to iron pipe CP concealed type with long shank and capstan head for (Bath shower) complete all as specified and directed.
S&F in stop valves, 15mm of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms/ 20mm-92gms)
S&F in stop valves, 15mm of PTMT any colour high pressure screwed (Concealed type) for iron pipe and fixed. (Minimum weight15mm-90gms/ 20mm-92gms)
S&F in stop valves, 20mm of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms/ 20mm-92gms)
S&F in repair CP shower rose 125 mm size with swivel joint fancy type complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for ironpipe and fixed.
S&F 15mm Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms).
S&F 100mm dia CP grating with or without hinge type or hole type complete all specified and directed.
S&F CP brass towel rail `D’ type 60 Cm long fixed to wall complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous china squatting pan “Orrisa Pattern” white of size 580x440mm with internal foot rest with `P’ or `S’ trap, integral foot rest including water connection to trap and flushing pipe, flushing cistern etc complete and bedding in PCC 1:7:12 type F-2 complete all as specified and directed. Note:- Flush pipe and flushing cistern to be measured and paid separately.
Supply only Flush pipe of polythylene of low or high density or PVC,32mm dia for low level cistern.
S&F in vitreous China wash basin white,flat back size550x400mm including PTMT waste coupling 32mm bore with Pillar Tap complete.
S&F pvc waste pipe 32 mm dia 600-750 mm long fixed to wash basin/urinal all as specified and directed
Supply only PVC low level flushing cistern 10ltr capacity, with syphonic, action PVC float valve, brackets and 32mm bore PVC flush pipe etc complete all as specified and directed.
S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F glass corner shelf (12" x 12") with brass brackets of heavy duty and thickness of glass min 6mm and fixed complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings , heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories
S&F 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engr-in-charg,
S&F 110mm bore PVC(SWR) pipes single socketed in any length in trenches/floor with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engr-in-charg,
S&F 75mm bore PVC(SWR) pipes single socketed in any length with rubber ring joint, fixed to walls including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings complete all as specified and directed by Engr-in-charge.
S&F 75mm bore PVC(SWR) pipes single socketed in any length in trenches/floor with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engr-in-charg.
S&F 110mm bore PVC (SWR) bends any radius With access door
All as per Srl item No 125 here in before But 75mm bore.
S&F 110 mm bore( SWR) vent cowl
M&L 75mm bore PVC (SWR) floor trap ,plain with grating including jointing with solvent cement
S&F 110mm bore PVC (SWR) junction single/double, (single/double T), equal or unequal with access door.
All as per Srl item No 129 above but 75mm bore.
Dismantling of cast iron ,PVC or SGSW drain pipes, jointed in cement mortar and taking out of trenches , if required.
S&F Cast iron soil pipes 100mm bore, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or on wall complete all as specified and directed.
S&F Cast iron soil pipes 75mm bore, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or on wall complete all as specified and directed.
S&F 100mm CI bends with oval access door complete all as specified and directed.
S&F 75mm CI bends with oval access door complete all as specified and directed.
S & F 100 bore CI Branch pieces (Single T), single (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches with oval access door complete all as specified and directed.
S&F CI vent cowl of size 100mm complete all as specified and directed.
S&F CI vent cowl of size 75mm complete all as specified and directed.
M&L for CI floor trap with grating incl joint 100mm dia complete all as specified and directed.
M&L for CI floor trap with grating incl joint 75mm dia complete all as specified and directed.
S & F Stack clamps (100 mm pipe) out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F Stack clamps (75 mm pipe) out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coat of synthetic enamel paint over one coat of primer complete all as specified and directed.
Supply and fixing in repair cutrain rod 20mm dia of anodised aluminium alloys with fixing brackets, stops, rollers etc fixed to wall with screws, PVC plug including taking down existing curtain rod complete all as specified and directed.
Dismantling of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed
M&L for brick work with sub class 'B' brick straight curved on plan exv 6m mean radius built in CM 1:4 brick m slightly roundeda as wedged shaped as spd.ther part made of mild steel heavy duty in fixed complete all as specified and directed.
All as per Srl item No 146 above but except sub class 'B' bricks (old dismantled serviceable bricks obtained from Srl item No 145 above shall be reused after necessary cleaning of mortar)
M&L brick with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc.
M & L for Marble work 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars window cills , cooking platforms , stair case and like in cement mortar ( 1:4) incl pointing in white cement ( 1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed and approved by Engg-in-charge
M&L 100mm thick cement concrete type D-2, 1:4:8 (using 40mm stone aggregate) as in sub base complete all as specified and directed.
M&L for 60mm thick PCC (M-35) factory made coloured interlocking tiles/ paver block of shape/ size as conforming to IS 15658 , joints will be filled with fine sand complete all as specified and directed by Engineer-in-Charge. Note :- Sand will be paid under relavent item.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floor & paving n.exc 15cm above ground level.
M&L for cement cocnrete type B-1 (1:2:4) (20mm graded aggregate) as in plinth protection as thickiness of 50mm without using extra cement complete all as specified.
M&L for Granite 20mm thick(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Dismantling floor, hearth or wall tiling incl cement mortar (but not backing) and removing rubbish to a distance exc 50M but n.exc 100M away to the low laying area, complete all as specified and directed.
S&F for vitrified ceramic tiles 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed .
S&F non skid ceramic light coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & complete all as specified and directed.
S&F glazed ceramic dark coloured tiles 350x250mmx7mm/450X 350X 7mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface and taking down of old existing treatment & plaster, scrubbing down with water and disposing off the wastage to low laying areas to a distance exceeding 50 Mtr but not exceeding 100 Mtr away complete all as specified and directed.
Excavation in trenches n. exc 1.5 m wide and n exc 1.5 deep in depth for foundation etc or for shafts, wells, esspits, manholes, pier holes etc not exc 10 Sqm on plan and n. exc 1.5 m in depth and getting out complete all as specified and directed.
Returning filling in , including spreading, levelling, watering and well ramming in layers n. exc 25cm complete all as specified and directed.
Removing excavated material n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed.
Demolation and breaking up drain pipe (Salt Glazed ware) 150mm bore set in cement morter.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) bedding for sewage line of 150mm dia incl packing under and haunching agaisnt the sides of the pipes after they are laid and tested, complete all as specified and directed.
Supplying, laying in trenches, jointing and testing SGSW pipe grade 'A' drain pipes 150mm bore confirm to IS-, at a ny depth over PCC bed, complete all as specified and directed. (Excavation and earth work shall be measured and paid for seperately under appropriate items of shedule 'A'.
Demolition and breaking up old unserviceable drain pipes (salt glazed ware, AC or reinforced concrete) 150mm bore at any depth set in cement mortar including PCC bed complete all as specified and directed.
M&L for PCC 1:4:8 type B-1 (using 20mm graded stone aggregate) as as in concrete bed to drain pipe including packing and haunches etc complete all as specified and directed.
Supplying, laying in trenches , jointing and testing salt glazed stoneware drain pipes grade 'A' drain pipe 150mm conforming to IS at any depth over PCC bed complete laid in trenches and jointed as specified and directed.
M&L for precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as cover slab for manholes and similar work etc complete all as specified and diected.
M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in Shelves incl. demolition complete all as specified and directed.
Use and waste of form work to Chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges rough finished flat surfaces of concrete complete all as specified and directed
M&L TMT bars 6 to 8 mm dia and over cut to length bent to shape required including crancking spirally for hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed.
M&L for chequered cement concrete tiles colured 30cmx30 cmx25mm thick, set jointed and pointed in neat cement slurry with pigment complete in floor including 15mm thick screed bed in CM 1:4.
S&F MS stays for rainwater pipe made up of FI 25x3 mm conforming to Fe-410-0 or FE-310-0 complete all as spcd and directed
E/M PORTION Taking down carefully aluminium/copper point wiring for light, fan, bell, socket of point complete fittings such as switches. Ceiling roses, pendents, Regulator Socket etc complete at site and making goods disturbed surfaces of walls, floors etc.
M & L in replacement of Point wiring with PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm, FRLS through and including concealed PVC conduit with fittings and PVC insulated, unsheathed multistranded, copper conductor cable continious earth wire of size 1.5 sqmm, FRLS, connected to common earth and modular sunken boxes for mounting of accessories complete for one light point/fan point/ call bell point controlled by one one way swithch all as specified and directed. Note :- Cost of making good the disturbed surface plastering/filling putty alongwith matching with the existing colour with MES Approved make of distemper is deemed to be included in the quoted rate by contractor. One light/fan/bell point controlled by one one way modular switch,
All as per Srl item No 177 above but modular socket 6A multipin 2 module on independent board.
All as per Srl item No 177 above modular socket, 6A multipurposes 2 module on same board.
All as per item 177 above but one light point controlled by two way switches.
All as per item Ser No 177 above but cable size 2.5 sq mm , FRLS, for One modular socket 16A multipin 2 module on independent board.
M&L for sub main wiring with two single core multi stranded PVC insulated, unsheathed copper conductor of grade 1100 Volt , FRLS cable of size 6 sqmm (red for phase and black for neutral) and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 32 mm wide & 6 sqmm multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth duly complete and taking down old unserviceable one. Note :- (a) Cost of making good the disturbed surface plastering/filling putty alongwith matching with the existing colour with MES Approval make of distemper is deemed to be included in the quoted rate by contractor. (b) Three run of cable alongwith PVC conduit together shall be measured as single run.
S&F modular switch one way ,1 module 6 amps single pole complete all as specified and directed.
S&F modular socket 6A multipin one module complete all as specified and directed.
S&F modular switch one way 16 amps one module single pole complete all as specified and directed.
S&F modular socket, 6A/16A multipin combined 2 module complete all as specified and directed.
S&F switch modular 2 way 6A one module complete all as specified and directed.
S&F in replacement surface mounting universal batten housing made of powder coated CRCA sheet fixed on and including 02 Nos PVC square blocks suitable for and upto 1 x 18/20 W LED tube rod and taking down old unserviceable fitting complete all as specified and as directed.
S&F LED tube light 20W ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting 1 x 18/20 W tube light batten fitting all as directed. Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
Taking down carefully ceiling fan complete from site removing Fans are deposited to MES storeyard and re-fixing after completion of work at the site .
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete including replacement of one pair of Canopy.
S&F in replacement of modular fan regulator 2 module electronic type 5 step 100watt,240 Volt and connecting complete all as specified and directed all as directed.
S&F Bell, AC, 230 volts ding dong, single pole complete all as specified & directed.
S&F bell push modular type 6 Amp 1 module complete all as specified and directed.
S&F lamp holder PVC body angle type including 9 watt LED bulb polycarbonate body complete all as specified and directed.
M&L ceiling rose, surface bakelite 65x50mm three terminal .
S &F modular white cover plate with frame, 1/2 module complete all as specified and directed.
S &F modular white cover plate with frame, 3 module complete all as specified and directed.
S &F modular white cover plate with frame, 8 module complete all as specified and directed.
S &F modular white cover plate with frame, 12 module complete all as specified and directed.
S &F modular metal flush box, 1/2 module complete all as specified and directed.
S &F modular metal flush box, 3 module complete all as specified and directed.
S &F modular metal flush box, 8 module complete all as specified and directed.
S &F modular metal flush box, 12 module complete all as specified and directed.
S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron of size 32 mm thick with nuts & bolts, washers complete including dismentling the existing GI pipe bracket and drilling of holes for nuts & bolts etc all as specified and directed
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete.
Supplying and fixed in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed. Note : All the connection of incoming and out goiing wire in MCB will be made with thimble with suitable size as directed.
S& F in repair MCB single pole 6 amps to 32 amps , 'B' series complete all as specified and directed.
All as per item Ser No 208 above but 'C' series complete all as specified and directed.
All as per Item Ser No 208 above but single pole and neutral 32 - 40 amps , C series complete all as specified and directed.
M&L LT panel board indoor type of 2 mm thickness compartmentalise fixed on wall including grouting firmly to wall having independent opening for each compartment at front and panel painted with two coat of powder paint over a coat of red oxide primer prewired with copper cable multistranded of suitable ampacity, made by CPRI approved firm, making connections and comprising of followings:- (a) MCCB 100 Amp 4 pole 16 KA, 50 HZ-01 No (Incoming). (b) MCB, SPN 40 Amp, 10 KA -04 Nos (outgoing ) (c) Busbar chamber with aluminium bus bar of 200 amp[s rating 04 Nos all along the length of the panel 01 set (d) Refixing the single phase energy meter 5-30 A 240 volt AC LCD display with optical port -04 Nos (e) Cable glands/lugs and rubber bushes, etc for incoming and outgoing circuits,.
Earthing complete with galvanised steel earth plate electrode 60cm ×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removing excavation material n. exc 50 mtr and depositing wher directed at a level n. exe 1.5 mtr above the starting point.
Supply and lay brick common burnt sub class "B" old size and for protection of cable laid in trenches for under ground cable all as specified.
M & L Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified
Supply and fixing steel water tubing galvanised 50 mm dia medium grade laid in trenches/wall including all necessary fittings complete and connecting to existing system including taking down old one all as specified and directed by Engineer-in charge.
Supply and fixing steel water tubing galvanised 25 mm dia medium grade laid in trenches/wall including all necessary fittings complete and connecting to existing system including taking down old one all as specified and directed by Engineer-in charge.
Supply and fixing steel water tubing galvanised 20 mm dia medium grade with all fittings and fixed complete to wall and ceiling including drill hole on wass for in coming and and out going pipe. wall including all necessary fittings complete and connecting to existing system all as directed by Engineer-in charge.
Supply and fixing Gun Metal Gate valve dia 25 mm with iron wheel head screwed both ends for GI pipe including old one of the following dia all as directed
Supply and fixing Gun Metal Gate valve dia 20 mm with iron wheel head screwed both ends for GI pipe including old one all as directed.
S&F bib taps fancy type chromium plated for iron pipe 15mm dia.
Supply and fix PVC connection 15 mm dia PTMT nuts of lenth 300 mm .
M&L for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 40 mm bore with necessary clamps all as directed.
Supply and fixing MCB protected socket outlet suitable 5/15 amp made of sheet encloser plastic cover plate complete with one no 20 amp MCB SP 'C' series all as specified and directed as per Havells Model No DBOX equivalent indoasian/standard.
MALKIT SINGH AND SONS
KAILASH CONSTRUCTION CO
RAM CHAND SAINI & BROS.
RATTAN CHAND CHANDAN AND CO
buta singh and sons
multani construction co
Harbhajan electric co
M/s kulwant singh and sons
JOGRAJ CONSTRUCTION COMPANY
P S BUILDERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .