GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/ROUTINE MAINTENANCE OF DG SETS, AMF PANELS AND OTHER MISC E/M INSTALLATION AT AF STN FARIDABAD IN AOR OF GE (AF) FARIDABAD
2024_MES_640792_1
GE (FBD)/AF-86/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹94,000
Yes
27 Mar 2024
5 Feb 2024
11 Mar 2024
5 Feb 2024
9 Mar 2024
24 Feb 2024
5 Feb 2024 - 9 Feb 2024
Amount
M&L for General Servicing of DG sets upto 160 KVA , at run of 500 hours or 5 months which ever comes first (twice in Contract period based on condition ) comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing at site of make of DG Set - CG/Cummins/Mahindra etc. as reqd complete all as specified and directed by Engineer-in-Charge. Note - Servicing through OEM authorised rep or service engineer from the manufacturer only and Cost of unserviceable items will be measured and paid seperately under relevant following items incl rates for service charges:- (a) S&F lubrication of oil filter (b) S&F by pass filter (c) Cleaning of hydraulic governer (d) S&F Checking and toping up of coolant (e) S&F fuel filter (f) S&F air cleaner element (g) S&F in Air filter (h) Cleaning of radiator complete set (j) Engine oil as per manufacturer specification and any other checking as per manufacturer instruction
All as per item No1 above but capacity of DG set 100 KVA
All as per item No1 above but capacity of DG set 82.5 KVA
All as per item No1 above but capacity of DG set 62.5 KVA
All as per item No1 above but capacity of DG set 25 to 40 KVA
Supply only the following items of DG Set of various capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 06 above but Battery terminal, lug, bolts type suitable for heavy duty battery 12/24 V.
All as per item No 06 above but Battery leads copper conductor multi wired 35 Sqmm.
All as per item No 06 above but Hinges for DG set door of any size, any type as required on site.
All as per item No 06 above but Servo cool plus Radiator coolent
All as per item No 06 above but Low viscosity synthetic Engine oil 15W40
M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check and pressure testing including transporting to repair workshop and bringing back for upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 12 above but capacity from 82.5 KVA upto 200 KVA
Supply, replacment and testing of radiator assembly of DG Set 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply, replacment and testing of radiator assembly of DG Set 82.5 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of low lube oil pressure sensor upto 160 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 17 above but capacity from 82.5 KVA upto 200 KVA
M&L for Removal & replacement of fly wheel gear ring suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 19 above but capacity from 82.5 KVA upto 200 KVA
M&L for Removal & replacement of thermostat suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 21 above but capacity from 82.5 KVA upto 200 KVA
Supply and fixing in repair of AVR for DG set having capacity 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 23 above but capacity from 82.5 KVA upto 200 KVA
Supply and fixing in all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 25 above but capacity from 82.5 KVA upto 200 KVA
S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 100 KVA complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as specified and directed by Engineer-in-Charge.
All as per item No 28 above but capacity Battary Charger 24V DC, 10 Amp complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water for top up in Batteries complete all as specified and directed by Engineer-in-Charge.
Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon Each packing complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in DC 12V Stop Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in DC 24V Self Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 100 AH suitable for DG set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 180 AH suitable for DG set complete all as specified and directed by Engineer-in-Charge.
M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed by Engineer-in-Charge.
All as per item No 36 above but capacity 24 Volts complete all as specified and directed by Engineer-in-Charge.
S & F Copper Battery leds suitable for Bty 12V complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 39 above but capacity from 82.5 KVA upto 200 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and make all electric connection and testing for smooth operation complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair IOPS Module digital display controller unit suitable for exisitng DG Set complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with breaking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 3 pole 415 volts in repairs,fixed type 63 Amps to100 Amps with breaking capacity 16 KA.after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB 3 pole 415 volts fixed type 200 Amps with breaking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB 3 pole 415 volts fixed type 250 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engineer-in-Charge.
S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F for fuel pipe from fuel tank to fuel filter for DG Set 82.5 KVA to 200 KVA complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing of charging alternator 12 V/24V complete all as specified and directed by Engineer-in-Charge.
Supply and fixing mounting rubber bushing set of 6 for existing generator complete all as specified and directed by Engineer-in-Charge.
S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
S&F Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed by Engineer-in-Charge.
S&F Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed by Engineer-in-Charge.
M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and directed by Engineer-in-Charge. Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.
M&L spray gun painting of generator upto 62.5 KVA in existing colour with smooth finish with minimum two coats of paint complete all as specified and directed by Engineer-in-Charge.
M&L spray gun painting of generator 82.5 KVA upto 160 KVA in existing colour with smooth finsh with minimum two coats of paint complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 175 C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Material and Labour for fixing white boards 5' x 4' as per site details of Line digram / Machine History /Distribution boards complete all as specified and directed by Engineer-in-Charge.
M&L for repair maintenance of Steel rolling shutters greasing and synthetic enemal paint blue / black colour, including ball bearing, anchoring rod, hasp and staple push pull or manual type as per site requirement complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per item No 67 above but size 185 Sqmm 3.5 core
All as per item No 67 above but Size 95 sqmm 3.5 core
All as per item No 67 above but Size 70 sqmm 3.5 core
All as per item No 67 above but Size 50 sqmm 3.5 core
All as per item No 67 above but Size 35 sqmm 3.5 core
All as per item No 67 above but Size 25 sqmm 4 core
All as per item No 67 above but Size 16 sqmm 4 core
All as per item No 67 above but Size 10 sqmm 4 core
Supply and Fix cable jointing kit,heat shrink type for 1100 volts grade,XLPE insulated armoured heavy duty electric cable with aluminium conductor,cross sectional area 6-16 Sqmm 4 core complete with jointing material and accessories including testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 76 above but Size 25-35 sqmm 4 core.
All as per item No 76 abvoe but Size 50-95 sqmm 3.5 core.
All as per item No 76 above but Size 120 - 185 qmm 3.5 core.
S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed by Engineer-in-Charge.
S&F MNX 18, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
S&F MNX 70, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
S&F Panel LED indication lamps (R/Y/B) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Rotary switch of existing make L&T complete all as specified and directed by Engineer-in-Charge.
S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of capacitor 3 phase, 5 KVAR complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of capacitor 3 phase, 10 KVAR complete all as specified and directed by Engineer-in-Charge.
S& F in capacitor 3 phase, 25 KVAR complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of capacitor 3 phase, 2 KVAR complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of capacitor 3 phase, 3 KVAR complete all as specified and directed by Engineer-in-Charge.
Supply and install reactive power manager in existing APFC panel complete all as specified and directed by Engineer-in-Charge.
M&L for servicing/testing of APFC(Automatic Power Factor Control) panel including checking of all internal connetions and replacement of spares if required complete all as specified and directed by Engineer-in-Charge. Note - Spares to be measured and paid separately
M & L for High quality powder coating on electric panels (Cubicle) installed at different places of size not less than 1050x1050x450 mm with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off,applying one coat of metal primer by disconnecting,removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed by Engineer-in-Charge.
Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine with HDPE Pipe, PN 10,100 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
All as per item No 96 above but 50 mm dia
All as per item No 96 above but 40 mm dia
Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge.
Material and Labour for servicing of split type AC's of capacity 1.5/2 TR comprising of the following works installed at different locations including testing complete all as specified and directed by Engineer-in-Charge. (a) Inspecting and checking the Indoor/outdoor units for noise free operation. (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun. (d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage by pressure testing and repair it. (f) Checking for serviceability of remote control unit and replace with new battery.
Supply and fixing in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of start run capacitor 45/60 MFD for split type A/C's of capacity 1.5/2 TR complete all as specified and directed by Engineer-in-Charge.
Taking out and replacement of condenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and directed by Engineer-in-Charge.
Taking out and replacement of condenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of PCB card with display unit suitable of 1.5/2 ton split AC indoor unit as required on site complete all as specified and directed by Engr-in-Charge
S & F in replacement of PCB card suitable of 1.5/2 ton inverter split AC outdoor unit as required on site including sensor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of out door fan blade in existing model complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of indoor blower set complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and Supply and Fix new copper condesor coil as per existing model including testing complete all as specified and directed by Engineer-in-Charge.
Supply and replace cooling coil assembly complete suitable for 1.5 / 2 ton indoor unit Split type AC incl testing for satisfactory working condition all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and fix new one as per existing model including testing complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and fix new one as per existing model including testing complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type of gas charging complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of the new blower motor DC for split type A/C unit as per existing model complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement of split AC 1.5 ton indoor unit complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of the new blower motor AC for split type A/C unit as per existing model complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of cable 3 core copper PVC insulated of size 4 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and directed by Engineer-in-Charge.
M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 120 above but 5/8” outer dia.
S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement of Split AC 1.5 ton outdoor unit complete all as specified and directed by Engineer-in-Charge.
Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of wall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of wood pads(set of three) as per sample of steel body desert cooler complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement new desert cooler pump.including testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement new exhaust fan kit with leg assembly 450mm sweep of steel body complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement new exhaust fan motor with leg assembly 450mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement new exhaust fan blade 450mm sweep of steel body complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of front grill of desert cooler as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC flexible distributor heavy duty as per sample complete all as specified and directed by Engineer-in-Charge.
All as per item No 135 above but nozzle complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed by Engineer-in-Charge.
Material and Labour for servicing of window type AC's of capacity 1.5 TR comprising of the following works at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge. (a) Inspecting, taking down, brushing cleaning with water pressure gun including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system by pressure test and repair it. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f) Inspection of all electrical parts. (g) Testing the machine for satisfactory operation.
Supply & fixing in replacement of running capacitor for 36/60 mfd for AC window type 1.5 TR as required at site complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of new blower motor 1 HP as required at site single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes including testing & commissioning complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repair to leakage area of window type AC unit of 1.5 Ton capacity including pressure testing, dehydration and any type of gas charging complete all as specified and directed by Engineer-in-Charge.
S&F 'R' type compressor for Window type AC,1.5 TR as per existing make including taking out old unserviceable one,flushing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge.
S&F cooling coil of window type AC 1.5 TR including taking out old unserviceable one,soldering/welding dehydration and testing complete all as specified and directed by Engineer-in-Charge.
Disconnecting & taking down of window type AC of any make for replacement of condenser coil of existing size including soldering/welding and refixing commissioning complete all as specified and directed by Engineer-in-Charge.
Repair & maintenance of Refrigerator any capacity comprising of the following works at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f) Inspection of all electrical parts. (g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigerator after repair.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
BLANK
M&L Unplasticised PVC pipes 25 mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge.
M&L Sub main wiring with two run of 4.0 sqmm single core, FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 volts drawn through in and including consealed PVC conduit of 25 mm dia with all accessories and 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor cable as earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note: Two run of 4 Sqmm PVC cable with one run of PVC conduit and one run of PVC earth wire shall be measured and paid as one length only.
Labour only for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete all as specified and directed by Engineer-in-Charge.
Labour only for fixing of Split AC 1.5/2 ton including masonary work complete unit complete all as specified and directed by Engineer-in-Charge.
Labour only for dismantling of window AC 1.5 ton from the existing place complete all as specified and directed by Engineer-in-Charge.
Labour only for fixing of window AC 1.5 ton complete all as specified and directed by Engineer-in-Charge.
Supply and fix metallic Ventilation fan (250 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Supply and fix metallic Ventilation fan (200 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including greasing,oiling,replacing wornout bearing ,bush and refixing the same at site incl testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 157 above but for Exhaust fan 300 mm sweep.
All as per item No 157 above but for Exhaust fan 450 mm sweep.
All as per item No 157 above but for wall/floor mounted fan 450 mm sweep.
M&L for Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original gauge of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 161 above but for Exhaust fan 300 mm sweep.
All as per item No 161 above but for Exhaust fan 450 mm sweep.
All as per item No 161above but for wall/floor mounted fan 450 mm sweep.
S&F in repairs Capacitor 2.5 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
BLANK
S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
NAVYUG VYAPARI
ETERNITY PROJECT
national engineering
M P TYAGI ENGINEERS AND CONTRACTORS
Surjit and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .