Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical DHURWA RANCHI | RANCHI | JHARKHAND | 829205 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical HOUSE NO 105 PARWEZ COLONY WARD NO 05 KISHUNPUR BUTI BUTI SADAR RANCHI JHARKHAND 835217 | RANCHI | RANCHI | JHARKHAND | 835217 | Admitted-Fee/PreQual/Technical |
Tender Value
₹6.3 L
EMD Value
₹12,700
Closing Date
25 Nov 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, RMC
RMC, RANCHI
Renovation work of Samudaik Bhawan for ward near office Sakhu Maidan under ward No-41
2026_UDD_121142_2
361/ENG 2026
Open Tender
Civil Works
Works
45 days
AS PER NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹12,700
26 Nov 2026
19 Nov 2026
26 Nov 2026
19 Nov 2026
25 Nov 2026
19 Nov 2026
180 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Labour for cleaning the work site before and after work etc. | |||||
| 1.01 | Dismantling old plaster and pointing in cement or lime and raking out jointd to 15mm -do-. | 213.66 | M3 | 33.81 | ₹7,223.84 |
| 2 | Dismantling PCC or lime concretework-do-. | 1.33 | M3 | 1,505.4 | ₹2,002.18 |
| 3 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level | 13.85 | m3 | 6,033 | ₹83,557.05 |
| 4 | Providing 12mm Thick cement plaster(1:4)-do- | 84.49 | m2 | 262.11 | ₹22,145.67 |
| 5 | Supplying .fitting and fixing MS Grill Made with M.S Grills made of 20 x 60 mm M.S Flats or 16 mm M.S Square bars fitted on 25 x25x6 mm M.S Angle frame-do-(when steel steel is not supplied department) | 903 | kg | 87.19 | ₹78,732.57 |
| 6 | Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. | 19.52 | M2 | 101 | ₹1,971.52 |
| 7 | Finishing wall with Premium Acrylic smooth exterior paint with silicone additives of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 90 litre/10sqm) | 169.23 | M2 | 134.74 | ₹22,802.63 |
| 8 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface toremove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready touse, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (Product Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°CTensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370. (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured."" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured(e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years." | 129.37 | m2 | 667.61 | ₹86,368.71 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers | 14.2 | m2 | 500 | ₹7,100 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
Tendernotice_2.pdf
PDF • 1.81 MB
BOQ_163940.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .