Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
27 Sept 2022, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
MAINTENANCE REPAIR TO EXTERNAL WATER SUPPLY DG SET OLD PIPE LINE INCLUDING REPLACEMENT OF GATE SLUICE VALVE REPAIR OF VALVE PIT AND PERIODICAL MAINTENANCE AND SERVICING OF STP AND COOLING APPLIANCES AT AF STN INDAUR UNDER AGE EM AF RAJOKRI OF GE AF G
2022_MES_548726_1
CA NO GE/GUR-/NIT-34/2022-23
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹75,000
2 Dec 2022
30 Aug 2022
29 Sept 2022
30 Aug 2022
27 Sept 2022
13 Sept 2022
Amount
M & L for comprehensive maintenance of electric geyser ,storage type 230 volts single phase AC ,25/35/50 lts capacity and descaling of inner tank of geyser ,insluding brazing /welding if required ,replacement of worn out parts,reassembling and refixing on site ,including preparation of surface of geyser and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and as directed
S&F in replacement of geyser assembly suitable to fix thermostate , heating element as of the existing size including six nos. of clamps with bolts and nuts etc .complete all as specified and as directed
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and as directed .
S&F in replacement of heating element 1500 watt capacity triangular type complete all as specified and as directed
S&F in replacement of thermostate suitable for storage type water heater complete all as specified and directed.
Supply and fix stainless steel tank for 25 ltr storage type water heater complete all as specified and as directed
Supply and fix Copper tank for 25 ltr storage type water heater complete all as specified and as directed
S & F replacement PVC connection pipe with synthetic coating & washer suitable for hot /cold water of geyser complete all as specified and directed.
S&F in replacement of new indoor unit of split AC of capacity 1.5Ton with compitable for existing out door unit from authorized dealers of company complete all as specified & directed.
S&F in replacement of new indoor unit of split AC of capacity 2 Ton with compitable for existing out door unit from authorized dealers of company complete all as specified & directed.
S&F in replacement of new outdoor unit of split AC of capacity 2 Ton with compitable for existing out door unit from authorized dealers of company complete all as specified and as directed Note for item No 09 to 11 : Only one unit can be replaced either out door/ indor and unserviceable unit shall be taken over by MES and will be dispossed off after completion of BER Process.
M &L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manutatuer with high pressure pump of 2 Ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and as directed.
M &L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manutatuer with high pressure pump of 1.5 Ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and as directed
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified and as directed
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC complete all as specified and as directed
M&L for detection/rectification of leakage of gas in the system Through with NDT test and gas charging in the system with appropriate quantity of gas asper OEM Recomentation including testing for smooth functioning of Split AC of capacity 1.5 Ton complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is measured and paid separately.
M&L for detection/rectification of leakage of gas in the system Through with NDT test and gas charging in the system with appropriate quantity of gas asper OEM Recomentation including testing for smooth functioning of Split AC of capacity 2 Ton complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is measured and paid separately.
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and as directed
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed
S & F of Repair to compressor off size of existing makes and capacity for W/T and split type AC 1.5 Ton capacity complete all as specified and as directed
S & F of Repair to compressor off size of existing makes and capacity for W/T and split type AC 2 Ton capacity complete all as specified and as directed
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1.5/2 Ton capacity complete all as specified and as directed.
S & F of Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified and as directed
S&F in replacement of rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified and as directed
S&F in replacement of rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity complete all as specified and as directed
S&F in repair /replecement compressor reciprocatng type suitable for 1.5 Ton capacity single phase, 230 Volt, 50 Hz split/ window type airconditoner in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and as directed.
S&F in replecement compressor reciprocating type suitable for 2.0 Ton capacity single phase, 230 Volt, 50 Hz split/ window type air conditoner in and including refrigerant gas filling up to required level complete all as specified and directed.
S&F in replacement of Evaporator coil 1.5/2 Ton complete all as specified and as directed.
S&F in replacement of Suction/Discharge valve complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and as directed.
S&F in replacement of Copper tube cover complete all as specified and as directed
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and as directed
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and as directed. Note :- Rate quoted by contractor should include making the distrub surface as this (plastering & white washing & painting with same)
M & L for carry out Servicing Oiling,Greasing and Cleaning of water cooler of capacity 40/80 ltrs from authorised rep of service engineer from the manufactuer with high pressure pump,checking of defects/leaking and adjusting setting to work and testing complete all as specified and directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 ltr complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of BOQ (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is measured and paid separately.
S&F of compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.
M&L in replacement of starting relay and overload relay suitable for existing size and make water coolercomplete all as specified and as directed.
M&L in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
M & L for dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed.
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler/AC/Ref or deep freezer complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
M & L for Repair and maintenance, refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and as directed.
S&F in repair replecement compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator in and including refrigerant gas filling up to required level complete all as specified and as directed.
S & F of thermostate switch for refrigerator any make & capacity complete all as specified and as directed.
M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screw s etc testing , complete all as specified and as directed.( NOTE: (i) Spare parts like bearing,capacitor,bushes if required shall be measured and paid separately as supply only. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts.
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fans 400 mm /450mm sweep
Supply only ball bearing suitable for the following fans : Make :-NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fan 400 mm sweep
Supply and fix in repair capacitor 2.5 mfd,400 volt ,50 hz all as specified and as directed.Make : Tibcon
Supply and fix in repair capacitor 4 mfd,400 volt ,50 hz all as specified and as directed Make : Tibcon
M & L for Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size 80 to 100 mm Bore of any description such as CI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed.
All as per item No 57 above but for upto 50mm dia pipe line.
Note for item No 57.00 & 58.00:- (i) Complaint shall be notified to contractor on mobile phone. Hence, it is mandatory to mention his mobile No. while quoting submitting the performance guarranttee
ii) Complaint shall be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 12 hours after notification, failing which Rs 100/- rate per day per complaint shall be recovered
iii) Completion report of the complaint shall be given in writing and recorded in the register.
iv) Rates quoted shall be deemed to include the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule
Attending leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified. Note: bolts,nuts and washers shall be paid under relevant items of schedule
Demolition of existing valve pit chamber , M&L for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and as directed.
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as specified and as directed by Engineer-in-charge.
100 mm dia
80 mm dia
S & F of CI Specials/fittings including breaking/taking out defective DI/CI specials for spigot and socket end for CI mains upto 100 mm dia complete all as specified and as directed
Supply and fix in replacement of fully automatic star delta starter suitable for 10-20 HP pump motor set, AC 440 V 50 Hz with single phase preventor , over current and short circuit protection Built in voltmeter, ammeter complete all as specified. MAKE: L&T / BCH /Siemens .
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 80 mm bore etc complete all as specified and as directed
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 100 mm bore etc complete all as specified and as directed
Supply and fix in replacement cast iron flanged drilled heavy duty Non Retrun valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers etc of size 50 mm bore complete all as specified and as directed
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and as directed
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 100mm dia bore complete all as specified and as directed
M& L for complete dewatering and cleaning of underground sump of capacity 50K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable complete all as specified and as directed
M& L for complete dewatering and cleaning of underground sump of capacity 10K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable complete all as specified and as directed
comprehensive maintenance & repair of Hydropneumatic system (Make: Grund Fos) checking of motor, Well Vent Air Realase Valve vertical turbain Pump, Water Meter ,ASME Pressure Relief valve Including Replacement of air water control unit complete all as specified and as directed
M&L for rewinding of electric motor upto 15 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed
M&L for rewinding of electric motor 3 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed
supply & fix in replacement of veriable frquency drive (VFD) unit of Hydropneumatic system Make GrundFos complete all as specified and as directed
M& L for Comprehensive maintenance & servicing of fillteration plant installed at pump House no 1 including cleaning of Pual media fillter, Carbon activated fillter complete all as specified and as directed
M&L for repair of water level indicator with magnetic type sensor probs complete all as specified and as directed
Supply and fix of Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 25mm dia bore complete all as specified and as directed
Supply and fix of Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 40mm dia bore complete all as specified and as directed.
Supply and fix of CPVC Gate valve OF size 20 mm dia bore including material complete all as specified and as directed
Supply and fix of CPVC Gate valve OF size 25 mm dia bore including material complete all as specified and as directed
Taking down old U/S any type /capacity gate valve complete all as specified and as directed
Supply only calcium based white to off white free flowing solid granuals chemicals having chlorine content of minimum 60% for chlorination in 45 kg packing complete all as specified and as directed
M&L for prepration of surface of water pipe line above the ground level for Pinting with two coats of weather proof synthetic enamaled paint over one coat of primer complete all as specified and as directed
Supply & install in repair testing , commissioning of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed
Taking the water sample for semi under ground sump and submitted the sample of water to the Govt lab for testing of water Qutarly ,Chlorine test and all chemical componants test complete all as specified and as directed
Supply laying, testing GI tubing 80mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing GI tubing 50mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing GI tubing 40mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing GI tubing 25 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing GI tubing 20 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing CPVC pipe (SRD 11) line 20 mm dia bore with all fittings laid in trenches complete all as specified and as directed
Supply laying, testing CPVC pipe (SRD 11) line 25 mm dia bore with all fittings laid in trenches complete all as specified and as directed
.Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose of soil including forming bottom surface to required level and slope complete all as specified and as directed
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 2.5 cm soil complete all as specified and as directed
Removal of surplus soil to a distance not exceeding 50 m and doepositing where directed at a level not exceeding 1.5 m above the strarting point complete all as specified and as directed
Taking down of exixting GI tubing 40/50/80mm bore any type complete all as specified and as directed
Taking down of exixting GI tubing 25mm bore any type complete all as specified and as directed
Taking down of exixting GI tubing 20mm bore any type complete all as specified and as directed
Supply and fix in replacement cast iron flanged drilled heavy duty Non Retrun slucice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers etc of size 80 mm bore complete all as directed by Engr-in-Charge.
Taking out of sluice valve /NRV of size 80/150/100mm/200 mm from existing distribution CI /DI mains all as specified and as directed.
Lifting and taking out the submersible pump set and motor of capacity Upto 12.5 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sump /bore well and lowering back the pump after repairing from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate shall be deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete all as specified and as directed
M&L for repairs & Servicing of defective submersible pump of capacity 10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed . Note:- (a) The rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts will be measured and paid separately under respective item of this schedule.
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed .
Supply and fix parts of submersible pump set of capacity 10 HP complete all as specified and as directed :-
Bearing bush Gun Metal
Bearing bush SS with rubber
Oil seal
Thrust plate/thrust bearing set
Sand Guard
CI Thrust Casing
CI stage casing
GM Bush
Mild steel key for impeller
SS Studs with nuts
CI Intermediate section
SS coupling bush common for pump & motor with key
High Tensile steel shaft
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply ,installation in replacement of starter panel outdoor type with dust and vermin proof compartalized design single front construction ,weld rivet,hinges threads shall be apparent from outside ,powder coated panel IP 52 of size 1375 mmx1050 mmx300 mm including copper busbar of capacity 200 Amp three phase 4 wire and approved manufaturer of LT panels is SMS PANELS & SWITCHGEARS following accessories.
RYB indication Lamps,220V AC- 01 Set
Current Transformer, 60/5A,C1-1.0 - 01 set of three
Phase Sequence- 01No.
On Delay Timer,
OUTGOING SECTION: (i) suitable for 10 to 20 HP S/D STARTER (1W+1S) -02 Nos
MCB 32 A TP 10KA-03 No
Over Load Relay, 14-23A
Star Delta Timer,0-60 Sec
On/Off/Trip Indication Lamps, 220 V AC - 01 set
Start/Stop Push Button,1NO+1NC Make: Vaishno/Teknic
Power Wire, 10 Sqmm Make:KEI/Polycab
Platform of panel:- The platform shall be constructed as per Manufacturer drawing and design.
Supply & fixing in replecement of coloumn pipe made out of GI pipe heavy grade 80 mm nominal bore each 3 meter length including flange duly welded with web complete all as specified and as directed
Supply & Fix in replecement of Bib taps CP
Development of Tube well be means of air compressor unit and then by over pumping unit until sand free water is obtained and testing of yield for duration as under :-
(a) For air compressor unit minimum 100 PSI, 300 CFM for 1 to 24 hrs all as specified and directed.
Rubber floor Mat for sub station use size (24x36 Inch)10mm thick colour back all as specified and as directed by engr in charge.
Supply & Fix in replecement of Angle Valve CP complete all as specified and as directed
Supply & Fix in replecement of Stop Cock CP complete all as specified and as directed
Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 500 KVA,capacity Make : Cummins ( including the cost of the following spares all as per OEM instructions and directed by Engineer in Charge. (Note:- contracter shall submit MOU of OEM cummins with authorised service engineer&Necessary test report shall be submitted)
S & F in repair lubrication oil filter
S & F in repair by pass filter
Checking of hydraulic governer
Chacking and toping up of coolant
S & F in repair fuel filter.
S & F in repair air cleaner element .
Cleaning radiator complete set
Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction
All as per item No 113 (a) to (h) here in before but for up to below 250 KVA DG set Make Cummins complete all as specified
All as per item No 113 (a) to (h) here in before but for up to below up to 380/400 KVA DG set Make cummins complete all as specified
Supply and fixing in replacement of AVR VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 500KVA complete all as specified and as directed
M & L for Disconnected and opening of self starter assemlly 12/24 volt from 500 KVA DG set taking out unserveceable part of self starter and supply and fixing in rplacement of self suitable size as required on site complete all as specified and directed.(Note:- Rate are deemed tobe include all wom out part including gear & winding complete all as specified)
Dismantling of radiator fan engine of following capacity, cleaning and chocked tubes after draining out water, washing with caustic, descaling and brazing for water leakage etc. and refixing the same properly complete all as specified & directed :
up to 500 KVA
Supply only the following items of DG Set of various capacity Complete all as specified and as directed :-
Battery terminal, lug, bolts type suitable for heavy duty battery.
Battery leads for copper conductor multiwired 70 Sqmm. Single Core
Hinges for DG set door of any size, any type as required on site.
S & F in replacement of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use Complete all as specified and as directed
Supply only coolant suitable for generator set diesal engine driven of best quality ISI marked Complete all as specified and as directed
S&F of V belt for fan pulley (set of 2Nos) for DG set upto 500 KVA DG Set complete all as specified.
S&F of V belt for alternator and water pump assembly for DG set upto 500 KVA complete all as specified.
S&F of Fuel hose pipe from fuel filter to fuel pump for DG set upto 500 KVA, complete all as specified.
S&F of Fuel pipe from fuel tank to fuel filter for DG set upto 500 KVA, complete all as specified.
M & L for carriying out complete overhauling /servicing of DG Set panel /AMF panel /control panel,including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor,for DG set of any type/capacity making all electric connections and testing for smooth operation complete all as specified and as directed
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 500 KVA complete all as specified and as directed
Supply and fixing of battery voltage relay 12 VDC complete all as specified and as directed .
Supply and fixing of Fuse (HRC type) for DG sets of capacity up to 500 KVA complete all as specified and as directed
Supply and fixing in replecement of Lead acid maintenance free Battry 12 Volts 120AH of existing type & size suitable for DG Sets . including initial charging complete all as specified and as directed
Supply and fixing in replecement of 63 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as specified and as directed.
Labour for attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc . Note -(i) The cost of replaced spare parts shall be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 100/ per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 250 KVA to 500 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and as directed.
Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 250 KVA to 500 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as directed.
M&L for capacity 250 to 500 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and as directed
M & L for carry out periodical maintenance & servicing (monthly) from authorised rep or service engineer from the manufacturer of blower of STP ( including the cost of replacement of Gear oil , Replacement of worn out helical Gear, worn out blower moter Fan & fan belt etc.) all as per OEM instructions and directed by Engineer in Charge .
Comprehensive maintenance for repair by periodical (monthly) checking of motor compresser system , valve , STP pipe line , fillter system , pressure guage including air compressor complete coupling & leakage joint & repair / replacement of worn out parts of sewage tretment plant as existing complete all as specified and as directed. Note : i. technician shall attend breckdown on as and when Requaired to rectified the defect urgently ii. Defective parts shall be measured & paid separetely
S&F in replacement of fan belt for compressor / flactuator motor any size & any type as per sample complete All as specified & as directed by engr-in-charge
S&F in replacement of Butter fly / Ball Valve 50 mm nominal bore CPVC complete all as specified and as directed
S&F in replacement of Sewage side flow meter as per sample for STP complete all as specified and as directed
S&F in replacement of treated side flow meter as per sample for STP complete all as specified and as directed
S&F in replacement of Dosing Pump as per sample for complete all as specified and as directed
S&F in replacement of pressure gauge / rotometer as per sample for STP complete all as specified and as directed
M&L for repair blower as per sample for STP complete all as specified and as directed
S&F in replacement of chemical injection pipe as per sample complete all as specified and as directed
M&L for Repair , servicing & Maintenance of chemical injection pump with complete serviciable condition including replacement of worn out part complete all as specified and as directed
M&L for taking out / down pump / motor from base / chambber & opening of the motor up to 7.5 HP carefully & removing burnt windding from stator & rewinding with same gauge of supper enamelled copper inssulated wire & suppirior insulating material including warnishing , heating , greacing replacement of worn out bearring , reassembling the same including testing on full load up to entire satisfaction complete all as specified and as directed
M&L for removing burnt windding from stator & rewinding with same gauge of supper enamelled copper wire & suppirior insulating material including warnishing , heating , greacing replacement of worn out bearring , reassembling the same including testing on full load for 3 HP press feed pump up to entire satisfaction complete all as specified and as directed
M&L for taking out & cleaning of BAR screen chember / oil & greace trap / equvalisation tank / MBBR Tank / floculator tank / tube satteler tank / chlorine contact tank / fillter feed tank / treated water tank , dewatering & digging out sluge , mud state & removing sluge to a distance exc. 250m & N exc 500 m & disposed of complete All as specified & directed by engr-in-charge Note :- i. Rate are deemed include for transpotation & labour Charge from STP to low laying areacomplete all as specified and as directed ii. Cleaning of sluge shall be carried out 2 times of with interval of 3 months each cleaning shall be measured as each job
M&L for taking out & cleaning of sluge draing bed of STP any size digging out sluge , mud state & removing sluge to a distance exc. 250m & n exc 500 m & disposed of complete All as specified & directed by engr-in-charge Note :- i. Rate are deemed include for transpotation & labour Charge from STP to low laying area complete all as specified and as directed ii. Cleaning of sluge shall be carried out 2 times of with interval of 3 months each cleaning shall be measured as each job
Supply only Nitrogenous frertiliser conten 46% nitrogen, Biuret % by weight Max 1.5%, in 50 Kg packets complete all as specified and as directed
Supply only diammonium phosphate phosphourus furtiliser contain nitrogen 18 %, phosphorus 46%in 50 kg packets complete all as specified and as directed
Shrikanth Solutions
sheetal engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .