| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹49.4 L+₹83,899.80 (1.73%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹52.5 L+₹3.9 L (8.00%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | Rejected-Technical NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | - | Rejected-Technical Not enlisted in c(i) category |
Tender Value
Refer Docs
EMD Value
₹99,960
Closing Date
6 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
SPL REPAIR OF BER COOLING APPLIANCE AND CERTAIN SANCTIONED WORKS AT AFTC AND AF STN JALAHALLI
2023_MES_630814_1
8857/E8
Open Tender
Electrical and Maintenance Works
Item Rate
151 days
Jalahallii
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹99,960
8 Feb 2024
9 Dec 2023
8 Jan 2024
9 Dec 2023
6 Jan 2024
23 Dec 2023
9 Dec 2023 - 16 Dec 2023
Amount
Taking down Chowkats or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames), complete all as specified & directed.
Material and labour pre-cast PCC 1:3:6 type C1 (20 mm graded crushed stone aggregate) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:4,, complete all as specified & directed.
Material and labour rendering 10 mm thick CM 1:6 on brick /concrete surfaces finsihed even and smooth without using extra cement, complete all as specified & directed..
Material and labour rendering 15 mm thick CM 1:4 on brick /concrete surfaces finsihed even and smooth without using extra cement, complete all as specified & directed.
Material and labour for one coat of 3mm thick wall putty on new and old wall surfaces prior to any type of treatment, surface finished even and smooth to receive painting finish , complete all as specified & directed.
Material and labour for prepration of new wall surfaces and applying two coats of anti reflective white GOO paint over a coat of primer , complete all as specified & directed.
Material and labour for preparation of new plastered wall surfaces of any description and applying two coats of cement base paint, complete all as specified & directed..
Material and labour for preparation of old surfaces of wall including scrapping down, smoke soot, efflorescence salts, trading oil and greasy spots etc by applying two coats of black GOO paint over a coat of primer , complete all as specified & directed..
Material and labour for preparation of old surfaces of ceiling including scrapping down, smoke soot, efflorescence salts trading oil and greasy spots etc and applying two coats of oil bound distemper , complete all as specified & directed..
Material and labour for 2mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors , complete all as specified & directed..
Supply and fix Inverter AC split unit Indoors and outdoor 5 star rated complete with smart inverter full filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 1.5 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, Active Carbon/ High density dust Filter complete including installation complete all as specified and directed. Make: Sumsung / LG/ HITACHI / Blue Star/ Carrier
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA complete all as specified and as directed. Make - V-Guard Model No VG 500 or equivalent in Microtek/ AE
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing, complete all as specified and directed,
Supply and fix metal clad 20 Amps single pole and neutral enclosure with 2pin and earth plug and socket complete with sheet steel enclosure and controlled with and including 1 No single pole MCB SP 20 Amps 'C' series , complete all as specified & directed. Make : Indo Asian/ Havells/ Legrand
Material and labour for 25 mm dia low density polyethylene pipes (LDPE) of pressure 6kg/sqcm fixed complete on walls, ceilings including all accessories for drain pipe, complete all as specified & directed.
Supply, installation & commissioning of water cooler stainless steel body, electric driven, single phase having storage and nominal cooling capacity of 80/40 ltrs including taking down existing unserviceable water cooler of any description and deposit to MES store, complete all as specified and directed. Make : Blue Star/ Voltas/ Hitachi. Note :- (a) The Contractor shall give a written guarantee of minimum two years from completion of work.
Material and labour for PVC pipe of size 32mm dia LDPE waste hose pipe fitted to water cooler, complete all as specified & directed...
Supply and fix inverter AC split unit Indoor and outdoor 5 star rating complete with smart inverter full filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 2 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and filter configuration with, active carbon/ high density dust filter including installation, complete all as specified and directed. Make: Sumsung / LG/ HITACHI / Blue Star/ Carrier.
Supply and fix voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA suitable for 2 TR split AC, complete all as specified and directed. Make :- V Guard/ Microtek/ AE
Material and labour for PVC hose connection pipe of 300 mm length both ends having brass coupling threaded for 15mm GI tubing of standard length, complete all as specified & directed.
Supply and laying of GI tubing medium grade 15 mm bore laid on floor/wall including all fittings such as bend,tee, union, elbow etc , complete all as specified & directed.
Supply and fix stop valve 15 mm dia, cast copper alloy chromium plated high pressure with crutch or butterfly handle screwed both ends for GI pipe/fittings inlcuding removing old unserviceable, complete all as specified and directed.
Cutting exisiting steel tubing / PVC pipe for alterations or additions for 25/32mm bore pipe, complete all as specified & directed.
Dismantling and taking down old unservicable split AC unit indoor and outdoor of any capacity and description and connected fittings including old unservicable voltage stablizers of any capacity and description and depositing the same in store yard of AGE E/M, complete all as specified & directed.
Material and labour for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC and all accessories fixed to wall/floors along with 4 sqmm PVC conduit insulated unsheathed copper conductor FRLS multi stranded cable 1100V grade as earth continuity and connected to common earth dolly , complete all as specified & directed. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through and incl suitable size surface PVC Conduit and all accessories fixed to wall/floors along with 6 sqmm surface PVC insulated unsheathed copper conductor FRLS multi stranded cable 1100V grade as earth continuity and connected to common earth dolly , complete all as specified & directed. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Material and labour for wiring for circuit complete sub main wiring with 2 X2.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed to surface of wall/roof/ceiling etc and incl 2.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100 volts grade multi stranded copper conductor cable as earth continuity conductor , complete all as specified & directed. Note :- (a) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (b) 2 runs of 2.50 sqmm singnal core cable and 01 run of 2.50 sqmm for erth wire shall be measured an one length. Make:- Havells/ Polycab/ Plaza.
Supply, Installation, testing, and commissioning of 11KV extensible Ring-Main-Unit, Outdoor type with IP65 or higher fabrication (ensuring outdoor protection to complete RMU, including cable-boxes), SF6 gas insulated compact switchgear, comprising arrangement of 02 load break switches for incoming with suitable mechanical interlocking between two incomers and 02 VCB for outgoing, all of rating 630Amp, and Bus PT metering Module, cable termination from front, having short-circuit withstand capacity of 20KA/3sec, permanently enclosed in a tank made by sealing non-magnetic / non-ferritic stainless steel sheets, to provide IP67 degree of Protection to live parts and Internal Arc protection (IAC 20kA/1-sec for tank), duly filled with SF6 gas with leakage rate less than 0.1% and partial discharge tested as per IEC 62271-200, complete with all aceesories as described below and coupling busbars for bus-coupling of two RMUs where necessary, to meet the desired configuration. The earthing busbar shall be of aluminium and provided in each cable box & through out the length of the switchgear , complete all as specified & directed.and comprising of the under mentioned specifications:- (Make: SCHNEIDER / ABB / SIEMENS). (a) Each Load Break Switch module shall comprise of: (i) Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism, suitable to break upto 630 Amp of rated current, along with associated earthing switch of matching capacity. (ii) True position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel (iii) “Live Cable “Indicating LEDs energized through Capacitive Voltage Dividers shall be permanently available on the front facia, without requiring any external instrumentation. Whereas the cable bushings shall be enclosed inside hinged door cable-box interlocked with respective Earthing switches. (iv) Right Angle terminal protector boots for covering the cable termination.
(b) Each Vacuum Circuit Breaker Unit Module shall comprise of: (i) Manual operated, fixed-type 11kV Vacuum circuit breaker suitable for breaking short circuit current upto 20kA having two position double spring charging mechanism. (ii) In-series, Three position disconnector/earthing switch on downstream side of vacuum circuit-breaker (iii) Mechanically latched ON/OFF Push Buttons along with True position mechanical indication of Vacuum Circuit Breaker position (ON/OFF) and Disconnector position (ON/OFF/EARTH) shall be available on the front facia of the panel (iv) “Live Cable “Indicating LEDs energized through Capacitive Voltage Dividers shall be permanently available on the front facia, without requiring any external instrumentation. Whereas the cable bushings shall be enclosed inside hinged door cable-box interlocked with respective Earthing switches. (v) Right Angle terminal protector boots for covering the cable termination. (vi) Integrated 3 O/C + 1 E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also Relay shall record minimum 5 fault records with time stamping. (vii) Set of 03 Nos Ring Core Epoxy-cast Protection CTs having suitable ratio 5P10 burden 2.5VA, directly mounted on trifurcated but sleeved portion of cable terminated. Note for item No. 28 (a) The quoted unit rates deemed to be inclusive of the following:- (b) The tenderer is advised to visit the site before quoting the tender. (c) The cost of electrical and mechanical interlocking between VCBs as per site conditions shall be deemed to included in the quoted rate. (d) PCC foundation of required size and shape for installation of the Panel on ground as per manufacturers recommendations. (e) Drawings of VCB & RMU shall to be approved by the Accepting Officer before placing order to the manufacturer by the contractors.
(f) All other makes of components pertains to VCB & RMU not specified in the tender documents shall be of reputed make as recommended by the OEM only. (g) Pre - commissioning test shall be carried out by the SEI/EI. (h) Disconnecting the connection from the existing system wherever applicable and connecting incoming and outgoing HT cable with RMU. However, Cable end termination joints will be measured and paid separately under relevant item of the Schedule 'A' BOQ. (j) The contractor shall intimate date of testing of equipments at site before installations. Copies of all documents of routine and type of test certificate of the equipments from the manufacturer shall be furnished to the Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil, complete all as specified & directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm, complete all as specified & directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified & directed.
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. Then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Supplying & laying un-reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm laid over cable for protection,complete all as specified & directed.
Supply, laying, testing and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HTUG), 11000 volts grade with stranded aluminium conductor of size 3 core 120 Sqmm ( Earthed cable) ,complete all as specified & directed.. Make: Havells/ Polycab/RPG Asian
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm and testing after jointing including taking out old unserviceable joint kit complete all as specified and as directed. Make: Raychem/ Denson/ 3 M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm and testing after jointing including taking out old unserviceable joint kit complete all as specified and as directed.Make: Raychem/ Denson/ 3 M
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down old existing earthing of any description, complete all as specified & directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO. Note: The quoted rate shall deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report shall be submitted to Garrison Engineer with recommendations of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate. (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.B52
(iii) Rate of earth energizer compound of 02 bags of 25 Kg and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate. (iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. (vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately). (vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to GE duly signed by all concerned. (viii) Earth resistance tester shall be provided by the contractor. Tester shall be calibrated from authorised company/ lab only. (ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify the same at no extra cost to Govt till desired result is mainained. (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor for the guarantee period. (xiv) The electrode shall carry manufacturer's name . (xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
Material and labour for Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down old existing complete all as specified & directed. NOTE : All Joints shall be jointed by Exothermic Welding or Brazing.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down old unserviceable cover of any description, complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Taking down aluminum/copper point wiring including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete including of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc and making good the disturbed surfaces of wall, floor, ceiling and painting 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean, complete all as specified and directed.
Material and labour point wiring for one light point/ fan/bell point controlled by one switch with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable FRLS 1100V grade as earth continuity conductor & connecting to common earth dolly complete all as specified and directed. Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast B60
All as per item No. 41 here in before but for one switch socket outlet 3 pin 5 Amps on independent board, complete all as specified and directed.
All as per item No. 41 here in before but for one 3 pin socket outlet 5 Amp on the same board, complete all as specified and directed.
All as per Sl No 41 above but wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm FRLS copper cable for earth continuity conductor controlled by one 15A switch socket independently, complete all as specified and directed.
All as per Sl No 41 above but wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper cable FRLS for earth continuity conductor controlled by AC point/power equipment, complete all as specified and directed.
Supply and fix modular switch 1 way 6 Amp.one module, complete all as specified and directed. Make : Legrand , Anchor , Crabtree
Supply and fix modular switch 1 way 16 Amp.one module, complete all as specified and directed. Make : Legrand , Anchor , Crabtree
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module. complete all as specified and directed.. Make : Legrand , Anchor , Crabtree
Supply and fix modular Socket, 6/16A - 3/5 pin combined 2 module,complete all as specified and directed. Make : Legrand , Anchor , Crabtree
Supply and fixing modular fan regulator 120 W,2 module for ceiling fan, complete all as specified and directed. Make : Havells / Anchor/ Crabtree.
Supply and fixing ceiling rose 3 terminals PVC/ Polycarbonate body, complete all as specified and directed.
Supply and Fixing of 4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned, complete all as specified and directed. Make Philips/Bajaj / Wipro/ Crompton.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 sqmm drawn through in and incl suitable size surface PVC Conduit and all accessories fixed to wall/floors along with 10 sqmm surface PVC insulated unsheathed FRLS copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly, complete all as specified and directed.. Note: (a) 2 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and fixing MCCB up to 100 Amps 16 KA, Four Pole 415 volts, 50 HZ complete all as specified and as directed. Make: Indo-Asian Model: Optium cat Pt No: 830022/ Legrand/ L&T
Supply and fixing 32 Amp MCB SPN rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of current carrying capacity in the MCB DB with connection testing and commissioning complete all as specified and as directed. Make Indo Asian/ Havells/ Legrand
Supply and fixing MCB DB(distibution board) 8 way SPN(single pole and neutral) single phase made of sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection , complete all as specified and directed.. Make : Indoasian / Legrand / L&T
Material and labour for sheet metal enclosure with single pole and neutral with a two pin and earth plug and socket,with one single pole MCB of 16Amp cap 'C' curve, complete all as specified and directed. Make Indo Asian/ Havells/ Legrand
Supply & Fixing Single pole and neutral enclosure with a two pin and earth plug & socket Modular type with one single pole MCB 20 Amps, fixed for AC/ other equipment on wall and making all connections complete all as specified and directed. Make : Havells / standard / Indo Asian
Supply and fixing MCB SP 5 to 32 Amp 240V, 10 KA 'B' curve miniature circuit breaker (MCB) and current carrying capacity 5 to 32 Amp, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.Make Indo Asian/ Havells/ Legrand
Supply and fixing TPN MCB DB(distibution board) Double Door 4 Way, TPN IP:54 protection, isolated neutral bar, Mechanical impect strength three phase, cement spill protector, 415 volts and connection complete all as specified and as directed. Make : Indoasian / Legrand/ L&T
Supply and fixing of Powder coated aluminium frame work for partition with one or more rebates incl Joining cleats,hooks, hangers, beadings, rubber gaskets etc, minimum thickness of powder coating 50 micron and fixed in position for making bed curtains, complete all as specified and directed.
Supply and fixing prelaminated particle board 18/19mm thick one side decorative face of exterior grade as in cup board shutters, shelves and as in partition , complete all as specified and directed.
Supply & fixing only 12mm thick Veneered particle board, solid core, exterior grade, with decorative face veneers for both faces,complete all as specified and directed.
Supply and fix 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane , complete all as specified and directed.
Material and labour for complete removal of existing treatment, using mechanical sander with internal dust extraction system ,preparation of old surfaces of wall, priming surface with chalk whitening and applying acrylic distemper (1st quality) ready mix to required finishing having VOC contents less than 50 gms/litre of approved manufacturer, of required shade and colour, complete all as specified and directed.
Material and labour for 10mm thick coloured vitrified tiles (Square/rectangular ) polished ,area of each tile not exc 0.36 Sqm, in floors & vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,laid over and including 15 mm thick screed bed in CM(1:4) and including dismantling of floor hearth or wall tilling and rubbish off the premises, completed all as specified and directed
M&L for 10 mm thick coloured vitrified tiles (square/ rectangular) polished area of each tile not exc.0.36 Sqm as in vertical surfaces, skirting /dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including rendering 10 mm thick in CM (1:4) as backing coat to receive tiles including dismantling of old wall tiling of any description and rubbish off the premises, complete all as specified and directed. Note :- An amount of Rs 3349.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
devan enterprises
UNIVERSAL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .