| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹31.5 L+₹2.1 L (7.17%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance NOT REASONABLE | |
| 3 | L3₹33.0 L+₹3.5 L (12.0%)Rejected-Finance A 303 SHREE KRISHNA COMPLEX CO OP HSG SOC LTD WESTERN EXPRESS HIGHWAY OPP NATIONAL PARK BORIVALI E MUMBAI 400066 | MUMBAI SUBURBAN | MAHARASHTRA | 400066 | L3 | Rejected-Finance NOT REASONABLE | |
| 4 | L4₹33.0 L+₹3.6 L (12.2%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance NOT REASONABLE | |
| 5 | L5₹33.2 L+₹3.8 L (12.8%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L5 | Rejected-Finance NOT REASONABLE |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
SPL REPAIRS STRUCTURAL MEMBERS, ROOF AND OTHER CONNECTED ITEMS OF STAFF LIVING ROOMS OF BLDG NO P-41 (FGH), CONSTRUCTION OF MT SHED (60 FEET X 32 FEET) AND PROVN OF EASY DRY HANGER UNDER AGE B/R(W) UNDER GE(W) COLABA, MUMBAI
2024_MES_668290_1
8914/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹98,000
Yes
3 Dec 2024
30 Aug 2024
23 Sept 2024
30 Aug 2024
21 Sept 2024
14 Sept 2024
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L in repairs to replace old decayed timber( including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any height all as specified and directed.
S&F 0.63mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) all as specified and directed.
M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, primer application and applying two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications over and including padding of cement concrete Type B1, 1:2:4 (20 mm graded stone aggregate)40mm average thick on RCC roof surfaces and all other similar works complete all as specified and directed.
M&L plastering 20-25mm thick (Avg) ready-mix epoxy based Polymer modified cement mortar in two coats, 15mm base coat and subsequent finishing coat with and including curing as per manufacturer's instruction all as specified and as directed.
M&L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any height all as specifed and direcetd.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, bent to any shape etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) all as specified and as directed.
Dismantling of ceiling board (Plup insulation or insulation etc) or insulation board any thickness including cover fillet and grid frame work all as specified and directed.
M&L for GI powder coated frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
M&L 8 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 605 X 605 mm grids all as specified and directed. Note:- Frame work for ceiling shall be measured and paid separately.)
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/ columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 25 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) Note: thickness shall be measured excluding plaster)
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed.. (All loose unsound and cracked concrete shall be removed out side MD land) (Note: thickness shall be measured excluding plaster.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 60 mm average depth including saw-cutting of all edges making square shoulders of the cavities including complete all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) Note: thickness shall be measured excluding plaster.
Cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry and applying two coats of epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer as approved by the Engineer-in-Charge for old and new reinforcement any dia all as specified and as directed. Note : - Length of reinforcement bars cleaned of rust all around shall be measured for payment.
M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height all as specified and directed.
Demolition of Cement concrete (reinforced) of any description and in any position not otherwise specifically provided all as specified and directed.
M&L reinforced cement concrete 1:2:4, type B0 (using 12.5mm graded crushed stone aggregates) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likes all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height all as specified and directed.
M&L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed
Providing and placing in position micro-concrete, grade M40, which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion, thickness of section upto 75 mm all as specified and as directed by the Engineer in charge (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument and including necessary form work)
Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form work all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and as directed.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water all as specified and as directed.
M&L 15-20mm thick Ready Mix Plaster in single layer mixed with liquid waterproofing compound on other than fair faces of brick wall or concrete surfaces, (upto 05 storeys of bldgs) including use of scaffolding all as specified and directed. Note :- Liquid water proofing compound will be measured and paid seperately as supply only.
Supply only liquid water proofing compound all as specified and as directed.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and as directed.
Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface imperfections, protrusions, loose concrete & filling of cracks using SBR latex modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement all as specified and as directed.
M&L for PCC type B- 2, 1:2:4 (using 40mm graded crushed stone aggregate) 75 mm thick in floors all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and as directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and as directed.
M&L for applying two coats of Acrylic Elastomeric Waterproof Coating of weather proof paint (Rain coat), over a coat of primeseal or equivalent wall primer on new surface all as specified and as per manufacturer's instruction.
M&L for complete removal of existing treatment and applying two coats of Acrylic Elastomeric Waterproof Coating of wheather proof paint (Rain coat), over a coat of primeseal or equivalent primer on prepared surfaces all as specified and as per manufacturer's instruction.
M&L for preparation of old painted wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and as directed.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. .
M&L for preparing surfaces of battens, any size and spacing, and treated all over with two coats of creosote (measured overall on one side only, spaces not deducted) including scafoldings of any height all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint all as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, zinc primer all as specified and as directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removal of rubbish off the primises out side MD land all as specified and as directed.
M&L Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles all as specified and directed.
M&L rendering 10 mm thick plaster on fair faces of brick work in CM (1:4) all as specified and directed.
M&L Glazed ceramic tiles in vertical surface 600x300x7mm/450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shades of tiles all as specified and directed.
M&L non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.36 Sqm. in floors laid over 15 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes all as specified and as directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified and as directed.
M&L Vitrified Ceramic tiles (dark shade) 10 mm thick square/ rectangular polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site out side of MD land all as specified & directed.
M&L for machine cut, polished cudappah stone work 18- 20 mm thick (table rubbed and polished) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in kitchen platform, flooring and all other similar works, including laying over 15mm thick cement mortar (1:6) all as specified and as directed.
M&L granite (of any approved colour) 18 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, flooring, cill and all other similar works all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with cement all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exc 1.5 sqm each all as specified and as directed.
S&F factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified and directed.
S&F 15 micron coloured aluminium anodised grill design No DG-117, 10 mm thick including F Sections all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any height all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint all as specified and as directed.
Demolition of cement concrete in ground floor & paving nexc 15 cm thick (below or above GL) unreinforced all as specified and directed.
M&L PCC 1:2:4, type B2 ( using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and directed.
M&L for crushed sand filling under precast interlocking paver blocks and all other similar works all as specified and directed.
M&L rubber moulded glossy finished precast concrete interlocking paver block of any shape and size confirming to IS 15658 -2006 of 60 mm thickness, M-35 Grade laid over sand cushning including compaction of paver blocks using surface vibrator all as specified and directed. Note :- Sand cushioning shall be paid separately under relevant item.
M&L for taking down and refixing of interlocking tiles including prepration of sub base and also including 25mm thick sand cushion including watter and ramming (Compacted) and joints filled with sand all as specified and directed.
M&L for precast cement concrete louvers and jallies 40 mm thick, fixed over boundry walls using two Nos vertical members of size 100 x 90 x 800 mm height and one Nos member surmounted over vertical members of jalli (like ropes of the same materials) including all moulding all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment along external wall below concrete or masonary apron using chemical emulsion at the rate of 2.25 literes per linear metre including drilling and plugging holes etc in apron all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment for treatment of soil under existing floors using emulsion at the rate of one litre per hole, 300mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor all as specified and directed.
Providing and injecting chemical emulsion using chlorpyriphos 20 percent EC with 1 percent concentartion for post constructional Anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litre per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same all as specified and directed.
S&F 15 mm dia bore fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, or for brass ferrule all as specified and as directed.
S&F 15 mm bore chromium plated Angular stop valve with wall flange of cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality suitable for hot and cold supply all as specified and directed.
S&F in repairs vitreous China squatting pan, ' Orissa patteren, size 580 x 440 mm white, with integral foot rests (excluding flushing cisteren and flush pipe) including taking down existing squating pan all as specified and directed. M
S&F in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of any size all as specified and directed.
S&F urinals flat back with integrated EFS of size 355x340x535mm in snow white including each and all acessories all as specified and directed.
S&F Vitreous china urinal partition white of size 310x700 mm terminating about 40cm above floor line, fixed in repairs all as specified and directed.
S&F for 5 mm thick Saint-Gobain modi guard ultra looking mirror, having long lasting film suitable for bathroom including hidden studs all as specified and directed.
S&F Brass CP pillar cock with extension body including all necessary fittings screwed down for iron pipe for Wash Hand Basin all as specified and directed.
S&F in repairs vitreous China wash basin white, flat back, size 580X450 mm including cutting for pinning in ends of brackets all as specified & directed.
M&L PCC in roof kerbs or mud stops, rounded or chamfered on edges type B1, 1:2:4 (using 20mm graded crushed stone aggregate) all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm in hard/dense soil all as specified and directed.
S&F structural steel work in tubular/square tube trusses including special shaped washer, gusset/bearing plate using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 all as specified and directed.
M&L Brickwork with sub class ‘B’ bricks, built in CM 1:4 , straight or curved on plan exc 6m mean radius all as specified and directed.
M&L 12 mm thick ready mix plaster in single layer on brick wall or concrete surfaces including making groove of appropriate size, on other than fair faces of concrete/brick surfaces (internal surface) and finished surfaces even & smooth without using extra cement all as specified and directed.
S&F Pulley operated clothes drying system consisting of anodized Aluminium pipes, each of outer dia 22 mm and inner dia 19.8 mm. Pulleys made up of delrin with rope guide mounted on channel pair of length 24” (distance between two pipes is adjustable) Locking system to hide rope knot Channel to be mounted or fixed with self-tapping screws provided in kit. Rope will be polyester braided undyed of 4mm dia (For 9 feet) all as specified and directed.
S&F Pulley operated clothes drying system consisting of anodized Aluminium pipes, each of outer dia 22 mm and inner dia 19.8 mm. Pulleys made up of delrin with rope guide mounted on channel pair of length 24” (distance between two pipes is adjustable). Locking system to hide rope knot Channel to be mounted or fixed with self-tapping screws provided in kit. Rope will be polyester braided undyed of 4mm dia (For 7 feet) all as specified and directed.
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete including fittings such as switches, sockets, ceiling rose, pendent holders etc and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, all as specified and directed.
Taking down carefully copper/aluminum submain wiring & Cables complete including all fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed
M&L Sub main wiring with two run of 6 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 6 sq mm green colour wire as earth contuinity conductor connected to common earth dolly concealed including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures all as specified & as directed by engr-in-charge Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduite shall be measured as one length.
Supplying, laying, commissioning & testing LT underground cables 25 Sqmm X 3 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor including necessary Lugs and ferrols all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required.
Supplying, laying, commissioning & testing LT underground cables 16 Sqmm X 2 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required. Note : Rate inclusive of aluminium Lugs and furrol used in cable connection.
M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, concealed with accessories and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including cover plate mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately .
All as per Srl item No.85 here in before but for Ceiling fan point controlled by one switch.
All as per Srl item No.85 here in before but for socket outlet point 5 Amp on same board.
All as per Srl item No.85 here in before but for socket outlet point 5 Amp on Independent board.
All as per srl item No 85 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified and directed.
All as per serial item No 85 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. Note: Earthing wire should also be of 4 Sqmm.
M&L Point wiring with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit/ casing caping (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for concealed boxes and for concealed conduit wiring with all fittings and accessories including modular cover plates as required with and fix conecaled 1.2 mm thick pressed steel modular sunken box, suitable for fixing moduler switch socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point controlled by one modular switch, 1 way 6/10 amps, 1 module.
All as per serial item No 1 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified.
S&F modular switch 1 way 6 A module 230/250 volt , AC supply, ISI Marked, with white cover plate with frame and PVC Box all as specified and directed.
S&F modular switch 1 way 16 A module 230/250 volt , AC supply, ISI Marked, with white cover plate with frame and PVC Box all as specified and directed.
S&F modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame and PVC Box complete all as specified and directed.
S&F switch piano (ISI marked) Single pole 240 volts, 5 Amps all as specified and directed.
S&F socket (ISI marked) 2/3 pin and 5 Amps, flush type, 240 volts all as specified and directed.
S&F switch socket combination (ISI marked) 2/3 pin and 5/15 Amps, flush type, 240 volts all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed.
Taking down and refixing of ceiling fan (old fan) and connecting up including provision of cable from ceiling rose or connector and fan Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, replacement of defective parts and replacing it with new one including aluminium blades of superior quality, canopies and bearing etc. in order to make ceiling fan smooth in operation with taking down fan, sealing cable end, dismantling romoving and hanging fan with rod of required length and proper hook and blades and removing fan and blades to store all as specified and directed. Note: Connection should be made neatly using two core white flexible cable.
S&F Emergency LED Batten lights fitting 1x 20W, 220V, AC decorative box type, bright white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wall with 2 nos PVC block of suitable size all spcifided and directed. Note: Connection should be made neatly using two core flexible cable.
S&F in repairs 20 watt LED, 6500 K, 4 feet long fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing all as specified and directed Note: Connection should be made neatly using two core white flexible cable.
S&F in repairs LED lights fitting 1x 10W, mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, AC decorative box type, bright white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wall with 2 nos PVC block of suitable size all spcifided and directed. Note: Connection should be made neatly using two core white flexible cable.
S&F in repairs LED security Building light LED 45 Watt, pressure die cast aluminum housing, heat resistant glass, IP 65/66 protection, better optics for uniform distribtion with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed. NOTE : Rate quoted should be inclusive of connecting building security light to switch with 2.5mm 3 core flexible cable
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including 20 watt white LED bulb all as specified and directed.
S&F MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed.
S&F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed.
S&F in repairs MCB DP, 240 Volts, 32 to 63 Amps, 10 kA rupturing capacity 'C' series all as specified and directed.
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series all as specified and directed including taking down old one.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's all as specified and directed.
S&F in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting all as specified and directed. Note: MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note: Copper thimble shall be used for connection of cable .
S&F in repairs MCB Distribution board , 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways , fixed on wall/ wooden board of 2mm thickness duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed.
S&F in repairs MCB TPN, 415 Volts, 63 Amps, 16 kA rupturing capacity 415 Volts all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead Strip of size 25X4 mm by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised GI of size 4 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
ASHOK CONSTRUCTION (BID ID -3104245)
Nilesh Construction (BID ID -3103895)
Unitech Enterprises (BID ID -3102786)
HINDUSTAN BUILDERS (BID ID -3101174)
M K ENTERPRISES (BID ID -3105294)
Mayur Enterprises (BID ID -3101905)
GANGAJAL (BID ID -3099725)
Bidder Name
Unitech Enterprises
HINDUSTAN BUILDERS
Nilesh Construction
ASHOK CONSTRUCTION
Mayur Enterprises
GANGAJAL
RUPESH CONSTRUCTION CO
M K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .