Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Technical AT PLOT NO 1662 FAKIRPUR PANDASAHI CUTTACK SADAR ODISHA 754021 | CUTTACK | ODISHA | 754021 | Admitted-Technical Q |
| 2 | Admitted-Technical AT BRAHMANABASTA KAKHADI CUTTACK 75437 | 75437 | Admitted-Technical Q |
| 3 | Admitted-Technical | Admitted-Technical Q |
| 4 | Admitted-Technical AT CUTTACK ODISHA | Admitted-Technical Q |
| 5 | Admitted-Technical AFIPO GUGARI GALI NANDAPARA THARVAPARA DIST SAMBALPUR | Admitted-Technical Q |
Tender Value
Refer Docs
EMD Value
₹11,300
Closing Date
15 Apr 2026, 5:00 pmClosed
SE CUTTACK R AND B DIViISION II
SE CUTTACK R AND B DIViISION II OMP SQUARE CUTTACK
Improvement to Leprosy Home and Hospital, Cuttack such as Supply and Installation of AIO Led Solar Street Lights at OT, Ward, Office, Male Ward and Female ward
2026_EICCL_127872_1
SE CTC (RnB)-II -22 of 2025-26
Open Tender
Civil Works - Buildings
Percentage
30 days
SADAR
AS PER DTCN
3 documents required · 3 mandatory
₹6,000
₹11,300
Yes
10 Aug 2026
6 Apr 2026
16 Apr 2026
6 Apr 2026
15 Apr 2026
6 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of Elegant look 60 W / 66 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens and having lumen efficacy not less than equal to160 lm/w) as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light ) Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT or equivalent).
NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. The battery and panel figures are indicative only. Final procurement shall be done after approval of panel and battery backup calculation from Superintending Engineer, Electrical Circle (R&B) Odisha, Bhubaneswar and Chief Engineer (buildings) Odisha, Bhubaneswar. | 12 | Each | - | - |
| 2 | Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos.
Jtype En 8 grade foundation bolts to withstand 180 KM / HR or more wind speed considering
the weight & dimension of 1 no 60 W AIO Solar light to be fitted in the pole ( One light on Pole Top ).The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1no 60 W AIO Solar light to be fitted in the
pole top to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The figures of base and top diameter are indicative. It shall be finalized only after approval of the said test reports by the competant authority from civil wing (SE, Cuttack (R&B) Division No.II CCE Cuttack (R&B) Circle, Cuttack)before execution of the work.
(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh/Equivalent) | - | Each | - | - |
| 3 | Construction of RCC foundation by using M25 gradeRCC and Fe415 grade reinforcementin
the foundation and fixing 4 nos. EN8 grade foundation bolts in that foundation for
installation of pole with solar lighton that foundation.The work shall be executed as per the
instruction of EIC . | - | Each | - | - |
| 4 | Installation of 6 mtr pole on the adaptor plate after fixing the AIO Solar Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC. | - | Each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.39 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
DTCN.pdf
Tender Documents • 1.46 MB
BOQ_587141.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .