| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 CrAdmitted-Finance M 13 S S HARMU HOUSING COLONY PS ARGORA PO DORANDA RANCHI JHARKHAND 834002 | RANCHI | JHARKHAND | 834002 | ₹9.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.5 Cr+₹17.2 L (1.85%)Admitted-Finance ALAKPURI NEAR DURGA MANDIR DIST GIRIDIH | GIRIDIH | JHARKHAND | 815301 | ₹9.5 Cr+₹17.2 L (1.85%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Rejected-Technical 178 SHIVPURI COLONY CHAS BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | - | - | Rejected-Technical NON RESPONSIVE |
| Sl No | Description | Qty | Unit | M/S MANOJ KUMAR PANDEY L1 | Mahadeva Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. | 2,202.45 | CUM | 230 ₹5,06,563.96 | 153.54 ₹3,38,164.48 Lowest |
| 2.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B). | 1,294.98 | CUM | 25 ₹32,374.58 | 15.69 ₹20,318.28 Lowest |
| 3.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 1,343.05 | CUM | 55 ₹73,867.92 Lowest | 55.9 ₹75,076.66 |
| 4.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting withing a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 1,111.73 | CUM | 128 ₹1,42,301.95 Lowest | 130.34 ₹1,44,903.41 |
| 5.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 407.62 | CUM | 449 ₹1,83,019.14 Lowest | 457.14 ₹1,86,337.12 |
| 6.00 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 1,459.79 | SQM | 356 ₹5,19,686.31 Lowest | 362.81 ₹5,29,627.5 |
| 7.00 | Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. | 27.54 | SQM | 348 ₹9,583.92 Lowest | 354.59 ₹9,765.41 |
| 8.00 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two laters, bottom layer 19mm thick (1:2:4) with 12mm to 6mm size graded stone chips and top layer 6mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l. | 80.27 | SQM | 337 ₹27,050.99 Lowest | 343.61 ₹27,581.57 |
| 9.00 | Supplying chemical emulsion in sealed containers including delivery as specified (chlorpyriphos/ lindane emulsifiable concentrate of 20%) | 515 | Litre | 192 ₹98,880 Lowest | 195.36 ₹1,00,610.4 |
| 10.00 | Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. | 234.62 | CUM | 5,475 ₹12,84,528.08 Lowest | 5,576.22 ₹13,08,276.01 |
Tender Value
₹8.6 Cr
EMD Value
₹8.6 L
Closing Date
8 Jun 2022, 5:00 pmClosed
Nodal Officer
e Procurement Cell,BCD,Jharkhand,Ranchi
Construction of SDO Office Building at Chas, Bokaro, Jharkhand
2022_BCD_58733_1
BCD/ Bokaro/04/2022-23
Open Tender
Civil Works - Buildings
Item Rate
335 days
Chas
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE,BCD,Building Division,Bokaro
₹8.6 L
22 Jul 2022
25 May 2022
10 Jun 2022
25 May 2022
8 Jun 2022
25 May 2022
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B).
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting withing a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two laters, bottom layer 19mm thick (1:2:4) with 12mm to 6mm size graded stone chips and top layer 6mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l.
Supplying chemical emulsion in sealed containers including delivery as specified (chlorpyriphos/ lindane emulsifiable concentrate of 20%)
Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75B brick work in CM (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials. raking out joints yo 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75 A brick work in C.M.(1 :6) in Superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I.
Providing designation 100A brickwork with fly ash lime brick (FLAG) confirming to IS:12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/|.
Second Floor quanitity
Terrace Floor
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level
1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 Cement: 2 coarse sand(Zone III): 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 Cement: 3 coarse sand(Zone III): 6 graded stone aggregate 20 mm nominal size)
1:3:6 (1 Cement: 3 coarse sand(Zone III): 6 graded stone aggregate 40 mm nominal size)
1:4:8 (1 Cement: 4 coarse sand(Zone III): 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintel, Beam,and bress, including setting in cement morter 1:3 ( 1 Cement: 3 coarse sand) cost of required centering and shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 Cement: 1.5 coarse sand(Zone III): 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level.
1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return wall, wall (any thickness ) including attached pilasters, columns, piers abutments, pillars, posts, struts, butttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. up floor five level, excluding the cost of centering, shuttering and finishing:
1:1½:3 (1 Cement: 1½ coarse sand(Zone III): 3 graded stone aggregate 20 mm nominal size)
Providing and fixing at or near ground level precast cement in kerbs, edgings etc as per approved pattern and setting in postion with cement mortar 1:3 ( 1 cement: 3 coarse send ) , including the cost of required centering , shuttering complete 1:1.5:3 ( 1 cement: 1.5 coarse send (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, butterses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts ets. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15'' landing, balconies, shelver, chajjas , lintels, bands, plan window sills, staircases and spiral stair case above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick.
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs,(excluding landings) except spiral-staircasess.
Weather shade,Chajjas, corbels etc. including edges
Providing TOR steel reinforcement of 8mm, 10mm , 12mm , 16mm dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel)
(a) 8 mm (TMT coil Fe 500)
(b) 10 mm (TMT coil Fe 500)
(c) 12 mm (TMT coil Fe 500)
(d)16 mm (TMT coil Fe 500)
Providing TOR steel reinforcement of 20mm, 25mm , 28mm , 32mm dia rods or bars as per approved design and drawing excluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel)
(e)20mm (TMT coil Fe 500)
(f)25 mm (TMT coil Fe 500)
Supplying, fitting, and fixing 250 x 20 x 6mm L-type M.S. clamp properly fishtailed, including making holes and setting the same in 375x125x75mm. Cement concrete block ('1 .2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile B
Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting, and fixing M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing , properly fabricated with joints continuous fillet welded and finished, carriage of grill to work site, hoisting as per building speficiation and direction of E/I. (where material is not supplied by the deppt.)
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
Supplying,fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20X'10X2 mm. at 100mm. Centres and braced with M.S. flat diagonals 20 X 3mm, with top and bottom rails of T. iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification arrd direction E/|.
Supplying, fitting and fixing fully glazed steel door, winodws or ventilations of standard rolled 'Z' mullion steel sections and size as per IS - 1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with aluminium beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in postion in all storys and taxes all complete as per building specification and direction of E/I.
Supplying and fixing rolling shutters of approved make made of required size M.S. laths,m interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454-Part 1 and M.S. top cover of required thrickness for rolling shuttrs
Supplying, fitting and fixing 20 guage GCI sheet gate fitted on M.S> angle frame of size 60X60X6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in PCC (1:2;4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Supplying,fitting and fixing M.S. grill gate with M.S. grills made of 20xGmm M S. flats or 16mm. M.S. square bars fitted on25x25x 6mm. M.S. Angle frame -do- (when steel is not supplied by the deptt.).
Providing and fixing stainless steel (grade 304) railing made of Hollow tubes, channels, plates etc,. Including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessry stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterners etc,.)
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l
Supplying, fitting and fixing 35mm thick solid core type non decorative single leaf flush shutters in doors and windows with block board core blended with high quality pehnol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1sq.mm in all types of flush doors (cost of glass excluded) (overall area of door shutter to be measured)
Rectangular or square
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or deyed to required colour or shade with nuts and screws etc. complete
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete
Twin rubber stopper
Providing and fixing PVC igid form sheet 1mm thick on existing door shutters (bthroom and WC doors) using synthetic rubber based adhesive
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge
With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
(a)Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral coresandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structuraland weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Area of slab over 0.50 sqm)
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. (8mm thick)
Granite of any colour and shade
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified glazed ceramic floor tiles 300x300m or more (thickness to be specified by manufacture) of 1st quality conforming to IS:15622 with approved make in colours white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments, etc all complete.
Providing and laying Doublecharge vitrifed floor tiles in differents size (thickness to be i specrfred by lhe maiirifacturer) with water absorption less than 0.08% and conformrng to lS 15622 / SO 13006 of approved make, in all cotours and I shacjes laid on 20mrn tlrick'cement mortar 1 4 (1 cement:4 coarse Isancl) lointing witir grey cement slurry @ 3.3 kg/ sqm including I grouting tiie joints v/ith v/hite cement and matching pigments etc., I cornplete Size of l-ile 600x600 mm
Chequered precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) - light shade using white cement
Extra for flooring works for each consecutive floors above first floor complete as per direction of E/I
(sum of area of all floorings used) for Eg.
All 2nd Floor
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curring, taxes and royalty all complete as per building specification and direction of E/l.
Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 12mm Thick cement plaster (1:6) with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing 6mm Thick cement plaster (1:4) in ceiling with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I
Second Floor
Third Floor
Making 6x6mm grooves in plaster surface over walls truely horizontal or vertical as specified. at regular intervals, at all heights including cleaning, finishing, scaffoding and curing wth all leads and lifts of water all complete as per building specification and direction of E/|
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building speicification and direction of E/I.
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding, curing and taxes all complete as per bldg.specification and the direction of E/I.
Providing & laying water proofing treatment in sunken portion of WCs, bathrooms etc. by applying cement slurry mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours (b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry.
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n'ieasurernent tite entire treated surface will be measured."
(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified, reatiy to-use, flexible cementttious material right angle to the '1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl." Alte r three days of drying the 2nd coat, therainwater ouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal<age from soffit and if found necessary rectification lo be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectifcation to be done as per satrsfaction of E/C protected from damage before screed over it. Watqr proofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolmer, Part B Specially graded cementitious powder - Density 1.6 l.rg/l (mixcd density) at +27oC Tensile Strength - 2 lllmm2 after 28 clays (with Fibre cloth) (According to ASTM D 2370)Prillcut Bond Streric;tl-r '-2 I'J/mm2 (concrete lajlqry) (Aqgcrdlglq ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.'15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Clot (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( '1:120) towards tlre rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mrn gap betuieen the panel joint. lntegralwater proofing admixture conforming to lS 2645 @ of 100 ml per bag of of cement to be added in the scree d concrete(pard separately for thts ltems).-All corners shall be charrmfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouih to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose ofrreasurement the entire treated surface will be measured."
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc Warranty for Five years.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cementn Concrete M20(1:'1.5:3) r'naintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Provrding and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge (with 18% GST).Brand:-SikaPolysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Providign and applying Plaster of Paris Putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per buiiding specification and drrection of E/i.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required, scaffolding, washing of floors, and taxes, all complete as per building specifications and direction of E/I
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :
New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
White washing three coats over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing, of floors and taxes all complete as per building specification and direction of E/l.
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surfaces including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes, all complete as per building specifications and direction of E/I
Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including cleaning the surface after removing dirt, scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specifcation and direction of E/I.
Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all comple as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/l.
Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Single push fit coupler 110 mm. dia.
Bend 87.5 degree (110x110x110mm)
Shoe (Plain) (110mm shoe)
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less thaN 440 grams.
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant atOMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. (450 mm dia. R.C.C. pipe metre)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Labour for laying, fitting and fixing NP2 R.C.C. spu pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leak, proof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complete as per specification and direction of E/I. 150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.
Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I. 150mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
Bricks
Coarse Sand
Stone Chips
Stone Metal
Earth
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I.
Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.
Horizontal - 32mm dia
Vertical - 25 mm dia
Providing and fixing 15mm size C.P. brass pillar cock (Weight not less than 350 gms.) C.I. body brass spindle pillar cock of approved quality as per specification and direction of Engineer-in-charge. C.I. body brass spindle
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l (A) BRASS STOP COCK
(a) 15 mm dia wt not less than 300 gms
(b) 20 mm dia wt not less than 400 gms
Cutting chhajja or corince for laying G.I. / C.P.V.C pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I.
Making holes in walls for laying G.I. / C.P.V.C pipe and restoring the same after pipe laying as per specification and direction of E/I.
125 mm thick wall
250 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 600mm x 450mm
Glass shel with C.P. brass rail - 450mm x 125mm
C.P. brass towel rail 20mm x 600mm with bracket container
C.P. brass soap dish container medium quality with screw and hinges etc.
C.P. bras liquid soap container
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I.
580mm long
With 10 Liter Low Level P.V.C. cistern
Supplying, fitting and fixing 40mm high viterous white glazed earthen E.W.C. with 'p' trap of Parry/hindustan or any other approved I.S.S. make including supplying and fixing 15 liters C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C. alkathene pipw 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead o commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approvd paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
With 'P' trap - 10 ltr. Low level PVC cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan "Parry" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.
Flat back or standing corner (600mmx 350mm)
Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. For classification of soil item - A
Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I. 150mm dia R.C.C. spun pipe
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Supplying materials and labours for fixing 20 mm dia MS bar steps in steining well of 0.3 m interval and staggred in (1:2:4) cement concrete including scaffolding and curing etc all complete job as per specification and direction of E/l
Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in Carge.
(a) 15 mm nominal outer dia pipes
(b) 20 mm nominal outer dia pipes
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee with door - 110x110x110 mm
Single tee without door - 110x110x110 mm
Bend 87.5° - 110mm
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink without drain board
610x460 mm bowl depth 200 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing PTMT grating of approved quality and colour.
C.P. Gratings
Circular type - 100mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
Supplying the follwing bathroom fittings all complete (VIP)
Angular stop cock (Long Thread)
Pillar cock (Long neck)
Telephone shower with flexible pipe/ Health Façade
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade ( Size 0.45x0.900x 9= 3.645
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage complete (by mechanical transport upto 5Km lead) (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage complete (by mechanical transport upto 5Km lead) (manure measured in stacks will be reduced by 8% for payment):
Screened through sieve of I.S. designation 16mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the Ground.
Spreading of sludge, dump manure or/and good earth in required thickness as per direction of officer-in-charge (Cost of sludge, dump manure or/and good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the officer-in-charge.
In rows 5 cm apart in both direction
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm. efilling the excavated earth after breadking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, with in a lead of 50m lift up to 1.5 m complete (cost of sludge, manure of extra earth to be paid for separately).
Around Outer & Inner Length of Bondary Wall
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately):
Holes 1.2 m dia and 1.2 m deep.
Holes 90 cm dia, and 90 cm deep.
Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.
Trees for 300 No. (4-8 & 5-6 year Slow & Fast growing group) ( 18 Manth Per Tree 175x 18 = 11484.00)
Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete: With common burnt clay F.P.S. (non modular) bricks of class designation 5
TREES
Alstonia scholaris of plants height 150-165 cm. in bag of plants size 25 cm
Azadirachta indica ( Neem ) of plants height 120-130cm in big polybag of plants size 25 cm
Cassia fistula (Amaltash) of plants height 120-135 cm. in big poly bags of plants size 25 cm
Delonix regia (Gulmohar) of plants height 150-165 cm. in big poly bags of plants size 25 c
Ficus benjamina (green) of plants height 120-135 cm. with 6-8 branches and lush green foliage in gunny bags of plants size 25 cm
Fishtail palm of plants ht. 150-180 cm bottom girth 15-20 cm well developed in big poly bags of plants size 25 cm
Foxtail palm of plants ht. 120-150 cm bottom girth 15-20 cm well developed in big poly bags of plants size 25 cm
Jacaranda mimosifolia of plants height 150-165 cm. in big poly bags of plants size 25 cm
Mangifera indica (Mango-grafted ) of plants height 60-75 cm. in big poly bag of plants size 25 cm
Plumeria alba of plants height 120-135 cm. with 2-3 branches in bags of plants size 30 cm
Polyalthia longifolia (Ashok) of plants height 150-165 cm. in earthen pots of plants size 25 cm
Eugenia jambolana (Jamun) of plants height 150-165 cm. in big poly bags of plants size 25 cm
OKNAMENTAL PLANTS
Providing Plant Dahlia single in different colour with fresh & healthy foliage well developed with 6 to 8 half blooming buds in 20 cm Earthen Pot/Plastic Pot.
Providing Plant Daisy well developed with fresh & healthy foliage in full bloom in 20 cm Earthen Pot/Plastic Pot.
Providing Plant Salvia red Hybrid dwarf variety having 15 to 23 cm ht., specimen 6 plants with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/ Nand
Providing Plant Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot,
Washingtonia filifera palm well developed 90 to 105 cm ht. plant having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot
SHRUBS
Supply and stacking of plant Cassia biflora of height 45-60 cm. in earthen pots of size 20 cm
Supply and stacking of plant Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm
Supply and stacking of plant Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm
Supply and stacking of plant Hibiscus variegated of height 60-75 cm. with healthy variegated foliage in earthen pots size 25 cm
CREEPER PLANTS
Allamanda cathartica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan, Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots.
Quisqualis indica plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots
FOLIAGE/SHADE LOVING PLANTS
Providing of Areca Palm plant, having ht. 1.20 m to 1.50 m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Areca palm plant, having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Croton Golden plant, having ht. 45 cm to 60 cm with 2 to 3 branches, well developed, fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot.
Providing of Diffenbachia Tropicsnow plant, having ht. 60 cm & above with 8 - 10 leaves, well developed, fresh & healthy in 25 cm size of Earthen pot / Plastic pot.
Providing of Draceana Song of India Green plant (three in one), having ht. 30 cm, well developed, fresh & healthy, lush green foliage from bottom to top in 20 cm size of Earthen pot / Plastic pot.
Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
GroupC
Twin Control Point Wiring in PVC Conduit, with Modular type Switch (Used for stair case light):- Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc as required.
Power Plug Wiring in PVC conduit (2x4 sq. mm)(used for power circuit):- Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sqmm+ 1x1.5 sqmm earth wire
2x2.5 Sqmm+ 1x2.5 sqmm earth wire
2x2.5 Sqmm + 1x2.5 sqmm earth wire (For HPSV
2 x 6.0 sq.mm. + 1 x 6.0 sq.mm. earth wire
4x6 Sqmm + 2x6 sqmm earth wire
4x10 Sqmm + 2x6 sqmm earth wire
4x 16.0 sq.mm. +2 x 16.0 sq.mm. earth wire
Wiring in existing conduit- Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
22x 1.5 sq.mm.
Telephone Wiring in Existing Conduit:- Supplying and drawing following pair,0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required
TV Wiring in Existing Conduit:-TV Cable in Existing Conduit: Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required,
S/F PVC Conduit ( for Data. and Telephone):-Supplying and fixing of following sizes of PVC conduit alongwith the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required for Tele, RJ45 Cat 6 data outlet for computer network.
S/F Modular type Switch / Socket:-Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.
5/6 amps,one way switch (for Existing Switch Board)
15/16 amps,one way switch (for Existing Switch Board)
5/6 amps, 3 pin socket outlet (for Existing Switch Board)
Telephone socket outlet
TV antenna socket outlet
S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Modualr type blanking plate Supplying and fixing modular Dlanking plate on the existing modular plate and switch box excluding modular plate as required
S/F Modular Boxes, base & cover plate (Used for TV and Tele.) :- Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (78 mm x 78 mm x 45 mm)
Supply and Fixing Light Plug Point with Modular Type Accessories ( Used for computer point):-Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
Supply and Fixing Light Plug Point with Modular Type Accessories (Used for power ):-Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
S/F Ceiling Rose (for fan ):- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required.
S/F Call bell buzzer |Supplying and fixing call bell/buzzer suitable for D.C./A.C. single phase, 230 volts complete as required.
ITC fluorescent fitting directly on surface (for tube light) :-installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper cond.
ITC Ceiling Fan:-Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
ITC Exhaust Fan/Wall Fan upto 450 mm sweep :- Installation of exhaust fan / Wall Fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR).
4 Ways (4+12 ways) double door
6 Ways (4+18 ways) double door
8 way (4 + 24), Double door, Horizontal type
S/F '6' series, S.P. MCB- Supplying and fixing 6 amps to rating, 240 volts, '8' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required
1b/52 amps, Single pole "8" series
S/F 'C' series SP MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32 Amps, SPN
40A TPN MCB
50/63A TPN MCB
COPPER EARTH PLATE ELECTRODE:- Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or cock and salt) complete etc. as required.(2 Nos. for Main Panel,2 Nos. for D.G Set, 2 Nos for transformer, 2 Nos. Lighting Conductor,2 Nos. for UPS )
S/L 8 SWG Copper wire in ground in ground (for main panel and APFC panel) :- S/L 8 SWG Copper. wire in ground :- Supplying and laying 8 SWG Copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.
S/L 8 SWG copper wire:- Supply and tixing 8 SWG cpper wire at 0.50 metere below ground level for coductor earth electrode including soldering etc. as required.
Providing and Fixing G.I Lightning Conductor Finial : P/F of lighting conductor finial, made of 25mm dia 300mm long, G.I tube, having single prong at top, with 85mm dia 3mm thick Copper base plate including holes etc. complete as required.
Reverting sweating and soldering lighting conductor tape : Reverting sweating and soldering of copper/G.I. tape (with another copper/G.i. tape,base of the finial or any other metallic object) as required.
P/ F G.I. Lightning conductor tape in horizontal run :- Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (horizontal run).
P/ F G.I Lightning conductor tape in vertical run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (vertical run).
|MV cable laying upto 400 sq.mm. in ground lying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV &rade of size not exceeding 120 sq.mm. but not exceeding 400 sq.mm. direct in Eround including excavation, sand cushioning, protective covering and refilling the trench etc. as required
MV cable laying upto 25 sq.mm. in ground without sand and cover laying one number PVC insulated and PVC insulated and PVC sheathed/XLPE powe |cable of 1.1 kV grade of size not exceeding 25 sq.mm. direct in ground including excavation, and refilling the trench etc. as required. (But excluding sand cushioning and protective covering
Providing and fixing of XLPE, PVC, aluminium armoured cable of grade 1.1KV as per S7908 (Part-1) 1988, etc. as required. Make:- Havells / Finolex / PolycaD
2 Core 10 mm 1.1kV 1 R from External Panel to Main Gate Light.
3.5 Core 50 mm 1.1kv
3.5 Core 185 Sq. mm. 1.1 Kv.
1.1 KV Cable End Termination:- Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE AI. Ar. Cable of 1.1 KV grade as required.
3.5 Core 50 Sq. mm.
3.5 Core 185 Sq. mm.
Supplying and fixing of 9/10 Watt LED Bulb
Supplying and fixing of LED round Downlight 12 w
Supplying and fixing of LED Bollard fitting with Cylindrical shape 8/9 Wat
Supplying and fixing of LED Bollard fitting with Cylindrical shape 8/9 Wat
Supplying and fixing LED Batten (20/22W)
Supply fitting fixing of Bulk head fitting with 9/10 watt CFL/LED
Supply of LED Street light (45/48W)
Supply and installation of Ceiling fan 48" (1200mm)
Supply of 12" (300mm) metal exhaust fan
Supply, Installation, Testing and Commissioning of electric driven, horizontal type, single/multistage, end suction type, centrifugal pump of cast iron body, C.I impallers with carbon steel shaft & mechanical seal directely coupled with TEFC SQ cage foot mounted type induction motors suiitable for operation on 3 phase, 415 volts 50 Hz AC supply having flow rate of min 450 LPM and head of approx 40 mtrs complete in all respect as required or as directed by engineer incharge. (Terrace Pump)
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required
3 × 10 sq.mm.(aluminium)
Providing and fixing IS marked butterfly valve (PN 1.6) complete with companion flanges, bolts, nuts, rubber insetions etc.
80 mm diameter
100 mm diameter
Providing and fixing check valve (NRV) complete with companion flanges, bolts, nuts, rubber insetions etc.
80 mm diameter
100 mm diameter
Providing, laying, testing & commissioning of IS 1239 marked black M.S pipe including all fittings i.e bend, elbows, tees, flanges, reducing socket, nuts and bolts, gaskets etc fixed with welded / screwed joints. including necessary excavation, backfilling, removal of surplus soil etc. min. 1 mtr deep excavation and wrapping with anticorrosive treatement with 4 mm thick asphalt tape as per IS:10221, refilling the trench etc. OR fixed with screwed or welded joints, hanged with clamps, hanger supports, dash fasteners, bolts, nuts, rubber insertions etc including threading, cutting, welding, edge preparation, painting of approved colour over two coat of primer, cutting & making good the wall/ floor wherever required, complete as required or as directed by engineer incharge. Make:Tata/Nezone/Jindal
100 mm diameter
80 mm diameter
25 mm diameter
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : (Single headed Gunmetal)
Providing and fixing swinging, wall mounting type First Aid Hose Reel of approved quality and made from compresed steel sheet with dust cover, cast iron brackets including 30 m long, 19 mm nominal bore, high presure braided rubber hose as per IS:444 Type hose guide, PVC shut off nozzle with 6 mm outlet and 25 mm nominal bore gun metal inlet valve, bolts, nuts rubber insetion etc. painted in Fire red colour including cutting and making good the walls wherver required.
Providing and fixing in position 63 mm nominal bore and 15 m long synthetic fibre, CP fire hose pipe of approved make bearing IS: 636 -1988 type A mark and having TAC and MMD approved with a pair of 63 x 63 mm gun metal instantaneous type, heavy duty delivery hose coupling (conforming to IS: 903) bound and riveted to the hose pipe with copper rivets and copper wire complete.
Providing and fixing in position short SS brach pipe of approved quality with 63 mm male instatneous type inlet and 15 mm outlet nozzle complete conforming to IS : 903
Supplying, fixing, testing & commissioning of 1 set of 63mm two way instantaneous fire brigade connection (FBC) with inbuilt NRV comprising of SS and four SS instantaneous male inlet coupling confirming to IS:604 with plug and cap with chain as required with nut & bolts, washers, high pressure gasket as required.
Supplying, installation, testing and commissioning of duel tone electronic hooter / Flasher / Strobe suitable for wall mounted complete as required. Make:Tyco/Honeywell/Seimens/ Qutak/ Bosch
Supplying, installation, testing and commissioning of manual call box in suitable enclosure with arrangement to raise the alarm when the glass is manually broken complete as required. Make:Tyco/Honeywell/Seimens/Qutak/Bosch
Supplying, installation, testing and commissioning of microprocess base main fire alarm control panel with LCD Display lights. The panels shall have 240 volts AC power supply automatic Battery charger 24 Volts sealed lead acid maintenance free battries as complete with batteries, battery charger illuminated numeric digram complete as required. Make:Tyco/Honeywell/ Seimens/ Qutak/ Bosch
Supplying and fixing of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 25 mm
Supplying and fixing metal/PVC box / Circular (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Non Schedule
Providing, fixing, and installing, 8 passenger elevator, Lift well size - 1950(W) x 2525 (D), No. of Stops - 3, Openings-3, Ground Floor to 2nd Floor Height- 3.6 M, Clear Door Opening- 900mm, Speed of Lift - 1.M/s, Vision Panel, Automatic rescue device, etc., with all necessary features,WITH machine room, Stainless Steel Vandal proof Finish, all complete as per specification and instruction of Engineer in charge. The work also include all building/ structural works for supporting arrangement system, necessary scaffolding required for erection of the complete system, necessary wiring and installation of lighting for lift well and lift pit, providing ladder in the lift pit etc. as required complete. (Rate -1228813.56 + Add 16% ( CP+OH+W) = 1425423.73
Supplying installation, testing and commissioning of cubical type MV Panel made Out or 14 SWG sheet steel, totally enclosed IP-54 protection, free standing. floor Ounted dust and vermin proof, indoor type compartmentalZed powder coaled o dpproved shade after antirust treatment (with min seven tanks) suitable with busba erConnection with suitable size of copper lead/solid Aluminium strips, control circuits Dottom base channel of MS section not less than 100mmx50mmxQmm (thick), dtion shall be done in transportable section ,entire panel shall have a common eanh busbar at rear with 2 nos earth stud cable alleys, cable gland plates in wo hal Tequired as per single line diagram & specification enclossed with the following Switchgear
INCOMER:
315 Amp (36KA), manual.fixed, MCCB (2 Nos.I
CHANGE OVER:
315 Amp,4 POLE (1 Nos
1 Set phase indication lights (R, Y, B
No. Volit Meter (digital type) with inbuilt VSS & control fuses.
NO.Ammeter (digital type) with inbuilt ASS
AL. BUSBAR CHAMBER:
400 Amps. TP&N Aluminium bus bars (50 KA
OUT GOINGS:
4 pole MCB 63A,16 kA with fixed thermal magnetic setting.(5 NoS.)
4 pole MCB 40 A,16 kA with fixed thermal magnetic setting(12 NoS.
6/32 A,DP (S Nos.
Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42.
Pressure Gauge Assemble with Gate/Ball Valve
Air release Valve
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity)
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (3 Kg Capacity)
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity)
Add 12 % GST
Add 1% Labour Cess
Mahadeva Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_79141.xls
BOQ • 0.52 MB
SBD04SDOChasRetender.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .