Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32.4 CrAdmitted-Finance | +4.77% | ₹32.4 Cr | L1 | Admitted-Finance |
Tender Value
₹31 Cr
EMD Value
₹62 L
Closing Date
30 Jun 2025, 6:00 pmClosed
Chief Engineer M and H Jaipur
Chief Engineer M and H Jaipur
Construction of New District Hospital at Khivsar distt. Nagaur (Including Internal Electrical work) (State Head 2025-26
2025_MEDIC_478325_1
NIT No.07/2025-26 CE Medical and Health Jaipur/
Open Tender
Civil Works
540 days
Nagaur
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
RTGS/NEFT/Any other money Transfer System
₹62 L
22 Jul 2025
11 Jun 2025
1 Jul 2025
11 Jun 2025
30 Jun 2025
11 Jun 2025
Amount
Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v -467v/ full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance free). Communication & management i.e.
30 KVA (3 phase input & 3 phase output)
For 30 minute backup, min. 24000 VAH
Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications.
EPABX system consists of 64 nos. extensions, 16 nos of junction & upto 128 nos. of expandable eport, with one operating console, 3 Amp max. current
Supply, installation, testing and commissioning of telephone instrument as approved by architect (Siemens/ Panasonic/ Tata/ BPL)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.62 MB
Tendernotice_2.pdf
PDF • 5.32 MB
Tendernotice_3.pdf
PDF • 0.07 MB
Tendernotice_4.pdf
PDF • 2.69 MB
Tendernotice_5.pdf
PDF • 0.31 MB
AnnexureB-ElectricalDLP.pdf
Tender Documents • 0.24 MB
BidDocument-DHKhivsar.pdf
Tender Documents • 5.42 MB
BOQ_854708.xls
BOQ • 1.06 MB
AnnexureC-ElectricalSpecialTandC.pdf
Tender Documents • 0.34 MB
Tenderdocument.pdf
Tender Documents • 0.24 MB
Tenderdocument_2.pdf
Tender Documents • 0.34 MB
BOQ.xls
BOQ • 1.08 MB
Tenderdocument_3.pdf
Tender Documents • 5.42 MB
Download all tender documents and submit your bid