Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC N0 15 ASHOK NAGAR MAIN ROAD MES ROAD 3RD CROSS STREET EAST TAMBARAM CHENNAI 600 059 | CHENGALPATTU | TAMIL NADU | 600059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.5 L+₹48,432 (1.15%)Rejected-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L2 | Rejected-AOC L2 | |
| 3 | L3₹42.5 L+₹55,792 (1.33%)Rejected-AOC 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L3 | Rejected-AOC L3 | |
| 4 | L4₹43.7 L+₹1.7 L (4.01%)Rejected-AOC NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM 603 102 KANCHEEPURAM DIST | KALPAKKAM | KANCHEEPURAM | TAMIL NADU | 603102 | L4 | Rejected-AOC L4 | |
| 5 | L5₹43.9 L+₹1.9 L (4.55%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Mar 2020, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
82413 SPECIAL REPAIRS TO SHIPS GALLEY AT VELLACHI UNDER AGE(I) NAVY CHENNAI
2020_MES_328131_1
CA NO CWE/NAVY/CHN/82413/E8 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
CHENNAI
Please ref tender documents
8 documents required · 8 mandatory
₹500
AGE(I) NAVY CHENNAI
₹90,000
Yes
9 May 2020
24 Feb 2020
31 Mar 2020
24 Feb 2020
30 Mar 2020
9 Mar 2020
25 Feb 2020 - 3 Mar 2020
Amount
CIVIL WORKS Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar complete all as specified and directed.
Material and labour for chequered cement concrete tiles 200 x 200 x 25mm thick / 300 x 300 x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and as directed.
Taking down existing cement roof treatment of any description of any thickness and removing the debris to a distance exeeding 500mtr but not exc 1000mtr complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with cement at the rate of 3.0 kg per sq. metre over cleaned surface, complete all as specified and directed.
Material and labour for providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in padding concrete, laid to uniform slope over roof slab, complete all as specified and as directed.
Material and labour for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces , including water proofing compound @ 2 % by weight of cement, finished fair and even without using extra cement all as specified and as directed.(Note: Water proofing compound will be measured and paid seperately as a supply only item)
Supply only integral water proofing compound all as specified and as directed.
Supply and laying 3mm thick APP polymeric water proofing membrane of 3 kg/sqm of black finished reinforced with non-woven polyester matt. with a thermo fusible finish laid over 1.2 kg/sqm bitumen grade 85/25 over compatible bitumen primer at the rate of 0.30 ltrs/Sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the ends and sealing applying two coats of 1.2 kg/sqm bitumen grade 85/25 all as per manufacturers instructions, over and including 10 mm thick cement mortar (1:3) plastering using with and including WPC @ 3% by weight of cement or as per manufacturers instructions and applying bituminous aluminium paint @ 0.10 litre/sqm over polymer membrane (As in roofs) , complete all as specified and as directed. (Note: Water proofing compound will be measured and paid seperately as a supply only item)
Material and labour for rendering 15mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces including water proofing compound @ 2 % by weight of cement, finished even and smooth without using extra cement all as specified and as directed.(Note: Water proofing compound will be measured and paid seperately as a supply only item)
Material and labour for providing plain cement concrete 1:5:10, type E2 using 40mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
Material and labour for rendering 25 mm thick plain cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in screed bed over sub base etc., complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises to a distance n. exc 2 kms outside MD land complete all as specified and as directed.
Material and labour for coloured joint free non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm and not exceeding 0.18 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including screed bed 15 mm thick in cement mortar 1:6 etc complete all as specified and as directed.
Material and labour for light shade coloured vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36sqm, in floors etc... in flooring including skirtings, set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including screed bed 15mm thick in cement mortar (1:6) etc... complete all as specified and as directed.
Material and labour for joint free 350 x 250 x 7mm thick / 450 x 350 x 7 mm thick coloured glazed ceramic tiles on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including 10mm thick backing coat in cement mortar 1:3 all as specified and as directed.
Removing building materials etc (other than spoil) to a distance of exceeding 1.5km but not exceeding 2km outside defence land, including loading unloading and stacking at the destination all as specified and as directed.
Cutting grooves in brick/concrete wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Taking down of chowkhats or frames not exceeding 1.5 sqm each (without taking off shutters from the frame) all as specified and as directed.
Taking down of chowkhats or frames exceeding 1.5 sqm and not exceeding 4 sqm each (without taking off shutters from the frame) all as specified and as directed.
Supply and fix solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with 19 x 19mm MS square tube EPDM rubber gasket weather seal to be provided throught the frame, the profile shall be mitre cut at two corners and jointed by inserted 2mm of 150mm long bracket of 15 x 15mm MS square tube inside the 19 x 19mm MS square tube and suitable screwed the door frame shall be fixed to the wall using PVC fasteners. A minimum of 6Nos screws to be provided for each frame all as specified and as directed. Note: The quoted rates are deemed to be included for cutting holes, providing concrete for hold fast and making good to the disturbed surfaces.
Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement all as specified and as directed.
Supply and fix powder coated ( Minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and as directed. (Note: Glass shall be measured and paid separately)
Supply and fix powder coated ( Minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, necessary hinges anodised aluminium snap beading, screws etc, complete all as specified and as directed. (Note: Glass and other filling materials in panels shall be measured and paid for separately)
Material and labour powder coated (Minimum thickness of powder coating 50 micron) anodised aluminium windows and ventilator shutters side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B2 100mm long (2Nos) suitable handles (1 No) complete all as specified and as directed.
Supply and fixing Aluminium grill of size 104 with 100 x 100mm fixed to aluminium windows or opening complete all as specified and as directed.
Supply and fixing sheet glass 4mm thick, ordinary quality, in squares, not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply and fix Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples all as specified and as directed
Supply and fix 12 mm thick Prelaminated particle board, prelaminated with both side decorative choice lamination, exterior grade, fixed with screws to timber frame work as in cup board shutters all as specified and as directed.
Supply and fix extruded aluminium handles fabricated type anodised 150 mm long complete all as specified and as directed.
Supply and fix extruded aluminium anodised barrel tower bolt of 150mm size fixed complete, complete all as specified and as directed.
Supply and fix aluminium alloy, anodised sliding door bolts with hasp, staple and fixing bolts, of extruded section or cast aluminium alloy and length of bolt 300 mm complete all as specified and as directed.
Supply and fix 125mm floor door stopper of aluminium alloy body ,with rubber bush complete all as specified and as directed.
Supply and fix door closer hydraulically regulated designation No 2 universal type, aluminium (die cast) body suitable for door shutter of 701 to 850 mm in width and of weight between 36 to60 kg and fixed all as specified and as directed.
Supply and fix vitreous china wash water closet pedestal pattern white of size 580mm with plastic water closet seat closed pattern with flat bottom cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed.
Supply and fix in repairs, 10 litre capacity, PVC flushing cistern, white, symphonic action type, low level, with in let, ball valve float and handle, PVC flush pipe, brackets etc , including brackets and 32 mm dia PVC flush pipe of 60 cms long, complete all as specified and as directed.
Supply and fix in repairs 32 mm dia waste fittings, brass chromium plated suitable for glazed ware basins etc with long screwed shank, flynuts, complete all as specified and as directed.
Supply and fix 32 mm bore high density polyethylene pipe (HDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
Supply and fix in repairs , PVC connections 15mm dia and 450mm long with brass nuts and washers at both ends suitable for wash basin/pillar complete all as specified and as directed.
Supply and fix in repairs 75 mm UPVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
Supply and fix in repairs, 15mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.
Supply and fix in repairs 15mm bore stop valves with flange cast copper alloy screwed down high pressure, with crutch or butterfly handle screwed both ends for 15mm iron pipe all as specified and as directed.
Supply and fix in repairs 15mm bore fancy type stop valves for shower with long shank and cup (concealed type) cast copper alloy screwed down high pressure,with crutch or butterfly handle screwed both ends for iron pipe and fixed all as specified and as directed.
Supply and fix in repair shower rose brass, chromium plated, of size 125 mm, with or without swivel joint, including fixing to 15 mm bore of pipe all as specified and directed.
Supply and fix in repairs stainless steel plate rack kitchen 1 mm thick of size 750 x 950mm with racks and shelf including bedding in cement mortar on to wall or including fixing cantilever brackets complete all as specified and as directed.
Supply and fix in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers including bedding in cement morter to dwarft wall or including fixing cantlever brackets and connecting union to pipe overall size 915 x 460mm bowl size 410 x 330 x 160mm complete all as specified and directed.
Taking down cement plaster on brick or stone walls including ceilings etc., including racking out joints, hacking for key scrubbing down with water and removing rubbish off the premises , removal and depositing serviceable materials where directed all as directed.
Material and labour for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6), finished even and smooth without using extra cement, complete all as specified and as directed.
Material and labour for 15 mm thick rendering in two layers 10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4 mixed with water proofing @ 2% by weight of cement with rough cast plaster finishes complete all as specified and as directed. Note :- WPC will measured separately
Material and labour for 15 mm thick rendering in two layers 10mm thick backing coat in CM 1:6 and 5 mm thick finishing coat in CM 1:4 mixed with water proofing @ 2% by weight of cement with finished surfaces fair and even complete all as specified and as directed. Note :- WPC will measured separately
Material and labour for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces of ceiling finished even and smooth without using extra cement all as specified and as directed.
Material and labour for preparation of newly plasteres surfaces of walls and applying three coats of white wash all as specified and as directed.
Material and labour for preparation of plastered or unplastered wall surfaces and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Material and labour for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
Material and labour for GI tubing medium grade 20mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor , including taking down old exisiting, complete all as specified and as directed.
Material and labour for GI tubing medium grade 25mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor , including taking down old exisiting, complete all as specified and as directed.
Material and labour for GI tubing medium grade 40mm dia bore with all fittings and fixing complete all wall, ceiling or laid in floor, including taking down old exisiting, complete all as specified and as directed.
Material and labour for Cutting chases in brick work, pinning in making good to facing where required and pointing to cement mortar 1:3 for concealed water tubing and making good for cutting not exceeding 10 cm girth,complete all as specified and as directed.
Taking down eaves gutters and rain water pipes of any size and descriptions including all fittings like heads, shoes, bends etc.. complete all as specified and as directed.
Supply and fix 110 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls, all as specified and directed.
Supply and fix 75 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls, all as specified and directed.
Supply and fix 110 mm dia bore PVC (SWR) bends any radius, all as specified and directed.
Demolition of stone slabs and tiles of any description and thickness in floors, skirtings, riser, treads etc…laid , bedded and pointed in any mortar all as specified and as directed.
Material and labour for Makrana white marble stone work, 18 to 20 mm thick, mirror polished as in kitchen platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including screed bed 15 mm thick in cement mortar (1:6) etc complete all as specified and as directed.
Supply and fix in repairs gun metal globe or gate valve, with iron wheel head, 40 mm dia bore of pipe, screwed both end for iron pipe, complete all as specified and directed.
Supply and fix in repairs gun metal globe or gate valve, with iron wheel head, 25 mm dia bore of pipe, screwed both end for iron pipe, complete all as specified and directed.
Supply and fix in repairs gun metal globe or gate valve, with iron wheel head, 20 mm dia bore of pipe, screwed both end for iron pipe, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cms and getting out in soft/ loose soil complete all as specified and directed.
Supply and fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction all as specified and as directed.
Supply and fix rotational moulded polyethylene water storage tanks 2000 ltrs capacity, three layer (cylindrical or vertical with closed top) hoisted and fixed in position, including dismantling the existing etc complete all as specified and directed.
Supply and fix rotational moulded polyethylene water storage tanks 500 ltrs capacity, three layer (cylindrical or vertical with closed top) hoisted and fixed in position, including dismantling the existing etc complete all as specified and directed.
Excavation over areas in hard/dense soil, not exceeding 1.50 metre deep and getting out complete all as specified as directed
Material and labour for providing plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in mass concrete for foundation filling including necessary use and waste of formwork, complete all as specified and as directed.
Material and labour for providing reinforced cement concrete M-30 using 20mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
Material and labour for providing reinforced cement concrete M-30 using 20mm graded stone aggregate as in columns,pillars, struts,piers,posts etc complete with joints to match all as specified and directed.
Material and labour for providing reinforced cement concrete M-30 using 20mm graded stone aggregate in beams cantilivers, bressummers, lintels over 1.5 mtr span all as specified and directed.
Material and labour for providing reinforced cement concrete M-30 using 20mm graded stone aggregate in chajjas all as specified and directed.
Material and labour for providing reinforced cement concrete M-30 using 20mm graded stone aggregate as in roof slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 250mm thick in hard/ dense soil complete all as specified and directed.
Removing excavated material exceeding 250m but not exceeding 500m and depositing where directed complete all as specified and as directed.
Material and labour for 15 cm thick (spread thickness) moorum/ red bajri, filling in floors or pavingd,levelled and rammed as required, complete all as specified and directed.
Material and labour for high strength deformed TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
All as per serial item No 89 here-in-beofre but 5 mm dia and over upto and including 10cm dia in stirrups, spacers and binders
Material and labour for Hardcore of gauge exc. 63 mm, deposited, spread and levelled in layers n exc. 150 mm thick, watered and rammed to a true surface using broken stone or aggregates all as specified and as directed.
Material and labour for machine cut kota stone slab flooring, 20-25 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade along with rubbing, polishing etc...over and including 15 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
Supply and laying of reinforced cement concrete pipe 200mm bore, class NP-2, tested and jointed with collars as per SSR Part-I clause 18.74.4 complete all as specified and directed.
Supply and fix 110 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors, including taking down existing pipes, all as specified and directed.
Supply and fix in repairs PVC (SWR) 125/110mm bore 'S' trap all as specified and directed.
Material and labour for brick work built in cement mortar 1:6 using fly ash bricks, modular type, straight or curved on plan exceeding 6 mtrs mean radius all as specified and as directed.
INTERNAL ELECTRIFICATION Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials for taking into Credit and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Taking down old light fittings sketch type/ box type complete with glass shade and lamp all as specified and directed.
Taking out old/ existing MCB DB SPN/TPN with MCB's complete by disconnecting all as specified and directed.
Taking down old sub main wiring with 2 runs/ 4 runs or 4/6/10 sqmm aluminium / copper cables including making good to disturbed surface all as specified and directed.
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 20mm dia (ISI marked) and accessories, concealed in wall / surface on ceiling, including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly excluding modular metal flush box and white cover plate with frame, switches, sockets, fan regulator etc as required suitable for modular type fitting/fixture, complete all as specified and as directed for the following:- Note: Supply only new sunken type pressed steel terminal box with plastic white cover plates with frame shall be measured and paid seperately. Make of cable :Plaza/Finolex/ Polycab/Anchor
One light point controlled by one switch
One fan/Exhaust fan point controlled by one regulator/ switch
One 3 pin 5 amps socket outlet on independant board
One 3 pin 15 amps socket outlet on independent board but with 4 Sqmm point wiring.
Sub main wiring with two runs of single core 2.5 sqmm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, with one run of 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor 1100 volts FRLS cable as earth continuity conductor and one run of suitable size non metallic rigid PVC conduit 25 mm dia and conduit accessories fixed to wall/roof/floor etc, in repairs complete all as specified and as directed. Note : (i) Two runs of main cable ,one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose. Make of cable :Plaza/Finolex/ Polycab/Anchor
Sub main wiring with four runs of single core 6 sqmm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, with one run of 6 sqmm single core PVC insulated unsheathed multistranded copper conductor 1100 volts FRLS cable as earth continuity conductor and one run of suitable size non metallic rigid PVC conduit 25 mm dia and conduit accessories fixed to wall/roof/floor etc in repairs complete all as specified and as directed. Note : (i) Four runs of main cable , one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose. Make of cable :Plaza/Finolex/ Polycab/Anchor
Supply and fix in repairs switch Modular 6 Amps 230 Volts one way switch, flush type, 1 module all as specified and directed.
Supply and fix in repairs socket Modular, 6 Amps, 230 Volts , flush type, 1 way complete all as specified and directed.
Supply and fix in repairs socket Modular, 3 pin 15 Amps, 230 Volts , flush type,complete all as specified and directed.
Supply and fix in repairs only electronic fan regulator step type for ceiling fan all as specified and directed.
Supply and fix in repairs ceiling rose, 3 phase PVC polycarbonate, 65 x 35 mm, isolated body, complete all as specified and directed.
Supply and fix Modular white cover plate with frame 2 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 3 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 4 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame 6 module complete all as specified and as directed.
Supply and fix Modular metal flush box 1/2 module complete all as specified and as directed.
Supply and fix Modular metal flush box 3 module complete all as specified and as directed.
Supply and fix Modular metal flush box 4 module complete all as specified and as directed.
Supply and fix Modular metal flush box 6 module complete all as specified and as directed.
Supply and fix in repairs MCB DB VTPN 8 way with 100 Amps TP, 25 KA MCCB as incomer complete in SS enclosure, vertical double door type,complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix in repairs MCB DB SPN 12 way complete in SS enclosure double door type, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix MCB TP, 415 Volts, 63 amps with 10 KA breaking capacity, in repairs complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix MCB DP, 415 Volts, 50/63 amps with 10 KA breaking capacity , in repairs complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix MCB SP, 230 Volts, 6-40 amps with 10 KA breaking capacity, in repairs complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Supply and fix LED Tube light fitting 1 x 18 W (4 feet) , trendy wall mounted batten with extruded aluminium housing and integrated LED driver etc… complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down existing fittings, complete all as specified and directed. MAKE: Crompton Cat Part No. LCTL-18-CDL or equivalent in Philips/ Surya /Wipro/ Bajaj/ GE
Supply and fix LED Tube light fitting 1 x 9 W (2 feet) , trendy wall mounted batten with extruded aluminium housing and integrated LED driver etc… complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down existing fittings, complete all as specified and directed. MAKE: Crompton Cat Part No. LCTL-9-CDL or equivalent in Philips/ Surya /Wipro/ Bajaj/ GE
Supply and fix energy saving new generation 10 W LED IP 65, Bulkhead luminaire with opal diffuser, complete all as specified and directed. MAKE: Bajaj/ Crompton/Wipro/ GE
Supply and fix single pole neutral enclosure with a two pin and earth plug and socket complete with one single MCB, 240 V, 20 amps, as in repairs, complete all as specified and directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
Disconnecting and taking down ceiling fan, cleaning, servicing, greasing and carrying out minor repairs and painting including MES numbering etc… and hanging back including connecting up with new suitable extension rod, complete all as specified and directed.
EXTERNAL ELECTRIFICATION Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified.for cable protection complete all as specified and directed. (Note: Only punned thickness of river sand shall be measured)
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with multi stranded aluminium conductor of size 3.5 core 50 Sqmm,laid in trenches including testing and commissioning , including taking down old existing, complete all as specified and as directed by Engineer-in-Charge.
Supply and laying LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with multi stranded aluminium conductor of size 2 core 10 Sqmm,laid in trenches including testing and commissioning , , including taking down old existing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED bollard garden light with LED 8W lamp stainless steel housing with clear acrylic cover in top section with IP65 protection,, including taking down old existing, complete all as specified and directed. MAKE: Crompton Model No : LBLTW-10-CDL or equivaent in Philips/ Surya/Wipro/ Bajaj/ GE as approved by AGE (I)
Material and labour for earthing complete with copper earth plate of size 300 x 300x 3mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 20 x 3mm copper strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal dust, salt, PCC M-15 type B1 in pit with precast RCC M-15 type B1 in cover reinforced with XPM not less than 4Kg per Sqm, test point etc, all as shown in electrical plate No 3 of SSR Part - I (2009) Specifications complete with necessary earth work in any type of soil, removal to a distance n.exc 50 m, including testing on completion, complete all as specified and as directed by Engineer-in-Charge. Note : The cost of excavation, earth work, PCC pit, CI cover, funnel, watering pipe, wire mesh, charcoal dust, common salt, GI pipe as protection to earth lead strip shall be deemed to be included in the quoted rate.
Material and labour for earth continuity conductor or copper strip 20 x 3 mm buried in ground/ fixed on wall/ drawn in 15 mm dia light grade GI pipe, complete all as specified and directed.
Cutting the existing road/hard standing for laying of pipes (45 cm width and 75 cm depth) and making good the disturbed surface by using PCC (1:4:8), type D-2 using 40mm aggregates at the top for a depth of 15 cm and remaining portion to be covered with excavated soil complete all as specified and directed.
Supply and fix pole mounting junction box (looping box) for bollard light for single phase internal size 103 x 103 x 73mm comprising of PVC connector and porcelain fuse cutout 6 Amps including mounting arrangements etc complete all as specified and as directed. Make: Sintex / Hansel / Spelsbary
Dismantling the existing unserviceable pipe and supply and laying in trenches fixed to wall/pole GI pipe light grade of size 50 mm dia for cable protection complete all as specified and as directed.
Supply and fix MCCB 4P 63 Amp 16 KA on exitsing panel complete all as specified and as directed. MAKE: L&T/ Legrand/ ABB/ Siemens/ Schneider
DJ Group
RAVI ENTERPRISE
S VENKATESAN
VIJAYALAKSHMI ENTERPRISES
lakshmibuilders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .