Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹29.7 L+₹1.1 L (3.81%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹31.4 L+₹2.8 L (9.82%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹35.6 L+₹7.1 L (24.7%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
27 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIRS/MAINTENANCE OF VARIOUS CENTRAL/PACKAGE TYPE AC PLANTS AND ITS RELATED WORKS SUCH AS REPLACEMENT OF FILTERS V BELTS PULLYS CONTROLS AT 512 ABWS CAFVD UNDER AGE E/M II (C) IN GE (C) KIRKEE
2021_MES_470181_2
CWE/KKE/T-16 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹80,000
Yes
18 Nov 2021
14 Sept 2021
29 Sept 2021
14 Sept 2021
27 Sept 2021
14 Sept 2021
60 days
Amount
S & F in repairs First Aid Box at E/M installations to keep the first aid items i.e. Tube of bernol, Bandage, one small snizer, banded etc, the box made out of GI sheet of 18 gauge of size 30 cm X 25 cm x 20 cm with openable window & writing letters "FIRST AID" with thick red paint and fixed on wall at height not less than 2 mtr complete all as directed and specified by Engineer- In- Charge.
Supply and fixing in repair CI Pot Strainer/ Y Stainer with matching flanges, gasket, hardware all as specified and directed of following sizes as per site requirment.
(d) 80 mm bore
(c) 100 mm bore
S & F Rotational moulded polyethylene water storage tanks 1000 lts capacity, double layered 'ISI' marked (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description and in any position complete all as directed.
S & F in repair installation informatory boards at E/M installation to display the technical details i.e.(Type of AC plant, capacity, Design condition, Date of installtion, Installed by, Compressor type, Compressor motor, Condensor motor, AHU motor, cooling tower motor, AHU motor and if chilled water type chiller motor) of AC plant made out of 3mm thick aluminium composite panel (ACP) fully covered with white/green/blue (as required) Retro Reflective sheeting of Nikkalite Brand Ultralie (UL) grade with using pressure sensitive adhesive and Retro Reflective cut out border and messages in the sensitive adhesive, size of the board 150 cm x 120 cm fixed on wall above 1.2 mtr above ground level with & including proper fixing arragement complete all as specified and directed. Note : Technical details as per direction of Engr-in-charge.
Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid , flushing/cleaning with brush and water, re-fixing the side cover with new gasket nut / bolts and detect leakage all as specified and directed by Engineer -in-Charge. Note : Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
Material and Labour for Servicing/Cleaning of FRP cooling tower of following capacity by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge.Note : Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
a) 16 TR to 45 TR
b) 50 TR to 100 TR
c) 110 TR to 200 TR
Disconnecting/Isolating the compressor from the system by putting plates to the suction and discharge valve opening of the compressor. Dismatling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as directed by engineer in charge. Note : Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items.
Supply and fixing in replacement of following spares for compressor make :- Kirloskar/Accel / Sabro 8-65/6-65/4-65 model. All as specified & directed .
a) Piston
b) Piston ring
c) Pisotn pin
d) Shaft seal assembly
e) Discharge valve reeds
f) Loading Unloading Frame
g) Main bearing Bush
h) CR bearing
j) Gasket set for 6-65
k) Gasket set for 8-65
l) Gasket set for 4-65
m) Aluminium washer set
n) Oil pump assembly
o) Oil ring
p) O Ring set
q) Solenoid valve for loading & unloading
r) Split pin
s) Sunction valve reed
t) Thrust collor
u) Oil filter
v) Cylinder liner
w) Oil drain valve
x) Bushing for connecting rod
y) Crank shaft complete for SMC 6-65
z) Crank Shaft for SMC 8-65
z) Crank Shaft for SMC 4-65
Supply and fixing in replacement of following spares for compressor of AC-470 (Make : Kirloskar) all as directed by Engr-in-charge.
a) Connecting rod assembly
b) Piston
c) Piston ring
d) Gudgeon Pin
e) Shaft seal assembly
f) Paper filter
g) Sunction valve reed
h) Discharge valve reed
j) Gasket set
k) O ring set
l) Solenoid valve
m) Main Bearing
n) Cylinder liner
o) Oil drain valve
p) Oil pump assembly
q) Crank Shaft for AC - 470
Supply and filling nitrogen gas for leak testing of central & package A/C plants all as directed by Engr-in-charge.
Supply and filling of R-22 Gas in central & package A/C plants all as directed by Engr-in-charge
Supply and fillling compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter all as directed by Engr-in-charge.
Supply and fixing in replacement of defective brassomatic pressure releas valve of suitable size for 300 PSI refrigerent gas pressure complete all specified and as directed
Dismantling, Removing the unserviciable spares from A/C plant of any make & supply & fix new spares for A/C plant of following specifications all as directed by Engr-in-charge.
a) HP/LP cutout MP 15R
b) Oil Pressure Switch MP 55
c) Teflone TAL- O Ring 50 & Tal 40
d) Brass angle valve 1/4" for freon gas
e) 1 1/8" Brass valve Teflone sheet
f) Adaptor for valve 3/8" x 1/4"
Supply & fixing in replacement of over load relays type MN relay range 14-23 A complete all as specified . Make : L & T or equvilant to BCH/SIMENS as approved by GE
Supply & fixing in replacement of over load relays type MN relay range 24-40 A complete all as specified . Make : L & T or equvilant to BCH/SIMENS as approved by GE
Supply & fixing of MCCB 63 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all specified and as directed Make :- L & T or equvilant to ABB/Legrand as approved by GE
Supply & fixing of MCCB 100 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all specified and as directed Make :- L & T or equvilant to ABB/Legrand as approved by GE
Supply & fixing of MCCB 125 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all specified and as directed Make :- L & T or equvilant to ABB/Legrand as approved by GE
Supply & fixing of MCCB 200 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all specified and as directed Make :- L & T or equvilant to ABB/Legrand as approved by GE
Supply & fixing of MCCB 200 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all specified and as directed Make :- L & T or equvilant to ABB/Legrand as approved by GE
Supply & fixing of MCCB 250 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete. Make :- L & T or equvilant to ABB/Legrand as approved by GE. Note : For item No 18.00 to 23.00 - (i) All cable connections should be done with supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old u/s switch gear is deemed to be included in the quoted rates.
Supply & fixing in replacement of following spares for central AC plant ;-
a) Indicating lamps RYB - 01 Set
b) 'V ' belt of size / No A 28 make - Fenner
c) 'V ' belt of size / No B 85 make - Fenner
d ) 'V ' belt of size / No B 108 make - Fenner
e) 'V ' belt of size / No C 156 make - Fenner
f ) Power Contactors ML1.5 Make - L & T or equvalant to Simens/BCH as approved by GE
g ) Power Contactors ML2 Make - L & T or equvalant to Simens/BCH as approved by GE
h) Power Contactors ML3 Make - L & T or equvalant to Simens/BCH as approved by GE
i ) Power Contactors MNX 18 Make - L & T or equvalant to Simens/BCH as approved by GE
j) Power Contactors MNX 22 Make - L & T or equvalant to Simens/BCH as approved by GE
k) Power Contactors MNX 40 Make - L & T or equvalant to Simens/BCH as approved by GE
l) Power Contactors MNX 50 Make - L & T or equvalant to Simens/BCH
m) Power Contactors MNX 70 Make - L & T or equvalant to Simens/BCH as approved by GE
Labour only for detection of leakage and repairing of central type AC Plant of capacity 24 TR to 60 TR capacity by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results. Note :- Nitrogen gas and refrigerant will be measured and paid separately.
Dismantling of Air Handling Unit of any capacity with complete accessories such as cooling coil ,air filters,blower motor, blower / drum ,blower shaft,side panels , and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cutter complete all as specified and directed .
Re-assembling/Refixing the complete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by using CTC solution including remetling ,fine grinding blower shaft and hardening balancing , realignment to AHU shaft, replacing unserviceable blower fins ,replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrozen gas and testing and commissioning all as specified and directed by Engr-in- Charge
Supply and fixing Cast iron Sluice valves class PN 1.6 of size 100mm dia (4") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Supply and fixing Cast iron Sluice valves class PN 1.6 of size 80mm dia (3") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Taking out unserviceable liquid line valve/discharge line valve from refrigerant line of different size/type for necessary replacement all as directed including cutting / welding of existing pipe line complete.
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 40 mm dia pipe line including brazing/welding,fixing all as diected and specified
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 25 mm dia pipe line including brazing/welding,fixing all as diected and specified
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 20 mm dia pipe line including brazing/welding,fixing all as diected and specified
Supply and fix thermostate expansion valve of suitable size for 22TR/30TR capacity air conditioning plants including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 15TR capacity air conditioning plants including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 7.5TR capacity air conditioning plant including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 5TR capacity air conditioning plants. including taking down the unserviceble valve.
Supply & fixing water pressure gauge 0-7 Kg/Sqm including taking down the unserviceble gauge.
Supply& fixing refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gauge.
Supply and fix in replacement of pressure release valve of condensor 3/8" BSP threaded suitable for 300 PSI
Supply and Fix in replacement of DB/WB thermometer wall mounted with the facility of RH readings.
Taking down carefully and overhauling of Monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable wornout bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump:-
(a) 7.5 HP to 10 HP
(b) 12.5 HP to 20 HP
Material and Labour in replacement of 50mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 40mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 25mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 20mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Supply and fix Gate Valves (Brass Insert) of 50 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
Supply and fix Gate Valves (Brass Insert) of 40 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
Supply and fix Gate Valves (Brass Insert) of 25 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
Supply and fix Gate Valves (Brass Insert) of 20 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
Supply & fix float valve/ball type assemblt complete of size 20 mm size dia.
M&L for Painting of CI/GI/MS pipes of Air / Water distribution of size 100 / 80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code directed by Engr-in-Charge.
M&L painting to cooling tower inside and outside with one coat of primer and one coats of epoxy paint of approved colour including scapping out the old paint complete all as specified and and directed by Engr-In-charge.
M&L for painting of storage tank with one coat of primer and one coats of synthetic enamel paint approved colour including scapping out the old paint complete all as specified and directed by Engr-In-charge.
M&L for preparation of surfaces for painting of compressor unit of capacity up to 45 TR with motor, one coat of synthetic enamel paint including painting to suction line, discharge line, liquid line , guard base foundation etc. all as specified and as directed.
Material and Labour for Mild Steel brackets, frames ,supports, channels and stands of type as required at site made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 500 x 50mm.
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 400 x 50mm.
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 610 x 610 x150mm.
Material and Labour for for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Material and Labour for for Copper piping 1 1/8" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds or frame etc.
Material and Labour for for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 70 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells as approved by GE
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells as approved by GE
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 25 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells as approved by GE
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells as approved by GE
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 6 Sqmm 3 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells as approved by GE
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5 HP to 12.5 HP all as specified and directedas approved by GE
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 15 HP to 30 HP all as specified and directed as approved by GE
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 30 HP to 40 HP all as specified and directed as approved by GE
Disconnection and taking out old defective Hermetically reciprocating sealed compressor unit as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage,vaccumising etc of capacity 3 TR for pakage AC plants of the existing makes:-Voltas/Hitachi/ Carrier /copland/Emirson as approved by GE
Disconnection and taking out old defective Hermetically reciprocating sealed compresso as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vaccumnsing etc of capacity 5 TR for pakage AC plants of the existing makes:-Voltas/Hitachi/ Carrier /copland/Emirson as approved by GE
Material and labour for fabrication and installation of glow Sign board (640 cm x 91cm x 25cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having with intenal tube light fitting arrangement to open the flex/Acrylic board and suitable for mounting on wall/ gate complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
Material and labour for fabrication and installation of Sign board (240 cm x 91cm x 25 cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
Supply and fixing of hony comb frills ( of FRP cooling tower of any capacity by dismantling top and bottom honey comb frills size of frill as per site requirment, testing commissioning complete all as directed by Engr-in-charge.
Sahara Engineers
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
PAMS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .