| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.4 L+₹5.5 L (21.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.2 L+₹8.3 L (32.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.4 L+₹8.5 L (32.6%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.1 L+₹9.2 L (35.5%)Rejected-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
14 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIJAY NEHRA
GE SATWARI
REPAIR/MAINT OF SUMMER COOLING AND HEATING APPLIANCE UNDER AGE E/M OF GE SATWARI
2021_MES_431188_1
GEJM-05/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SATWARI
₹80,000
Yes
17 Jun 2021
17 Mar 2021
16 Apr 2021
17 Mar 2021
14 Apr 2021
31 Mar 2021
60 days
Amount
Servicing of window type AC 1.5/2 TR capacity by washing complete unit & checking all electric connection/circuit for smooth functioning of AC at site complete all as specified and directed.
Servicing of split AC of 1.5/2 TR capacity by washing complete unit & checking all electric connection/circuit for smooth functioning of AC at site complete all as specified and directed.
Attending the complaints for window /split AC at site & tracing out fault , replacement of unserviceable/burnt parts of machine, all other items like water coolers deep freezer refrigerators, stabilizers & desert coolers shall be available in the MES workshop for repair (Items will be measured and paid under respective items). The complaint has to be addressed immediately
Supply only new rotary compressor single phase of capacity 1.5 TR in replacement to unserviceable compressor as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only new rotary compressor single phase of capacity 2 TR in replacement to unserviceable compressor as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only new reciprocating compressor of capacity 1.5 TR reciprocating type in replacement to unserviceable compressor as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only new reciprocating compressor of capacity 2 TR reciprocating type in replacement to unserviceable compressor as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only starting relay suitable for 1.5 TR/2TR capacity AC.
Supply only starting capacitor 80-100/100-120 mfd suitable for 1.5/2.0 ton capacity AC
Supply only running capacitor 36/50 mfd, 36/2,45/2,45/4, 45/6, 50/2,50/4,50/6 suitable for 1.5/2.0 ton capacity AC.
Supply only thermostat switch ISI Marked suitable for 1.5/2 ton capacity AC of existing make & type.
Supply only front grill suitable for 1.5/2.0 TR window AC of existing make/type.
Supply only motor three speed single phase , double shaft suitable for window type AC 1.5/2 ton capacity of existing rating/make & type.
Supply only motor single speed, single phase suitable for condensing unit ( outer unit ) of split type AC 1.5/2 ton of existing rating/make & type.
Supply only motor three speed single phase suitable for cooling unit (inner unit) of split type AC 1.5/2 ton of existing rating/make & type.
Supply only blower assy roller type along with bush for 1.5/2 ton split AC as per existing type/size.
Supply only new PVC fan blade/blower for 1.5/2 TR window/split AC as per existing type/size.
Material and labour for rewinding and repairing of fan motor suitable for AC upto 1.5/2.0 TR capacity with super enamelled copper wire of existing gauge complete all as directed.
Repairing defective PCB window/split type AC 1.5/2.0 Ton any type and refixing after repair.
Supply only new PCB for complete burnt or unserviceable PCB of window AC 1.5/2.0 TR of existing make & type .
Supply only new PCB for complete burnt or unserviceable PCB of split AC 1.5/2.0 TR of existing make & type .
Supply only new PCB card for complete burnt or unserviceable PCB card of inverter technology split AC 1.5/2.0 TR of any make & type .
Supply only new display unit for complete burnt or unserviceable display for split AC of any make & type .
Supply only magnetic contactor relay AC 230 Volts suitable for split AC 1.5/2.0 TR.
Supply only outdoor unit of air conditioner electric driven (single phase),220 volts of cap 1.5 Ton Hot and Cold type complete with all accessories as per existing make & type.
Supply only reversible valve in window/split AC 1.5/2.0 TR including making bypass system with copper tube/brazing work etc.
Taking down & Shifting of split /window AC 1.5/2.0 TR from one place to another by dismantling the unit from existing location and re-installing in the new loaction as directed by Engr-in-charge (Gas charging will be paid separately in ser item)
S & F in replacement of Capliery copper pipe of size 0/31 and 0/64 ,0/50 as directed by Engr-in-Charge
S & F in replacement of copper pipe of size 12.5 mm dia as directed by Engr-in-Charge
S & F in replacement of copper pipe of size 6.25 mm dia as directed by Engr-in-Charge
Supply only cooling coil of window type AC 1.5/2.0 TR matching with existing type & size all as specified and directed
Supply only condensing coil of window type AC 1.5/2.0 TR matching with existing type & size all as specified and directed
Supply only condensing coil of split type AC 1.5/2.0 TR matching with existing type & size all as specified and directed
Supply only outdoor unit of air conditioner electric driven (single phase),220 volts of cap 2 Ton Hot n Cold type complete with all accessories as per existing make & type.
S & F in replacement of MCB SPN 32 Amp "C" curve as directed by Engr-in-Charge.
Supply only new compressor in replacement of old unserviceable compressor sealed unit for refrigerator /deep freezercap 286/300/310/320 Ltrs as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only new compressor in replacement of old unserviceable compressor sealed unit for refrigerator /deep freezer cap 165/185 Ltrs as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only relay assy along with over load protection complete (PTCR) AC 230 volts suitable for refrigerator/deep frezer matching with existing make/type & size
Supply only thermostat switch suitable for refrigerator/deep frezermatching with existing make/type & size all as specified and directed
Supply only de-frost Timer suitable for refrigerator matching with existing type & size all as specified and directed
Supply only motor single phase suitable for double door Refrigerator matching with existing type & size all as specified and directed
Supply only PVC freezer shutter alongwith frame 165 to 320 Ltrs capacity refrigerator & matching with the existing type/size all as specified and directed.
Supply only freezer/cooling coil for refrigerator/deep frezer cap 165 to 320ltrs matching with existing type & size all as specified and directed
Supply only condensing coil of refrigerator/deep frezer cap 165 to 320 ltrs matching with existing type & size all as specified and directed
Supply only compressor sealed unit for water cooler cap-40/80 ltrs as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only compressor sealed unit for water cooler cap-60/120, 150/150 Ltrs as directed by Engr-in-Charge. ( Note Charging of gas shall be paid separately under respective item).
Supply only fan motor 1/35 HP, 950 RPM suitable for water cooler cap 40/80 ltrs existing make & type complete all as directed.
Supply only fan motor 1/10 HP, 1350 RPM suitable for water cooler cap 60/120 to 150 ltrs existing make & type complete all as directed.
Supply only starting capacitor 40/60, 80/100 MFD for water coolers complete all as directed.
Supply only running capacitor 10/15 MFD for water coolers complete all as directed.
Supply only indoor unit complete of air conditioner electric driven (single phase),220 volts of cap 2.0 Ton Hot and Cold type complete with all accessories as per existing make & type.
Supply only thermostat ISI Marked for water cooler matching with existing make/type/size complete all as specified and directed by Engineer -in-charge.
Supply only blower fan blade of water cooler matching with existing size/type complete all as directed by Engineer-in-Charge.
Supply only starting relay assembly with OLP for water cooler 40/80 ltrs matching with existing type/size complete all as specified and directed by Engineer -in-charge.
Supply only starting relay assembly with OLP for water cooler of size 150/150 ltrs matching with existing type/size complete all as specified and directed by Engineer -in-charge.
Supply only push cock chrominum plated existing type, size-15mm suitable for water cooler complete all as specified and directed by Engineer -in-charge.
Supply only drian pipe existing type/size suitable for water cooler complete all as specified and directed by Engineer -in-charge.
M& l for replacement of RO+ UV based water purifier filter of any make and any size , like pre filter,carbon block , sedimantion filter ,PCB ,SV and ub filter complete all as specified and directed by Engineer -in-charge.
Supply only Fan motor of desert cooler 220/240 volts, 50 Hz, 1 phase 3 speed, 180 W and testing complete all as specified and directed by Engineer -in-charge.
Supply only submersible pump for desert cooler operational on 230 volts AC supply & testing complete all as specified and directed by Engineer -in-charge.
Supply only desert cooler electric driven (single phase), steel body size-26X26X34 inch and tank height 7" made out of heavy gauge galvanized iron sheets and complete all as specified and directed by Engineer -in-charge.
Supply only capacitor 3.15 to 4 MFD complete all as specified and directed by Engineer -in-charge.
Supply only indicator lamp 230 volts 50 Hz supply suitable for desert cooler complete all as specified and directed by Engineer -in-charge.
Supply only PVC water distribution pipe incl PVC elbow & distributor suitable for desert cooler as existing size/type complete all as specified and directed by Engineer -in-charge.
Supply only aluminium plate for mounting controls etc suitable for desert cooler as existing size/type all as specified and directed.
Supply only thick wood wool pads suitable for desert cooler as existing size/type complete all as specified and directed by Engineer -in-charge.
Supply only single pole and neutral enclosure with a two pin and earth plug and socket complete all as specified and directed by Engineer -in-charge.
Rewinding of voltage stabilizer single phase AC 230 volts 50 Hz with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size 5 KVA complete all as specified and directed by Engineer -in-charge.
Description all as per Srl item No 70 here in before but of capacity 2/3 KVA.
Description all as per Srl item No 70 here in before but of capacity 1 KVA.
Supply only voltmeter suitable for voltage stabilizer as existing size/type all as specified and directed.
Supply only ampere meter suitable for voltage stabilizer as existing size/type/cap all as specified and directed.
Supply only socket 16 Amp suitable for voltage stabilizer as existing size/type complete all as specified and directed by Engineer -in-charge.
Supply only relay suitable for voltage stabilizer 5KVA as existing size/type all as specified and directed.
Supply only circuit plate suitable for voltage stabilizer 5KVA as existing size/type complete all as specified and directed by Engineer -in-charge.
S and F automatic voltage stabilizer wall mounted type in repalcement of complete burnt stablizers of single phase AC 230 volts 50 Hz Input range 90-290V and output 220-240V with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size 5 KVA complete all as specified and directed by Engineer -in-charge.
Supply only indoor unit complete of air conditioner electric driven (single phase),220 volts of cap 1.5 Ton Hot and Cold type complete with all accessories as per existing make & type.
S and F automatic voltage stabilizer wall mounted type in repalcement of complete burnt stablizers of single phase AC 230 volts 50 Hz Input range 90-290V and output 220-240V with super enameled copper wire of suitable gauge to match with the existing one including all related work and testing complete of size 2 KVA complete all as specified and directed by Engineer -in-charge.
Supply only connector suitable for voltage stabilizer 5KVA as existing size/type all as specified and directed complete all as specified and directed by Engineer -in-charge.
S&F in repair energy efficient 5 star rated electric storage water heater of capacity 50 ltrs vertical type 220 volts complete all as specified and directed by Engineer -in-charge.
Supply only input/output/push switch suitable for voltage stabilizer 1/2/3/ 5KVA as existing size/type all as specified and directed.
Supply only PVC copper conductor cable flexible 3X1.5 Sqmm complete all as specified and directed by Engineer -in-charge..
Supply only PVC copper conductor cable flexible 3X2.5 Sqmm complete all as specified and directed by Engineer -in-charge..
Supply & charging refrigerant gasR-134-A/R-12/R-22/R-410 in the air coditioner, water cooler,refrigerator of any make and capacity/size/type including testing and detecting leakage with nitrogen gases and vacuum the system , replacement of copper filter etc complete all as specified and directed by Engineer -in-charge..
Taking down carefully storage type water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections, repairing in workshop and after repair hanging to its on original position all as directed by Engineer-in-Charge for geyser of cap acity 25/50 ltrs. Note : Non return valve, element PVC/Copper connections, cable, glass wool and thermostat etc shall be measured separately.
M & L for de-scaling assy and cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc by using the brush / chemical as directed by Engineer-in-Charge for geyser of capacity 25/50 ltrs.
M & Lfor leakage arresting of inner copper/steel tank/syphon assy by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc refixing the same in position and carrying out testing for proper functioning and making good surface all as directed by Engineer-in-Charge for geyser of cap acity 25/50 ltrs.
Supply & replacement of heating element at complaint site any type (triangular/round/Z) of storage type water heater of compatible type including making all connections and removal of old unserviceable elements of any type capacity 2.0 Kilo Watt ISI Marked all as directed by Engr-in-Charge.
Description all as per Srl item No 90 here in before but of size 1.5 KW
Supply & replacement of heating element in built in asseblly at complaint site existing type for storage type water heater of compatible type for Bajaj GPV 25 , Racold,Venus including making all connections and removal of old unserviceable elements of any type capacity 1.5/2.0 Kilo Watt ISI Marked all as directed by Engr-in-Charge.
Supply & fixing in replacement thermostat ISI Marked for electric water heater storage type of cap-25/50 ltr suitable for AC 230 volts of any type.
Supply and fix fusible plug suitable for 25/50 litre capacity storage type water heater including provn of necessary GI fittings removal of existing valves.
Supply and fix drain plug suitable for 25/50 litre capacity storage type water heater including rubber washer etc.
Supply and fix pressure release valve lever type suitable for 25/50 litre capacity storage type water heater as per sample including rubber washer etc.
Replacement of water inlet and outlet assembly existing type & size with rubber gasket for 25/50 ltrs capacity electric driven water storage heater with provn of housing thermostat assembly heating element fixing arrangement nut bolts and washers etc. incl taking out old unserviceable complete all as specified and directed.
S&F in repair energy efficient 5 star rated electric storage water heater of capacity 25 ltrs vertical type 220 volts complete in all respect .
Supply & fixing in replacement water storage inner tank of steel for 25 ltrs capacity, with provn for fixing 15mm dia galvanized air release valve all as specified and directed .
Supply & fixing in replacement water storage inner tank of steel for 50 ltrs capacity, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply & fixing in replacement of heavy duty PVC connection 450mm large (18”) suitable for connection 15mm bore stop cock /GI tubing including brass nuts, washers complete on both ends .
Supply & fixing in replacement of heavy duty PVC connection 600mm large (24”) suitable for connection 15mm bore stop cock /GI tubing including brass nuts, washers complete on both ends .
Replacement of indicator lamps existing type & size suitable for AC 230 volts singe pole 50 Hz including electric connections and testing complete all as specified and directed.
Supply & fixing in replacement MCB SP 20 Amps "C" curve 240 volts.
Supply & fixing in replacement thermal cut out Bimetallic disc type with snap action switch, with operator below the boiling point i.e. 90+ 6˚C with manual reset.
Supply and fixing in replacement plug top 15 Amps 3 pins.
Supply and fixing in replacement metal plug top round type 15 Amps 3 pins as directed by Engr-in-charge.
Supply and Fixing Glass wool suitable for water storage geyser of any cap.
M & L for foam heat insulation of black colour for AC Copper pipe complete as directed by Engr-in-charge
S&F in replacement of three core copper cable 3 x 6 sq mm FRLSH insulated Unsheathed stranded copper conductor cable 1100 Volts grade complte all as specified and directed.
M& l for Disconnecting and taking down old unsv soler panel (flat collector plate ) in any position and refixing the same after repair of its original position as directed by Engr-in-charge (Note Items will be measured and paid under respective items).
M & l for replacement of solar panel plate as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M & l for replacement of old unsv thermal insulation including aluminium cladding from tank as directed by Engineer-in-Charge
M& l for replacement of GI tubing of size 15 mm to 25 mm bore with providing 25 mm thick uniform glass wool fiber having density 48 kg per Cum with using aluminium foil as directed by Engr-in-Charge
M& L for de-scaling of solar water heater of Cap 100 to 400 LPD and cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc by using the brush / chemical as directed by Engineer-in-Charge
M& L for replacement of Evacuated tubes as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M& L for replacement of solar glass tubes as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M& L for replacement of tube holder as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M& L for replacement of copper solar heat pipe as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M& L for replacement of borosilicate glass solar vaccum tube as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M& L for replacement of insulated steel Tank as per Existing make and size of solar water heater of Cap 100 to 400 ltr as directed by Engineer-in-Charge
M& L for replacement of solar water heating element of size 3000 to 4000 Watt as directed by Engineer-in-Charge
M& L for replacement of Air realese valve with Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
BMMJ TRADERS AND ENGINEERS
M/S S K Electricals Regd
Prakash Trading Corporation
Allied Technologies
SATISH AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .