Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹39.5 L+₹3.0 L (8.28%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance Not being a
lowest
tenderer | |
| 3 | L3₹46.3 L+₹9.8 L (27.0%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Not being a
lowest
tenderer | |
| 4 | L4₹49.1 L+₹12.6 L (34.5%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Not being a
lowest
tenderer | |
| 5 | L5₹53.3 L+₹16.8 L (46.1%)Rejected-Finance | L5 | Rejected-Finance Not being a
lowest
tenderer |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
3 Mar 2021, 6:00 pmClosed
GE BABINA
GE BABINA CANTT 284401
REPAIR/ MAINT IMPROVEMENT OF WATER SUPPLY RISING MAIN AND DISTRIBUTION SYSTEM WITH CONNECTED WORKS AT SWIMMING POOL KLP, SAF,FASF AREA AND COMPREHENSIVE MAINT OF SEWAGE INSTALLATION AND MBBR BASED STP OF CAPACITY 300KLD AT MAP PH-II UNDER GE BABINA
2021_MES_410482_2
GE/BAB/TOKEN /66 OF 2020-2021
Open Tender
Civil Works - Water Works
Item Rate
330 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹1 L
Yes
22 Apr 2021
13 Feb 2021
5 Mar 2021
13 Feb 2021
3 Mar 2021
19 Feb 2021
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth and getting out for laying of pipe lines in any type of soil.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm each in soil.
Removal of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point.
M & L for cutting of stone pavement/road a depth up to 1.5 mtr below the normal ground level and in width equal to external dia plus 300 mm for laying of pipe line upto 300 mm dia across the road in horizontal position and making good the cut portion filled with PCC 1:3:6 type C-2 using 40 mm graded stone aggregates 450 mm thick from TOP over 300 mm thick hard core of gauge n exc 63 mm graded stone aggregates over filled earth , to levelled with existing surfaces for smooth plying of vehicles etc complete and directed. Note : Cost of PCC ,hard core,stones and Earth work shall deemed to be included in unit rate quoted by the tenderer.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removal of debris complete all as specified and directed
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundations /mass concrete etc complete all as specified and directed.
M&L for 100 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate laid in alternate panels n exc 12 sqm each forming joints with 10 mm thick commercial plywood and joints filled with sealing compound grade 'A' , as in hard standing /foot path etc complete all as specified and directed. Note : The cost of materails for forming joints and filling joints deemed to be included in unit rate quoted by the tenderer.
M&L for taking up or down GI water tubing with fittings and connections from wall/roof/floor or trench of 15 mm dia including removing from site to different location complete all as specified and directed. Note for item 7 to 13:- Necessary earth work /excavation , RFR and removing of soils shall be measured & paid separatly under relevant items.
Discription all as per item No 08 here in before but of size 20 mm bore
Discription all as per item No 08 here in before but of size 25 mm bore
Discription all as per item No 08 here in before but of size 40 mm bore
Discription all as per per item No 08 here in before but of size 50 mm bore
Discription all as per per item No 08 here in before but of size 65 mm bore
Discription all as per per item No 08 here in before but of size 80 mm bore
Discription all as per per item No 08 here in before but of size 100 mm bore
Re-laying / re-fixing serviceable GI water tubing 15 mm bore obtained from dismantling incl cleaning and providing new all fittings such as bends, elbow, socket , tee ( ISI Marked ) laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed.
Discription all as per item No 16 here in before but of size 20 mm bore and ditto
Discription all as per item No 16 here in before but of size 25 mm bore and ditto
Discription all as per item No 16 here in before but of size 40 mm bore and ditto
Discription all as per item No 16 here in before but of size 50 mm bore and ditto
Discription all as per item No 16 here in before but of size 80 mm bore and ditto
Discription all as per item No 16 here in before but of size 100 mm bore and ditto
S & F GI water tubing medium grade 15 mm bore with all fittings such as bends, elbow, socket , tee etc laid under floors/trenches or on walls with fixing arrangments including leakage testing complete all as specified and directed. Make : TATA/PRAKASH/ZENITH /SWASTIK/BST
Discription as per item No 23 here in before but of size 20 mm bore and ditto
Discription as per item No 23 here in before but of size 25 mm bore and ditto
Discription as per item No 23 here in before but of size 40 mm bore and ditto
Discription as per item No 23 here in before but of size 50 mm bore and ditto
Discription as per item No 23 here in before but of size 65 mm bore and ditto
Discription as per item No 23 here in before but of size 80 mm bore and ditto
Discription as per item No 23 here in before but of size 100 mm bore and ditto
S & F in replacement of gun metal gate valve of size 15 mm bore ( ISI marked ) with iron wheel head, screwed both ends for GI pipe incl dismantling old U/S gate valves all as specified and directed. Make : Leader/Sant/Zoloto
Discription as per item No 31 here in before but 20 mm bore and ditto
Discription as per item No 31 here in before but 25 mm bore and ditto
Discription as per item No 31 here in before but 40 mm bore and ditto
Discription as per item No 31 here in before but 50 mm bore and ditto
M&L for boring on existing GI/CI/DI pipe upto 300 mm bore for branch connections of 25 to 50 mm bore by fixing of MS clamp 100 x 4 mm cut to length and bend to shape, drilled and welded with GI socket of suitable size including rubber packing, nut, bolt etc and testing complete all as specified.
M & L for cutting of GI/DI/CI pipe 80 to 300 mm bore carefully for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed.
M&L for taking up or down CI/DI water mains with spigot and socket ends and lead joints including of size 80 bore including all fittings and connections including burning of joints and recovering leads and cleaning thoroughly for re-relaying / rerouting of pipe line complete all as specified and directed. Note:- Necessary excavation refilling removing of soil shall be measured & paid separatly under relevant items.
Discription as per item No 38 here in before but of size 100 mm bore and ditto
Discription as per item No 38 here in before but of size 150 mm bore and ditto
Discription as per item No 38 here in before but of size 200 mm bore and ditto
Discription as per item No 38 here in before but of size 250 mm bore and ditto
Discription as per item No 38 here in before but of size 300 mm bore and ditto
M&L for relaying/refixing, jointing and testing of DI/CI pipe of 80 mm bore all as specified and directed. Note :- Cost of all jointing materials required at site like rubber ring joint included in the quoted rate, earthwork shall be measured and paid separately.
Discription as per item No 44 above but 100 mm bore and ditto
Discription as per item No 44 above but 150 mm bore and ditto
Discription as per item No 44 above but 200 mm bore and ditto
Discription as per item No 44 above but 250 mm bore and ditto
Discription as per item No 44 above but 300 mm bore and ditto
S & F in replacement ductile iron pipe with socket and spigot ends of 80 mm bore class - K-9 , with ceramic epoxy lining /coating inside and external zinc coating with a bitumen finishing layer , ISI maked IS - 8329-2000 (Reaffiremed - 2005 Edition 4.1) suitable for "push on joints" in any lengths and including providing joints (Tyton joints) including taking out from vertical position or from trenches etc complete all as specified.Make : Lanco industries /Electro steel /Electrotherm (India ) steel /Jindal Saw /TATA Metalics . Notefor item No 47 to 52 : The cost of joints shall deemed to be included in unit rate quoted by the tenderer. (Excavation and earth work shall be measured and paid seperately
Discription as per item No 50 here in before but 100 mm bore and ditto
Discription as per item No 50 here in before but 150 mm bore and ditto
Discription as per item No 50 here in before but 200 mm bore and ditto
Discription as per item No 50 here in before but 250 mm bore and ditto
Discription as per item No 50 here in before but 300 mm bore and ditto
S & F in replacement of cast iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make: VENUS/NORMAX/KIRLOSKAR/KEJRIWAL/SANT/UPADHYA Note:- Contractor will be intimated to replace the diffective sluice balve on telephonically followed by in written. Contractor has to arrange new sluvice valves and complete the replacement work with 48 hrs after intimation failing which a penal recovery of Rs 500/- per hour will be charged from his payment. Contractor has to keep all required size sluice valve ready for fixing on urgent requirment.
Discriptionl as per item No 56 here in before but 100 mm bore
Discription as per item No 56 here in before but 150 mm bore
Discription as per item No 56 here in before but 200 mm bore
Discription as per item No 56 here in before but 250 mm bore
Discription as per item No 56 here in before but 300 mm bore
S & F in replacement of 80 mm bore non return valve ( ISI Marked ) both end flanged suitable for cast iron pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. Make : Make : VENUS/LEADER/KIRLOSKAR/SANT/ZOLOTO
Discriptionl as per item No 62 here in before but 100 mm bore and ditto
Discriptionl as per item No 62 here in before but 150 mm bore and ditto
Discriptionl as per item No 62 here in before but 200 mm bore and ditto
S & F in replacement cast iron foot valve of 100 mm size with flanged end IS-4038 including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed. Make : VENUS/NORMAX/KIRLOSKAR/KEJRIWAL/SANT/UPADHYA / L&T
Discription as per item No 66 here in before but 150 mm bore and ditto
Discription as per item No 66 here in before but 200 mm bore and ditto
S & F in replacement of 50 mm bore air release valve double chamber as per IS 14845 including mounting GI pipe and clamps as per requirement at site suitable for cast iron pipe/ ductile iron pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. Make : VENUS/NORMAX/KIRLOSKAR/KEJRIWAL/SANT/UPADHYA /L&T
S & F in replacement of 100 mm bore air release valve double chamber as per IS 14845 including mounting GI pipe and clamps as per requirement at site suitable for cast iron pipe/ ductile iron pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. Make : VENUS/NORMAX/KIRLOSKAR/KEJRIWAL/SANT/UPADHYA
Supplying ,fixing ,jointing and testing DI fittings as per BSEN:545 IS-9523 such as bend ( of any radius and angle) Tee ,reducer ,collar caps ,plugs ,glands ,tapers and junctions etc of any description with socket/spigot/flanged at ends as per site requirement suitable for 80 to 300 mm bore complete all as specified and directed .
M & L for cast iron fittings of any description i.e bends (any type radius and angle ),tappers any type (straight ,bend increasing decreasing or double socket etc ),Tee pieces single branch Y junction ,double branch cross,(all socketed or socket and spigot),connecting pieces (one side flanged other socketed or spigot and bell mouth pieces one end flanged other tapering as bell mouth or both flanged /both socketed end as directed ) including collars ,caps and plugs upto 300 mm bore pipe and including nut bolts ,packing materials etc and making joint leak proof complete all as specified and directed . NOTE:-(i) Weight of fitting shall be actual weight or weight for each fitting given in IS code IS-1538-1976 (Part-I to xxv)
M & L for repairing leakages or blockage of water in CI/DI pipes with spigot and socket ends of 50 to 80 mm dia bore de-watering of leaking pipe lines and trenches, burning out remains of existing lead joints to recover available quantity of lead and making new lead joint with retrieved material by providing additional quantity of lead as required at site incl all other jointing materials and testing complete all as specified and as directed. Notes : 1. Total excavation and earth work and required T & P/JCB excavation/manual labour as required at site to carry out the repair work is deemed to be included in the quoted rates. No separate cost for earth work claim by the contractor.2. Actual quantity of lead retrieved from leaking joints may vary from joint to joint and the same be considered to the barest minimum owing to loss due to high pressure of water jet and flooding of water from the joints. 3. No any claim whatsoever in this regard by the contractor for loss or non-retrival of jointing materials shall be admissible and the rate quoted is deemed to be inclusive of this aspect. Note:- Contractor will be intimated telephonically followed in writing for attending the leakages/broken or no water supply defects or repair works under this item.The defects or repair works under this item. Will be attended with in 4 Hrs of intimation and work will be completed within 24 Hrs ofter intimation of defects failing which a penal recovery of Rs 1000/- per hour will be deducted from contractor's payments. Contractor has to arrange all T & P and manpower to attend defects on time without any extra financial effectand cost of all such aspect is deemed to be imcluded in unit rate. Contractor has to arrange all means to stop leakage/wastage of water and restore water supply without delay.
Discription as per item No 73 here in before but 100 mm bore and ditto
Discription as per item No 73 here in before but 150 mm bore and ditto
Discription as per item No 73 here in before but 200 mm bore and ditto
Discription as per item No 73 here in before but 250 mm bore and ditto
Discription as per item No 73 here in before but 300 mm bore and ditto
M&L for Construction of Valve pit of size 1050 mm x 1050 mm x 900 mm (internal dimensions), with the following specifications : (a) Earth/excavation in any type of soils , RFR & removal of soils n exc 50 mtr and deposited where directed , (b) Lean concrete 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggreagtes as in foundation and floor (c) One brick thick wall with sub class 'B' built in CM 1:6 ( d) Internal plaster / Rendering 15 mm thick in CM 1:4 mixed with WPC @ 3% by weight of cement (e) External plaster/rendering 15 mm thick in CM:1:6 (f) Coping alround on wall 100 mm thick in PCC 1:2:4 type B-1 using 20 mm graded stone aggregates incl necessary form work (g) Mild steel frame work ( Outer frame and inner frame ) made out of angle iron 50x50x6 mm thick with welded hold fast of flat iron of size 30x5 mm length 100 mm (one end splited in two grouted in PCC coping and other end welded to inner frame ) , provision of mild steel butt hinges 100 mm - 4 nos , one flap welded to outer frame and other to inner frame ( h) 3.15 mm thck mild steel sheet as covering welded to inner frame j) Mild steel purpose made locking arrangement and provision of pad lock , 50 mm size ( steel) with duplicate keys ( Make of lock -Godraj/Link/Horrison) and mild steel handle of flat iron 30x5 mm thick made to shape and welded to mild steel sheet (j) Applying two coats of sythtic enamel paint over a coat of red oxide primer to steel surfaces k) Two coats of white wash on internal and external surfcaes of plaster on walls mortar etc complete all as specified and as directed . Note : The cost of demolition of existing valve pit deemed to be included in the unit quoted rate by the tenderer.
Discription as per item No 79 here in before but 950 x 950 x 600 mm and ditto
M & L for cleaning of RCC overhead reservoir of 25000 gallon capacity on staging of 17 to 21 mtr grom GL , Dewatering, taking out all deposits sludge / mud incl scrubbing/brushing to remove all funges growth inside the entire interior surfaces of the reservoir ,and including washing the reservoir thoroughly ( internally ) cleaning with bleaching powder including writing of date of cleaning with existing colour and paint complete all as specified and directed by Engr-in-Charge. Note : 1. All necessary T & P required for cleaning OHT/UG sump is deemed to de included in unit rate quoted. 2 Rate for dewatering UG sump/semi UG sump by using of diesel engine pump set is deemed to be included in the quoted rate. 3. All necessary safty precautions to be taken by contractor while cleaning to avoid any accident and contractor will be responsible for any lapes.
Discription as per item No 81 here in before but of 50000 gallon capacity
Discription as per item No 81 here in before but of 100000 gallon capacity
Discription as per item No 81 here in before but of 150000 gallon capacity
Discription as per item No 81 above but U/G sump 25000 to 50000 gallon capacity
Discription as per item No 81 above but U/G sump 300000 to 4000000 gallon capacity
M & L for cleaning of shallow wells of any depth dewatering by using diesel engine pump set and taking out of mud/silt/vegetation etc manually upto 1 mtr from exisitng bed of well & removal of the same away from MOD land complete all as specified and as directed by Engr-in-Charge. Note : 1. Rate for dewatering shallow wells by using of diesel engine pump set is deemed to be included in the quoted rate. 2. All necessary T & P required for cleaning OHT/UG sump is deemed to de included in unit rate quoted. 3. All necessary safty precaution to be taken by contractor while cleaning to avoid any accident any laps on this part contractor will be responsible for any lops.
S &F in replacement water line route indicator of size 400 x 300 x 25mm in precast RCC (1: 1:1-1/2:3 ) type A-0 using 12.5 mm graded stone aggregate and fixed in position after taking out old unserviceable indicator etc complete all as specified and directed. Note :- Route indicator should be written as MAIN WATER SUPPLY LINE with synthetic enamel paint of tint as directed .
M & L for chemical and bacteriological testing of water samples of shallow wells from Jal Nigam laboratory / any govt institution complete all as specified and directed. Note - The material and transportation for collection of samples quoted in the rate. The report will deposited to office after completion of test from the laboratory.
M&L for applying two coats of synthetic enamel paint including preparation of old/existing surface, rubbing and removing rust, worn out old paint layers and other foreigh materials and re-writing the same description as per existing with colour as approved for rising and distribution pipe line from semi UG sump to pump house, black colour paint on valve pit cover, valves, UG sump details on sump within the installations etc complete all as specified and directed.
S & F in repair sluice valves 80 mm dia bore of any size / make installed at water supply rising or distribution lines and incl dismantling and taking up or down of unserviceable SS / MS spindle and gun metal / bronze check nuts with replacement incl necessary rubber packing, nuts, bolts, washers etc and re-assembling in position after repair complete all as specified and directed.
All as per Srl item No. 91 here-in-before but 100 mm dia bore and ditto
All as per Srl item No. 91 here-in-before but 150 mm dia bore and ditto
All as per Srl item No. 91 here-in-before but 200 mm dia bore and ditto
All as per Srl item No. 91 here-in-before but 250 mm dia bore and ditto
All as per Srl item No. 91 here-in-before but 300 mm dia bore and ditto
M&L for repair of leakage/damage/defect in raising main through taking down the MS/GI pipe for ground level to OHT work after dismantling flange joints and including replacement of gaskeet /MS flang of same size if required and refixing the pipe on its original position vertially or horigentally of raising/supply line of OHT flanged type from ground level to top of the OHT of size 150 mm dia . The rate includes the dismantling of existing CI pipe of flanged type, sluice valve size as per fixed at OHT and for providing & welding of flanges on the pipes all as required and directed by the enginer in Charge. The contractor also ensure that the job will complete with in 24 hours to ensure the restoration of supply as directed.The quantity of water supply pipe and sluice valve laid/fitted will be measured and paid separately. Note:- The cost of taking down/dismantling any type of valves/flanges ect is deemed to be in included herein unit rate. the rate also included cost of necessary T & P man power required at site.
All as per Srl item No. 97 here-in-before but 200 mm dia and ditto
All as per Srl item No. 97 here-in-before but 250 mm dia and ditto
M&L for water level indicator of size minimum 3 mtr height and 30 mm width and consisiting of floating ball with guage wire from inside tank to level indicating board , duly marked scale as directed showing water level marked with flourcense paint and including provided with level indication scale made of 2 mm thick mild steel sheet duly painted with synthetic enamel paint over red oxide primer including necessary preparation steel surfcaes and fixed at a hight of 3 mtr from ground level etc complete for OHT's at various locations . Note : (i) The guage wire must be made with multistranded SWR of 3 mm dia shall be drawn through and including of 4 mm mild steel pully . (ii) Mild steel Pully shall be fixed at appropriate place as directed with suitable frame made of mild steel angle iron and flat iron of size as directed . (iii) The cost of Mild steel frame , SWR wire , mild steel pully and fixing element with suitable means deemed to be included in the unit rate quoted by the tenderer
M&L for Galvanised iron wiremesh to Ventilators , mouth of vent pipes, and entrance of OHT/UG sumps and fixing with 2nd class square wooden beads of suiatble cross section as directed inlcluding providing mild steel clamps of size 50x5 mm flat iron made to shape for pipes for fixing wiremesh duly painted with two coat of synthetic enamel paint over a coat of red oxide primer etc complete at various locations and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 3. metre deep below ground level with top edge of plate not less than 2.5 metre below normal ground level connected to earth plate.Earth plate surrounded by 15 cm thick packed layer of charcoal dust and comman salt upto 1.5 mtr depth all around the earth plate and connected to earth lead of GI strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel thimbles and other end of the earth wire connected to DB/motor/ panel/DG set and protected by GI or steel pipe light grade 15mm bore and watering pipe shall be 20mm bore GI medium with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electric plate No3 of MES schedule pt of 2009. Note:- RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4KG/Sqmm in lieu of CI cover. 2.Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers and 15 centumeters all around the earth plate inside earth pit. 3. On testing after completion of earthing if desired earth resistance is not achieved, the earthing will be redone at no extra cost to obtained the desired earth values less than 2 Ohms. Make of earth electrod : Kapilansh/ Ashlok/ JMV
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 3. metre deep below ground level with top edge of plate not less than 2.5 metre below normal ground level connected to earth plate.Earth plate surrounded by 15 cm thick packed layer of charcoal dust and comman salt upto 1.5 mtr depth all around the earth plate and connected to earth lead of GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel thimbles and other end of the earth wire connected to DB/motor/ panel/DG set and protected by GI or steel pipe light grade 15mm bore and watering pipe shall be 20mm bore GI medium with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electric plate No3 of MES schedule pt of 2009. Note:- RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4KG/Sqmm in lieu of CI cover. 2.Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers and 15 centumeters all around the earth plate inside earth pit. 3. On testing after completion of earthing if desired earth resistance is not achieved, the earthing will be redone at no extra cost to obtained the desired earth values less than 2 Ohms.
S & F in repair/replacement of DOL starter suitable for 10 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 8.9-13.5A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. Make : BCH cat part No CPEANK or L&T cat No SS94351 or equivalent specifications in Havells/HPL.
M & L taking out unserviceable submersible motar for rewinding of submersible motors AC, 3 phase, 440 volt 10 to 15 HP with superior quality PVC insulated copper winding wire of identical gauge & specification of the existing short circuited winding wires with all necessary insulating materials incl cleaning of stator & slots and applying one coat of water proof epoxy paint to the exteriors of motor and testing complete all as specified on load of capacity. Note:-Cost for all materials , T&P and menpower required deemed for included in unit rate quoted by the tenderer.
M & L for opening up short circuited electric induction motor of 15 to 30 HP capacity 3 phase AC 440 Volts, cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified.
S & F in replacement of MCCB, 4 Pole, 415 Volt AC, 50 Hz, rupturing capacity 36 KA with adjustable thermal and fixed magnetic tripping systems against over load and short circuit conditions of capacity 400 Amp conforming to IS:13947 (Part-2) Ics = 100%Icu Make : Havells Cat No. IHLLSEBFBF0400 or or equivalent specifications in L & T/ HPL /ABB/ LEGRAND/ SCHNIEDER.
S & F in replacement of MCCB, 4 Pole, AC, 415 V 50 Hz rupturing capacity 36 KA with adjustable thermal and fixed magnetic tripping systems against over load and short circuit conditions of capacity 250 Amp conforming to IS:13947 (Part-2) complete. Ics = 100%Icu Make : Havells cat part No IHLLSECF0250 or or equivalent specifications in L & T/ HPL /ABB/ LEGRAND/ SCHNIEDER.
S & F in replacement of MCCB four Pole AC , 415 Volt ,breaking capacity 25 KA with fixed thermal and fixed magnetic setting of capacity 100 Amp conforming to IS:13947- II complete all as specified and directed. Make- L & T/ HPL /ABB/ LEGRAND/ SCHNIEDER/HAVELLS
All as per item No 109 but MCCB capacity 160Amp and ditto
S & F of change over switch with advanced neutral, ON LOAD, 100 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including operating handle conforming to IS:13947 (Part-3) complete all as specified and directed. Make : L&T cat part No CO11000OSOO or equivalent specifications in Havells / HPL/ C&S
M & L for cutting and removing unwanted grass, bushes , wild growth and shrubs from the roots below ground level at various locations within the over head tanks premises about 15 mtr in radious around OHT , sewage insttalations and along with approach road/path and including removing boulders of any gauge by digging out from a depth not more than 25 cms below normal ground level and depositing where directed and including levelling / pruning the entire area to even finish complete all as specified and directed at site.
M&L for servicing of Sewage treatment plant based on moving bed bioreactor Aerobic attached growth technology manufactured by Fontus water pvt Ltd. including servicing ,checking and greacing/lubrication of 02 No Feed pump of Capacity up to 5 HP,Cleaning of one NO equalisation tank,greacing and testing of one Bar screen ,oil & grease trap,Cleaning ,checking of two moving bed bio reactor with media by visual checking of growth of Bio-Film and re-seeding of required quantity of MBBR media for propagate biofilm (bacteria colonies) and submit the report if effectiveness of the tratment plant. Servicing ,checking and greacing/lubrication of 02 Nos Filter feed pump and moter set of capacity 10HP to 15 HP,opening of 01 No dual media filter and 01 No activated carbon media filter and checking the condition of existing media ,cleaning and removing all sediment particles of sludge,mud ,sand,vegetation and refix at original position complete including testing and submit the test report of filtered water as per sewage charactristic for the treated water are followed under:- (i) BOD (PPM) Treated waste water < 30 (ii) COD (PPM) Treated waste water < 250 (iii) TSS (PPM) Treated waste water < 30 (iv) Oil & Grease Treated waste water <1000 Note A : 1. The plant shall be visited twice as directed during contract period by auth service technician/Engineer of Fontus water pvt ltd or equivalent STP manufacturing or authorised service patner company approved by GE and will check all parameter /defects and growth of biofilm on the MBBR media and submit report to Engineer in charge.All necessary repair /servicing will be done by auth service engineer .Cost visiting charges of engineer are deemed to be include in unit rate. 2. All spares/material reuired will be paid and measured separately against relevent items of schedule hereunder. Note B: The unit rate includes the following manadatory works (i) Checking of condition of MBBR media ,dual media and activated carbon media.changing of media shall be measured and paid separately. (ii) Carry out preventive maintenance as per the company recommandations and standard practice in every visit .Lubricating the bearing and motors & fans (iii) Checking the growth of biofilm observed on the MBBR media ,Biochemical Oxygen Demand (BOD) Removal efficiancy,range of F/M Ratio,Chemical Oxygen Demand (COD) Ratio and ensuring healthy condition of the plant. (iv) Taking set of reading and evaluating to ensure satisfactory performance of the plant (v) Checking of functioning of air blower in every visit and set the pressure required to propagete of the bacteria colonies. (vi) Checking the pump moter set of existing size and repair the leakage and greacing/lubrication of moving part. (Vii) Servicing/repairsworks will be carried out whitin 05 days after intimation to contractor on telephone followed in writing.Any delay beyound 05 day shall be penalised through panel recovery @ Rs 4000 per day till rectification/repair starts.
Supply and filling moving bed Biological MBBR biofilm filter media having approx size 25X12mm,cylindrical with external fins,white/black coloured for the treatment of sewage plant of capacity 300KLD including removal of existing MBBR filter media of any size and shape by dewatering the tank and removing all sedimented particles of sludge,mud,sand ,vegetation etc complete all as specified and directed. Make:Biotech india Ltd/Aquatech international/Weldone water system
M&L for top up activated carbon media consist of single layer of activated carbon supported by graveles and pabbles at bottom,coconut shell carbon and coal based carbon used ,adsorption capacity up to 90% chlorine ,colour and odour removal 85 to 90% , top up up to 40 cm and maintain media density 500-700 kg/m3 all as specified and directed by Engr-in-charge.
M&L for top up dual media consist of silica sand (16-32 mm mesh) and anthracite( 0.6-1.2mm) provide more area & efficient filteration ,supported by gravels and pebbles at bottom, topup silica sand up to 10 Cm thickness and top up anthracite up to 10 cm thickness to maintain the filteration level up to 40 microns complete all as specified and directed by Eng-in-Charge.
M&L Preparation of old surface by scraping and smoothing the surface with water emery paper and painting with approved colour of synthetic enemelled paint of two coat over a coat of primer red oxide and writing letter/numbers (SM/MES Nos and Date of Cleaning) of sewage treatment plant of capacity 300KLD and cleaning the surrounding area up to three meter outside area of the plant by cutting grasses and surface dressing for Moving Bed Bio Reactor 1 & 2etc complete all as specified and directed
All as per item No: 117 above but dual media filter
All as per item No: 117 above but Activated carbon filter
All as per item No: 117 above but Exposed water pipe lines
All as per item No: 117 above but Filter feed pump 1 & 2
All as per item No:117above but Distribution panel board
All as per item No:117 above but Air blower with compressor 1&2
Cleaning of sludge drying beds (04 nos) removing all sludge and de-scaling vegitation on the inside and outside of sludge bed and white washing (Two coat) including cleaning the surrounding area of the sludge drying beds to a distance of 3 meter circumstance including cutting of grass ,digging out roots ,filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete alll as specified and directed . Note: item Ser No:05 to18 (i) Adequate manpower including necessary T&P and safty precaution to the individual working /carry out job at site is the responsibility of the contractor and the cost include in the quotated rate. (ii) All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. (iii) The work mentioned in item Ser No 05 to 18 will be carried out within 07 days after intimation to contractor on telephonic followed in writing .Any delay beyound 07 days shall be penalished through panel recovery @ 1200 per day till rectification/repair.
All as per item No 124 but Equilization tank and air grid
All as per item No 124 but Bar screen and pit
All as per item No 124 but oil and grease trap
All as per item No 124 but Tube settler tank
All as per item No 124 but Clean water tank
All as per item No 124 but chlorine contact tank
Disconneting and taking down air compressor with 7.5HP electric motor carefully from foundation manually or mechanically and transporting to workshop for repair and back, installation, refixing, reconnecting to electric and piping work the repaired compressor complete all as specified and directed by Engr-in-Charge. Note:- (i) The quoted rate shall be deemed to include the cost of transportation, fixing of spare parts complete. Spare parts will be measured and paid for as supply only separately. (ii) Servicing / repairs works will be carried out whitin 03 days after intimation to contractor on telephone followed in writing.Any delay beyound 03 day shall be penalised through panel recovery @ 1000 per day till rectification/repair starts.
Supply and fixing non return valve suitable for 7.5 HP compressor
Supply and fixing cylinder liner suitable for 7.5 HP compressor
Supply only piston with 'O' ring suitable for 7.5 HP compressor
Supply only connecting rod suitable for 7.5 HP compressor
Supply only inlet valve suitable for 7.5 HP compressor
Supply only outlet valve suitable for 7.5 HP compressor
Supply only gasket set suitable for 7.5 HP compressor
Supply only piston pin suitable for 7.5 HP compressor
Supply only safety valve suitable for 7.5 HP compressor
Supply only pressure gauge suitable for 7.5 HP compressor
Supply and fix in replacement 3-layer PP-R polypropylene random copolymer pipe of Size 50 mm outer dia, SDR 11 UV stablised and antimicrobial welded having terminal stability for hot and cold water supply including all PP-R plain & brass treaded polypropylene random fitting fixed complete to walls,ceiling or infloor including all fitting such as bend tee,nipple etc complete all as specified and directed
Supply and fix in repair PP-R gate valve of size 50mm complete all as specified and directed.
Supply and fix air pluger valve of size 50 mm bore as per sample.
S&F in repalcement butterfly valve of Size 50mm dia all as specified and directed
S&F in repalcement PVC multiport valve of size 50mm bore suitable for sewage treatment plant as per sample
Supply only CRT based liquid chlorine (sodium hypochloride) solution along with stable buffer having chlorine content 10-13 % in 25 / 30 / 35 Ltr jar factory sealed non returnable containers complete all as specified and directed ( Make : As per approved by GE )
M&L for PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade single core 16 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed
Supply and Fix in repair cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cable(heavy duty) 1100V grade with stranded aluminium conductor of Size 35 SqmmX3.5 core including taking out of existing cable all as specified and directed
As per item No : 149 but Cable of size 25 SqmmX3.5 core
As per item No :149 but Cable of size 16 SqmmX4 core
Taking out the burnt electric motor of capacity 2 HP to 5 HP from existing position, transporting to civil work shop, separating the stator and rotor housing, cutting and removing the existing winding of stator completely, cleaning the slots and rewinding with existing gauge of super enamelled copper winding wire with suitable insulation, applying insulation varnish and heating in heating chamber till completely dried and reassembling the motor including supply and replacement of DE(01 No.) &NDE(01 No) bearings (make: NBC/SKF/TATA), transporting back to site and re-installing in its original position including proper alignment for smooth running and testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No 152 but electric motor of capacity 7 HP to 10 HP
All as per item No 152 but electric motor of capacity 12 HP to 15 HP
All as per item No 152 but electric motor of capacity 16 HP to 25 HP
Supply only terminal connector for 2 HP to 25 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
Supply only 2 HP to 25 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed.
Repairs to rotors of squirrel cage induction motor 2 HP to 25 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed.
Supply only star rubber bush coupling for motor 2 HP to 25 HP complete all as specified and directed.
Supply only star coupling key any size as per sample complete all as specified and directed.
Dismantling and taking up unserviceable non clogging type centrifugal pump sets of size 2 HP to 10 HP from foundations after disconnecting electric and water connections and transportation from site to contractor's work shop for carrying out repairs to pump sets as required incluidng re- assembling, re-fixing in position, including connecting and testing complete as specified and directed. Notes:- (i) Spare parts for pumps shall be measured and paid separately under respective items of this schedule. (ii) Transportation charges of pump sets from MES installations to contractors work shop and back is deemed to be included in the quoted rates. (iii) Pump sets issued for repairs / re-winding shall be returned back / re-installed at site within seven days from the date of receipt by the contractor. Any delay boyond 7 days shall be compensated through penal recovery @ Rs. 200 per day per pump set. (iv) Rates for minor items such as nut bolts, washers, thimbles, lugs, etc are deemed to be included in the quoted rates.
All as per item N0 : 161 but pump sets of size 12 HP to 25 HP
M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 2 HP to 10 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 12 HP to 25 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 2 HP to 10 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 12 HP to 25 HP complete all as specified and directed.
S&F in replacement of gun metal bush complete set of two as per sample for 2 HP to 10 HP complete all as specified and directed.
S&F in replacement of gun metal bush complete set of two as per sample for 12 HP to 25 HP complete all as specified and directed.
S&F in replacement of gun metal sleeves complete set of two Nos for 2 HP to 10 HP complete all as specified and directed.
S&F in replacement of gun metal sleeves complete set of two Nos for 12 HP to 25 HP complete all as specified and directed.
M&L for cleaning of sludge chamber at W Wing sewage plant having dia up to 4.5mtr and depth up to 7 mtr manually including de-watering and removing all sedimented particles of sludge,mud,sand ,vegetation etc,from the clarifer sump and deposting where directed at a distance not exceeding 50mtr including brushing / scrubbing to remove all scales or any fungus growth from the entire surfaces and cleaning thoroughly with fresh water and applying a coat of lime wash to the entire interior surfaces all as specified. Note:(1) Adequate manpower inxluding necessary T&P, safety precaution to the individual working/carry out job at site is the responsibility of the contractor and the cost include in the quoted rate. (2)All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. (iii) Cleaning works will be carried out whitin 07 days after intimation to contractor on telephone followed in writing.Any delay beyound 07 day shall be penalised through panel recovery @ 1500 per day till cleaning starts.
All as per item No: 171 but ISF line sewage plant
All as per item No: 171 but Zone 12 sewage plant
All as per item No: 171 but Zone 4 sewage plant
All as per item No: 171 but Zone 8 sewage plant
All as per item No: 171 but Zone 3 sewage plant
All as per item No: 171 but Bos line sewage plant
M&L for the empty of slude chamber with the help of diesal driven pump set having suction up to 7 mtr and discharge up to 10Mtr from the slude chamber all as specified and directed by Engr-in-charge Note:- (i) Diesal and transporting is deemed to be included in the quoted rates. (ii) Empty the sludge chamber is carried out within one day from the date of receipt by the contractor. Any delay boyond 1 days shall be compensated through penal recovery @ Rs. 500 per day per installation
Supply and fix in replacement electrical insulating mats conforming toIS 15652/2006 for 11 KV grade system 1mtr x 2mtr sheet thickness 3mm one side plain other side chequred/patterened moisture proof, fire retardant complete all as specified and directed .
S&F in replacement of mild steel foundation channel support assembly made out of MS channel size 4X10cm having thickness of 4 mm suitable for monoblock pump moter set of capacity 2 HP to 25 HP coupled with suction/delivery pipes of size 150mm/100mm/80mm/50mm/40mm with necessary bolts complete all as specified and directed Note:Provision of connection withn existing suction/delivery pipe including proper alignment necessary bushing,tapers,reducesers,MS flange ,welding work,etc as required at site for commissioning of pump sets in deemed to be included in the quoted rates.
supply and fix fully automatic star-delta starter for sewage plant capacity from exceeding 10 to 15 HP complete all as specified and directed . Make L&T/Havells/C&S
supply and fix fully automatic star-delta starter for sewage plant capacity from exceeding 16 to 25 HP complete all as specified and directed . Make L&T/Havells/C&S
Supply and fixing in replacement of 1000 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISI marked of make as specified cylindrical vertical with closed top hoisted and fixing in position including 20mm GI pipe medieum grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 1000 tr complete all as directed make -syntex / poywell / rotex
Supply and fix PVC bib tape of size 25 mm bore etc complete Make : Prayag/Symet/Shakti
Supply and fix PVC bib tape of size 20 mm bore Make : Prayag/Symet/Shakti
M&L for 100 thick PCC(1:3:6) type C1 (using 20mm graded crushed stone agregate) as in hard standing /pavement laid in alternate panels made of 10 mm thick plywood ( Size of each panel shall not exceed 12 Sqm ) and finish the surface even and smooth without using extra cement including filling of joint with bitumen mastic ( 1 part bitumen mixed with 3 part dry sand) etc complete all as specified and as directed. Note : Cost of form work for forming joints and jointing materials deemed to be included in unit rate quoted by the tenderer.
M&L for MS Fabrication work,made out of structural steel sections as in frame work for cable & piping ducts/MS door panels etc at sewage installation ,MS angle /flats/plain sheet of appropriate gauge ,cut to size and made to the existing shape suitable for fixing MS chequred duct cover /door panel including nut and bolts and washers ,welding bracing work bending cold or hot drilling holes for bolts in any shapes or sizes as reqired including one coat of primer and two coat of synthetic enamel paint to the entire steel surface all as specified and directed.
M & L for laying of dry, clean fine sand as in cushion or filling in trenches around underground cable, in ducts, inside sub station complete all as specified and directed.
Supplying and laying Precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. Make: Make: M/S MEHATAB TILES, Rani Shopping Centre, Bhanwar, Indore,(B) M/S NAVYA TILES, 68, NEHRU PARK, SARDARPUR,JODHPUR- 342003 Ph. 0291-2650094, 2627963(C) SAP PAVERS JODHPUR (D) SAGAR TILES SAHARANPUR (E) Star Tiles & Industries, Rama Devi, Kanpur
Burning of run lead 450mm joint in position including removing old lead for store and making new run lead joint with new lead and spun yarn etc complete all as specified and directed
Supply and fix in replacement of automatic RYB phase sequence corrector in sheet metal enclosure having current rating 200 Ams complete all as specified and directed. Make:Techno power model No:200a APSC or equivalent in L&T/Siemens/ABB
Supply and fix in replacement of automatic RYB phase sequence corrector in sheet metal enclosure having current rating 150 Ams complete all as specified and directed. Make:Techno power model No:150a APSC or equivalent in L&T/Siemens/ABB
Supply and fix in replacement of digital soft starter suitable for 50 HP ,3 phase,415 Volt with comprehansive motor protection,programmable overload protection ,built-in RTD & Thermister inputs with constant current adaptive accelaration & de-accelaration for smooth start and stop operation of motor Make:-L&T Cat No: EMX3-0053B-411 or equivalent in Crompton Greaves/Siemens/ABB/Schneider.
Supply and fix in replacement Automatic transfer switch, 4 pole 415 Volt 50 HZ , 100 Amp in SS enclosure with Automatic/manual with complete protection complete all as specified and directed Make Havells /INDO ASIAN/L&T
S&F GI earth strip 32X6 mm fixed to wall, on battens, or recess or chases or buried in found, complete all as specified and as directed .
S & F of change over switch with advanced neutral, ON LOAD, 63 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including operating handle conforming to IS:13947 (Part-3) complete all as specified and directed. Make : L&T/ Havells / HPL/ C&S
ROHIT ENTERPRISES
M/s Ravi Traders
M/S Ritu Tandon
M/S MUKESH AGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .