Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹52.2 L+₹5.6 L (12.0%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹53.0 L+₹6.4 L (13.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | - | Rejected-Technical APPRO CAT NOT FOUND HENCE REJECTED |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
15 Jun 2020, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PROVISION OF SOLAR BASED COOKING ,SOCKET POINTS CONNECTIONS IN NS-9 , WATER COOLERS FOR SPDC-20 , ADDN / ALTN TO SUPPLY LINE NS-198 AND SPL REPAIRS TO REPLACEMENT OF BER SUMMER/COOLING APPLIANCES AT MO(MB) GHATKOPAR
2020_MES_338278_2
8829/B
Open Tender
Civil Works
Item Rate
184 days
GHATKOPAR
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat c(i),b(i)
9 documents required · 9 mandatory
₹500
GE (NW) BHANDUP
₹89,000
17 Oct 2020
26 May 2020
19 Jun 2020
26 May 2020
15 Jun 2020
3 Jun 2020
26 May 2020 - 30 May 2020
Amount
Supply, Installation and commissioning of Solar Panels suitable for minimum 500 LPD ,Heating Output should be not less than 125 LPD at 80 degC from each solar panel, accessories with structure, internal piping , valves , strainer and control panel for solar system. The system to comprise of solar collectors with structure , primary ciculation pump of 105 lph per panel .Each panel to be designed for 2.5 bar working pressure , the no of risers to be 9 and dia to be for header 18/22mm and Dia of absorber tubes to be 10/12 mm,the glass should be low iron tempered glass with transmittance minimum 91% of minimum 4 mm thickness.The wall thickness of absorber tubes should be 0.45 mm , the thickness of the header tube should be 0.70 mm . the sealing material should be EPDM and silicone . The absorber should be made our of Aluminium / Pre coated box with a minimum absorbtance 95% . The insulation should be minimum 50 mm Glass wool. The aperture area to be Minimum 1.92 m2. including civil works and operation and maintenance for 5 years along with warranty of the system complete all as specified and directed Make: Racold/ TATA BP Solar
M& L for brass NRV 20 mm dia for iron pipes fixed for size 20 mm complete all as specified and directed.
M&L for gunmetal gate valve with iron wheel head, screwed both ends for iron pipes fixed for size 20 mm complete all as specified and directed.
M&L for brass ball valve with iron wheel head, screwed both ends for iron pipes fixed for size 20 mm dia with air vent complete all as specified and directed.
M&L for Structure for Solar Panel angle iron, drilled holes duly painted with two coats of synthetic enamel paint over a coat of read oxide including fixing bolts etc of sutable size fixed on pole, wall etc complete all as specified and directed.
Supply of Horizontal multistage centrifugal pump with SS304 Body & Internals. Each pump shall have TEFC SINGLE phase electric motor, 2900 RPM. Pump shall be provided with mechanical seal. The pump shall be suitable for hot water system and auto/manual operation. (a) Supply , installation, commisioning & testing of Primary Horizontal Hot Water Circulation pump (1W + 1S), of following capacity flow : 1500 LPH and Head:25 Mtr including civil works and operation and maintenance for 5 years along with warranty of the system complete all as specified and directed.
Supply and fixing Butterfly Valve 25 mm dia complete all as specified and directed
Supply and fixing Y type Strainer for 25 mm dia complete all as specified and directed.
Supply of Hot Water Calorifier tank cap. 500 Ltrs . Insulation-50mm thick Polyurethane Insulation/ 100 mm Rockwool and outer PVC flexible jacket./ Aluminium operating pressure: 1 kg/cm2
M&L for GI tubing medium grade 25mm dia fixed on surface including all accessories like bend, union, elbow, Tee etc complete all as specified and directed.
M&L for gunmetal gate valve with iron wheel head, screwed both ends for iron pipes fixed for size 25 mm complete all as specified and directed.
M&L for GI hot water pipe medium grade duly insulated with glass wool and aluminium clading 25mm size fixed on wall, floor, ceiling etc complete all as specified and directed.
Supplying, laying & fixing of 3C x 2.5 sq mm PVC insulated FRLS industrial flexible cable of 1.1 KV grade on surface / recess/in existing PVC/GI pipe complete with connections etc as reqd. complete all as specified and directed.
M & L for FTC ( Fix temperature based ) Control panle Box made up from CRC or Engineering Plastic base with Electronic controller, relays, contactors with all relevant wiring and everything required for smooth working of the system including civil works and operation and maintenance for 5 years along with warranty of the system complete all as specified and directed
Supply, Installation, testing and commissioning of 300 Wp ( minimum rated) poly Crystalline silicon photovoltaic (PV) modules high power solar cells on existing metal frame. solar cells used in solar photo voltaic module shall be as per IEC 61215/IS: 14286 & IEC 61853 amended upto Latest standard .Each PV module used shall have a RF identification tag. Efficiency of SPV modules shall be greater than 16 %. It shall perform satisfactorily in relative humility upto 100% with temperature variation between (-) 10 Degree C to (+)65 Degree C. etc. i/c inter connection DC wires with MC4 connectors with IP 67 protection including civil works and operation and maintenance for 5 years along with warranty of the system complete as required as per specification Make :TATA Power/ ORB/ JAIN Solar
Supplying , laying , connection and Testing following sizes of PVC insulated copper multi strand conductor DC cable with connector with IP 67, suitable for 1800 DC voltage , Heat Resistant upto 120⁰C ,UV Resistant, fixing with pvc button belt / tie with existing structure / cable tray or in the existing surface / recessed steel / pvc conduit as required a) 1 core x 4 sq mm (Cable for String of dc power)
Supply, installation, testing & commissioning of following 7.5 KVA off Grid inverter to convert DC power produced by solar module to charge the battery bank and then convert to AC power. The inverter should be hybride type and equipped with MPPT(Maximum Power Point DC Array Input Operating Voltage : 120 V Type of Solar Charge Controller : MPPT based Output Wave Form : Pure Sine Wave Total Harmonic Distortion : < 3% with resistive load Output Voltage : 230 +/- 3% Output Frequency : 50 Hz +/- 0.5 Hz Inverter efficiency : > 85% Operating temperature : 0 - 50 Degree C Relative Humidity : 95% non-condensing Protection of enclose : IP 55 ( Indoor Type) Make: TATA/ Power One
supply and fixing Battery type maintance free Lead acid battery Capacity 12V 150 Ah Make / TATA/Exide/ Equivalent in other makes complete all as specified and directed. Make: TATA/ Exide
Providing and fixing 25 mm X 4 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and fixing of following size medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in the case of recessed conduit as reqd of size 25 mm complete all as specified and directed.
Supply, Installation, testing and commissioning of 4 in 4 out, Aarre Junction box with minimum IP 65 protection which i/c DC configuration of (Fuse, DC switch, & suitable to operation of 5 KW off grid inverter complete with connections etc as required.
Supply and fixing GI Module Mounting structure for solar panels complete all as specified and directed.
Material and labour for Hot Plate for Canteen 1500 Watt complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed by the Engineer-in- Charge.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm laid in trenches complete all as specified and directed.
Supply and laying GI pipe 80 mm, light grade for the protection of the cable passing through road crossing, etc.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 120 Sqmm, 3.5 core complete all as specified.
Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of stainless steel 3 mm thick (SS316) sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 400 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer Loc: Near Safalya
Incoming: MCCB 4 pole 250Amp with breaking capacity 36 KA adjustable type with exended terminals -01 Nos Outgoing [a] MCCB 4 pole 125 Amps with breaking capacity 25KA adjustable type with extended terminals- 01No's [b] MCCB 4 pole 100 Amps with breaking capacity 25 KA adjustable type with extended terminals- 01 No's [c] MCCB 4 pole 40 Amps with breaking capacity 16 KA adjustable type with extended terminals- 02 No's Make : Legrand/Schneider/siemens (d ) LED indicating lamp RYB -01 Nos (e) Multifunctional Meter (Voltage, Amphere and frequency) including CT -01 Nos
Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out ofstainless steel 3 mm thick (SS316) sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 1000 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer Loc: Main power house
Outgoing [a] MCCB 4 pole 400 Amps with breaking capacity 35KA adjustable type with extended terminals- 04No's [b] MCCB 4 pole 100 Amps with breaking capacity 25 KA adjustable type with extended terminals- 06 No's [c] MCCB 4 pole 63 Amps with breaking capacity 16 KA adjustable type with extended terminals- 02 No's [d] Bus coupler ACB 800 Amps 50 KA 3 pole mannual draw out type- 02 No's Make : Legrand/Schneider/siemens (e ) LED indicating lamp RYB -03 Nos (f) Multifunctional Meter (Voltage, Amphere and frequency) including CT -03 Nos (g) Current transformers 800/5 Amps CL-1.0 tape wound -09 Nos (h) Programmable logic controller for interlocking of 3 incoming and 3 Bus bar couplers-01 set
Supply installation testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm).There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter.FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top.The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA.The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIS accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.
Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor .
M&L for point wiring for 5 pin 5 Amps socket outlet on the independent board with ohter socket points with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC casing capping having thickness not less than 2 mm with all fittings including modular steel sunk box having thickness not less than 2 mm including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed casing caping/naked wires on floor to workstation and making good disturbed surface/floor area and white wash/colour wash to matching with the existing floor/surface colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza)
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed for concealed casing caping/naked wires on floor to workstation and making good disturbed surface/floor area and white wash/colour wash to matching existing colour of floor/surface and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
M&L for submain wiring in and including PVC conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for switch modular one way 6/5 amps 1 module complete all as specified.of make: legrand/ Havells/ Elvira (Indo Asian)
M&L for switch modular one way 15/20 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 16 to 40 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 12 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 12 module complete all as specified and directed.
M & L for earthing complete with Copper earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using Copper lead 4 mm dia by means of bolts, nuts, check nuts and washers of Stainless Steel upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No3 of MES Schedule Part – I of 2009.
Dismantling of existing u/s water cooler of 80 Litr Capacity and transport to AGE E/M store yard.
Storage water Cooler of 80 Ltrs capacity with in built UV system and 60 ltrs / hrs cooling capacity including 3 stage filtration of sedimentation filteration carbon fileteration and UV system with stainless steel body,AC single phase,240 volts complete with connecting water supply dfrain connections and testing etc
Dismantling of existing u/s window type air conditioners of 1.5 Ton Capacity and transport to AGE E/M store yard.
Supply and installation of Split type air conditioners inverter type 1.5 Ton capacity 5 star rated including indoor and outdoor units with necessary copper tubing and AC current supply,single phase,240 volts and connect and testing as per direction.Make.Blue Star/Daikin
cooltech engineering services
GRAND SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .