| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹2.1 L (6.16%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹35.8 L+₹2.3 L (6.88%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹37.6 L+₹4.1 L (12.2%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹40.1 L+₹6.6 L (19.8%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Oct 2023, 6:00 pmClosed
MAJOR M K YADAV
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIRS / MAINTENANCE TO BOUNDRY WALL, HARDSTANDING AND PATH, FENCING AND CERTAIN OTHER MISC WORK AND EXTERNAL PERIODICAL SERVICES TO CERTAIN MD ACCN AND OTM ACCN IN NCES AND OTHER DOMESTIC AREA AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUND
2023_MES_618438_1
C/8903/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹80,000
Yes
7 Nov 2023
12 Sept 2023
10 Oct 2023
12 Sept 2023
9 Oct 2023
26 Sept 2023
Amount
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.complete all as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Dismantling posts or struts(wood ,steel or RCC) of any section including taking out embedded portion and making good disturbed ground with and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwiese provided for including gates all as sepcfied and directed
Dismantling of barbed wire of any description and in any positionwith and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed.
Dismantling of chainlink fencing of any description and in any position with and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed.
Dismantling of chainlink fencing of any description and in any position with and including clear vegatation on fencing and in floor area to facilatate demolition and moving old usable material for refixing in premisies of techenical/domastic area within 2.5 Km of any size and section complete all as specified and directed.
Dismantling of old and existing round bars as in stiffner to hold the chain link fencing of any description and in any position from fencing and moving old usable material complete all as specified and directed .
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil or any type of soil ,complete all as specified and directed.
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
Materials and Labour for plain cement concrete (1:3:6) Type C-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
M & L cement concrete type C2 1:3:6 (40 mm graded stone Aggregate) as in embedding of precast post as directed including necessary from work complete all as specified and directed.
M&L for RCC (nominal mix) M-20 (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams, bases for columns, etc. basement slabs, under reamed piles and mass concrete footings etc. complete all as specified & as directed
M&L for RCC (nominal mix) M-20 (using 20mm graded stone aggregate) in columns, pillars, piers, posts and struts column etc. complete all as specified & as directed
Materials and Labour for reinforced cement concrete M-20 nominal mix (using 20mm graded stone aggregate) in beams, cantilever, bressumers, lintels over 1.5M Span,complete all as specified and directed.
Materials and Labour for for 100 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate as in floor/paving/hardstanding/plinth protection, complete all as specified and directed.
M & L for chequered cement concrete tiles chemically treated , cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating, as directed including necessary from work complete all as specified and directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough concrete surface, flat complete all as specified and directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished faces of concrete square or rectangular complete all as specified & as directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), complete all as specified and directed.
All as per item No- above here in before but except bricks(brick obtained from demolition above here in before ) with and including removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish as directed.
M & L for brick work with fly ash brick class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed .
All as per above item 29.00 but fixing only with angle iron post including necessary welding and fixing arrangement complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & as directed
All as per item No- 31.00 above but 6 mm to 8mm dia complete all as specified & as directed
S & F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, quality confirming to GDE Fe410-W (Gde-E-250) complete all as specified and directed.
S&F mild steel works in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling ,bolting or riveting etc and similar works conforming to Fe-290 (Gde-E-165) as per IS 15911: 2010 complete all as specified and as directed.
All as per above item no. 34.00 here in before but fixing only complete all as specified and as directed.
Supply only mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed at other fitted with washer and nut 5 to 10mm dia and 50mm long complete all as specified and directed.
Supply and fixing galvanized steel chain link fence fabric of any mesh size made out of not less than 3.15 mm nominal dia of mesh wire conforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). Make Tata or equivalent make as approved by GE
M&L for Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc all as specified & as directed. (Note : Each line wire to be measured separately)
Materials and Labour for rendering 10 mm thick, cement plaster, in cement mortar (1:4) on surface on fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface on fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 5mm thick cement plaster in cm 1:3 on ceiling including finished even and smooth without using extra cement complete all as specified and as directed.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth using extra cement in walls/spetic tank/manholes/soakage pits etc, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Supply only Liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed (Make : CICO No- 1/SIKA/ACCO PROOF).
M & L for precast cement concrete louvers and jallies, 35 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings & including 6 mm dia reinforcement as per trade pattern or TD drawing but excluding frame and fixed in position using cement mortar (1:4) complete all as specified and as directed.
Preparation of newly plastered surfaces on wall and applying three coats of white wash complete all as specified and as directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls with applying two coat of 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including 2mm thick external wall care putty premium quality including a coat of primer to new plastered or unplastered surfaces on walls including preparation of surfaces, and including taking down cement plaster as specfied in SSR complete all as specified & directed.
Material and Labour for applying two coat of 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and 1mm thick average external wall care putty premium quality including a coat of primer to new plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.Note (Work shall be exectuted through authorised applicator of manufacturer,s and shall be get approved by GE before commencement of work)
Material and Labour for applying two coat of 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and 1mm thick average external wall care putty premium quality including a coat of primer to old plastered or unplastered surfaces on walls including complete removal of existing treatment and preparation of surfaces, complete all as specified and directed.Note (Work shall be exectuted through authorised applicator of manufacturer,s and shall be get approved by GE before commencement of work)
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
Material and Labour for complete removal of existing treatment and applying two coats of cement-based paint, white or tinted over and including priming with alkali resistant priming paint to old plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.
M&L for preparation of old painted surfaces of Steel surface of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel painting complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in surface channels and drains complete all as specified & as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
All as per item ser No 54.00 herein before above but add or deduct for each 25mm girth or part there of over or under 30 cm all as specified & as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on the wall all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coat of white washing on the wall all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on the ceiling all as specified and directed
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specifed and as directed.
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint on steel surfaces of any description not other wise described over 10 cm width or grith etc complete all as specifed and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat cement base paint on old surfaces complete all as specified.
M & L for applying Two 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall ,chajja, facia & ceiling surface) including preparation of surfaces,at any height and all necessary scaffolding and safety measures complete all as specified and directed
M&L for writing letters or figures Block, Roman, Italic or Indian) n.exc. 30 cm high with thick paint, so that they stand out boldly and solidly without showing signs of brush marks (if necessary, they shall be repainted until the desired result is obtained) complete all as specified and as directed.
M&L for writing stops, commas, short lines, dashes, hyphens, brackets etc with with thick paint, so that they stand out boldly and solidly without showing signs of brush marks (if necessary, they shall be repainted until the desired result is obtained) complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC with bends inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding, any type, any location/height (i.e roof, parapet walls near pipe etc) and applying acid after removing roots for preventing regrowth and making good the disturbed portion using PCC 1:2:4 Type B-0 and plaster in CM 1:3 (size of disturbed portion 150 x 150 x 150mm) complete all as specified and as directed by Engineer-in-Charge
SNEHANGI TRADERS
Ray Enterprise
Sai & Siva Enterprises
SUMAN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .