Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹13.4 L+₹97,754 (7.87%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹24.9 L+₹12.4 L (100.1%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹27.2 L+₹14.8 L (118.8%)Rejected-Finance S O KALA RAM C O LALIT AND BROTHERS UTARLAI UTTARLAI VPO UTTARLAI BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Highest | |
| 5 | L5₹27.4 L+₹15.0 L (120.9%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Highest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Nov 2022, 6:00 pmClosed
GE ARMY BARMER
Military Engineer Services, Jalipa Military Station, Garrison Engineer (Army), Barmer, PIN 344001
REPAIR MAINT OF ELECTRICAL WIRING AND REPLACEMENT OF ELECTRICAL FITTINGS FIXTURES OF CEILING FAN EXHAUST FAN DISTRIBUTION BOX SUB MAIN WIRING AND BUILDING SECURITY LIGHT AND SOLAR WATER HEATER OF OTM AT VERIOUS ASCONE NODE AND ZONE B AT JALIPA MIL
2022_MES_549737_2
8668/E8
Open Tender
Civil Works
Item Rate
330 days
GE ARMY BARMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE ARMY BARMER
₹50,000
3 Jan 2023
8 Oct 2022
2 Nov 2022
8 Oct 2022
1 Nov 2022
15 Oct 2022
Amount
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power) etc complete and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs,isolator, etc complete all as specified and as directed ..
Taking down existing unserviceable sub main wirings with PVC conduits / PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and as directed .
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables drawn through and including surface type in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick mild steel sunken boxes of suitable size with 3 mm thick hylem sheet top cover fixed with suitable size of steel screws for mounting switches, sockets, regulators etc complete for one light/fan/bell point controlled by one ,one way switches as specified and directed.complete all as specified and as directed .
All as per item No. 4 above but One light point controlled by 2- way switches, with cables 1.5 sqmm size.complete all as specified and as directed .
All as per item No. 4 above but one 5 Amps 3/5 pin socket outlet on the same board with other switches.
All as per item No.4 above but one 5 Amps 3/5 pin socket outlet on independent board.
All as per item No. 4 above but wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including including 1.6 mm thick mild steel sunken boxes of suitable size with 3 mm thick hylem sheet top cover fixed with suitable size of steel screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches as specified and directed. complete all as specified and as directed .
All as per item No 09 above but one 5 Amps 3/5 pin socket outlet on the same board with other switch.
All as per item No 09 above but one 5 Amps 3/5 pin socket outlet on independent board.
All as per item No. 09 above but wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board.
All as per item No 09 above but wiring in existing conduit / casing caping for one light/fan/bell point controled by one , one way switch 5 Amps .
All as per item No 09 above but wiring in existing conduit / casing caping for one 5 Amps 3/5 pin socket outlet on the same board with other switch.
All as per item No 09 above but wiring in existing conduit / casing caping for one 5 Amps 3/5 pin socket outlet on independent board.
All as per item No. 09 above but wiring in existing conduit / casing caping for wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board.
S&F switch piano, flush button, 5/6 Amps single pole, one way, 230 Volts.complete all as specified and as directed .
S&F Switch piano, flush button, 5/6 Amps, single pole, two way, 230 Volts complete all as specified and as directed .
S&F socket outlet, 3/5 pin, 5 Amps, flush type. complete all as specified and as directed .
S&F switch socket combination, 3/5 pin, 5 Amps, flush type. complete all as specified and as directed .
S&F Switch socket combination multi-purpose 3pin, 15 Amp and 3 pin, 5 Amps complete all as specified and as directed.
S&F Ceiling rose surface bakelite 65x50 mm, two to three terminals.complete all as specified and as directed.
S & F Bell push,flush type,5 Amp. including taking down old complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type 220 Volt on the existing phenolic laminated sheet etc all as specified and as directed.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables drawn through and including Concealed in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick mild steel sunken boxes /Modular Metal flush box of suitable size suitable size for mounting switches, sockets, regulators etc complete for one light/bell point /ceiling fan/ exhaust fan controlled by one ,one way switches as specified and directed.complete all as specified and as directed .
All as per item No. 25 above but one 5 Amps 3/5 pin socket outlet on independent board.
All as per item No. 25 above but one 5 Amps 3/5 pin socket outlet on the same board with other switches.
All as per item No. 25 above but wiring with 4 sqmm copper cable with 4 Sqmm copper cable as continuous earth wire for one 5/6 pin /16 Amps socket out let on independent board.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F Socket 6A/16A - 2/3 pin combined 2 module,r complete all as specified and directed.
S&F modular type fan regulator 120 Watts , 2 module , complete all as specified and directed.
S&F modular type bell push switch , 1 module , complete all as specified and directed.
S & F modular white cover plate with frame, 2 module complete all as specified and as directed.
All as per item No 35 above but 3 module
All as per item No 35 above but 6 module
All as per item No 35 above but 8 module
S & F Buzzer,Ding Dong AC,230 volts,single pole. including taking down old complete all as specified and as directed.
S&F in repair switch piano, flush button, 5/6 Amps single pole, one way, 230 Volts.complete including taking down old all as specified and as directed .
S&F in repair socket outlet, 3/5 pin, 5 Amps, flush type. complete including taking down old all as specified and as directed .
S&F in repair switch socket combination, 3/5 pin, 5 Amps, flush type. complete including taking down old all as specified and as directed .
S&F in repair Switch socket combination multi-purpose 3pin, 15 Amp and 3 pin, 5 Amps complete including taking down old all as specified and as directed.
S&F in repair Ceiling rose surface bakelite 65x50 mm, two to three terminals.complete including taking down old all as specified and as directed.
S & F in repair Bell push,flush type,5 Amp. including taking down old complete all as specified and as directed.
S & F in repair stepped type electronic fan regulator flush type 220 Volt on the existing phenolic laminated sheet etc all as specified and as directed.
S&F in repair modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F in repair modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F in repair modular socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F in repair modular socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed.
S&F in repair modular type fan regulator 120 Watts , 2 module , complete all as specified and directed.
S&F in repair modular type bell push switch , 1 module , complete all as specified and directed.
S & F in repair modular white cover plate with frame, 2 module complete all as specified and as directed.
All as per item No 53 above but 3 module
All as per item No 53 above but 6 module
All as per item No 53 above but 8 module
S & F in repair buzzer,Ding Dong AC,230 volts,single pole. including taking down old complete all as specified and as directed.
M & L in repair for LED light fitting,1x10 watt bulk head luminaries,,6500k CCT etc.complete with all accessories complete all as specified and directed
S & F LED batten suitble for indoor application 20 W, 4' length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make : Havells/Bajaj/Wipro/Crompton
S & F LED batten suitble for indoor application 10 W, 2' length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make : Havells/Bajaj/Wipro/Crompton
Supply and fix in replacement LED Tube Rod ( integrated Driver),6500K cplour temp, 4 feet long of 20 watt (PC) in existing tube light fitting complete all as specified and directed by Enginner in charge of Make - Crompton/ Havells/ Philips/Bajaj/Wipro
Supply and fix in replacement recess mounted low glare LED panellight 2'X2' size 36 watt white/warm white for armstrong/grid ceiling or similar ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade complete all as specified and directed. Make: BAJAJ/Wipro/Crompton/Havells
Supply and fix in replacement recess mounted low glare LED panellight 1'X4' size 36 watt white/warm white for armstrong/grid ceiling or POP ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade complete all as specified and directed. Make: BAJAJ/Wipro/Crompton/Havells
S & F in repair Lamp holder insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repair 5/6 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powdercoating with efficacy 100 lumen/watt round/square type as per site conditions warm white/white complete all as specified and directed. Make - Crompton/ Havells/ Philips/Bajaj/Wipro
S&F in repair 12 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powdercoating with efficacy 100 lumen/watt round/square type as per site conditions warm white/white complete all as specified and directed. Make - Crompton/ Havells/ Philips/Bajaj/Wipro
S & F in repair 15 watt LED Downlight flat down light back lit, recess mouting round/square type as per site conditions warm white/white complete with all attachment all as specified and directed Make - Crompton/ Havells/ Philips/Bajaj/Wipro
S & F in repair 18 watt LED Downlight flat down light back lit, recess mouting round/square type as per site conditions warm white/white complete with all attachment all as specified and directed Make - Crompton/ Havells/ Philips/Bajaj/Wipro
S & F in repair LED 25 Watt street light fitting for bldg secutiry complete with light grade GI brackets, Nuts, bolts, clamps complete with all accessories internaly pre wired and including connecting up with twin core twisted flexible copper conductor cable complete as specified and as directed by Engineer in charge Make - Crompton/ Havells/ Philips/Bajaj/Wipro.
S&F in repair PVC rectangular block of size 10cm x 10cm x 5 cm depth for mounting switches sockets, fan regulators etc with 3 mm thick laminated sheet cover including taking down old one complete all as specified and as directed .
S&F in repair PVC board of size 17.5cm x 10cm x 5 cm depth for mounting switches sockets, fan regulators etc with 3 mm thick laminated sheet cover including taking down old one complete all as specified and as directed .
S&F in repair PVC board of size 20cm x 15cm x 5 cm depth for mounting switches sockets, fan regulators etc with 3 mm thick laminated sheet cover including taking down old one complete all as specified and as directed .
S&F in repair PVC board of size 25cm x 20cm x 5 cm depth for mounting switches sockets, fan regulators etc with 3 mm thick laminated sheet cover including taking down old one complete all as specified and as directed .
S&F in repair PVC board of size 35 cm x 30 cm x 5cm depth for mounting switches sockets, fan regulators etc with 3 mm thick laminated sheet cover including taking down old one complete all as specified and as directed .
S & F in replacement hylum sheet 3mm thick top cover of size 30cm x 25cm x 3mm including taking down old complete all as specified and as directed .
S & F in replacement hylum sheet 3mm thick top cover of size 25cm x 20cm x 3mm including taking down old complete all as specified and as directed .
S & F in replacement hylum sheet 3mm thick top cover of size 20cm x 15cm x 3mm including taking down old complete all as specified and as directed .
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC casing and capping with all necessary accessories will be measured as one length).
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC casing and capping with all necessary accessories will be measured as one length).
M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC casing and capping with all necessary accessories will be measured as one length).
M&L sub main wiring surface type/ concealed type as required at site with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L sub main wiring surface type/conealed type as required at site with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
S&F in repair factory made board distribution in sheet steel enclosure without bus bar SPN, 2 way, 240 Volts suitable for fixing MCBs.complete all as specified and as directed .
S&F in repair Factory made board distribution in sheet steel enclosure with 200 Amps rated bus bar SPN, 4 way double door 240 Volts suitable for fixing MCBs.complete all as specified and as directed .
S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 8 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, TPN 4 way with 200 Amps rated bus bar , 415 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately
M&L for taking down old unserviceable MCCB TP/TPN from existing LT panel board and supply and fix MCCB TPN 100 amps capacity, 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed.replacement of brunt lugs and wire/cable pieces etc as required at site.
S&F/S&F in repair MCB, SP, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete all as specified and as directed
S&F MCB, SPN, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed
S&F/S&F in repair MCB, SPN, 240 Volts, 40 to 63 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed
S&F MCB, TPN, 415 Volts, 16 to 32 Amps., 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral in the MCB DB complete all as specified and as directed
S&F/S&F in repair MCB, TPN, 415 Volts, 40 to 100 Amps., 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral in the MCB DB complete all as specified and as directed
S&F Blanking plate for filling gap of MCB.complete all as specified and as directed .
Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 20 A ,240 V complete all as specified and as directed.
Taking down ceiling fan/ Wall mounting fan of any size and sweep from its position and dismantling for servicing including removal of bearing, bushes, condenser, connector, flexible cord,split pin etc if required, removing old grease and refill fresh, lubricating bushes alongwith new washers, cleaning and washing fan blades & fan body with soap solution after repairing and re- assamble the same including provision of twisted twin core flexible wire upto 0.7m long of size 28/0.0076 (ISI marked) and connecting to electric system, testing etc and hanging in position / to any location at Jalipa Stn complete all as specified and as directed . Note: -(i) Spare parts shall be measured and paid separately as supply only. (ii) Quoted rate is deemed to be inclusive of taking down unserviceable/ defective parts and fixing with new parts. (iii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store yard.
All as per item No 97 above but for Exhaust fan of any size and make.
M&L for Spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and as directed.
Supply only U clamp complete with nut bolt washer, split pin and rubber weal etc complete all as specified and directed by engineer in charge.
M&L for Cutting and taking out old burnout winding of any sweep ceiling fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed .
M&L for Cutting and taking out old burnout winding of 300 mm sweep exhaust fan / wall fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed .
All as per item No 102 above but for 380/450 mm sweep complete all as specified and as directed .
M&L for Spray painting of exhaust fan of any size and make with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and as directed.
Supply only ball bearing suitable for ceiling fan / exhaust fan of any sweep complete all as specified and as directed .
Supply only gun metal bush suitable for exhaust fan of any sweep complete all as specified and as directed .
Supply only condensor 2.5 MFD suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motorcomplete including connecting with 3 core flexible copper conductor including taking down the existing ceiling fan and depositing the same in MES store complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete including connecting with 3 core flexible copper conductor including taking down the existing exhaust fan and depositing the same in MES store complete all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm complete including connecting with 3 core flexible copper conductor including taking down the existing exhaust fan and depositing the same in MES store complete all as specified and as directed.
M&L for Submersible pump of discharge head 2.5 Mtr 220-240 volts AC supply single phase 40 watt including taking down old pump complete all as specified and as directed.
Supply only condensor 4 MFD suitable for ceiling fan of any sweep complete all as specified and as directed.
M&L for Wood / wool chips pad for Desert Cooler of size 600 x 550 x 30mm (set of three pads) superior quality complete all as specified and directed including taking down old pads complete all as specified and as directed.
M&L for supporting jali to wood / wool chips pad set made out of hard MS wire and fitted inside louvers (set of three) complete all as specified and directed including taking down old jali complete all as specified and as directed.
M&L for PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area (superior quality) including taking down old cable complete all as specified and as directed.
M&L for PVC water distributor of 3 out lets with MS nuts & bolts including taking down old one complete all as specified and as directed.
M&L for PVC elbow suitable for desert cooler including taking down old elbow complete all as specified and as directed.
M&L for PVC pipe 15mm dia heavy duty for Desert Cooler Pump including taking down old pipe complete all as specified and as directed.
M&L for Plug top 3 pin of capacity 5 Amp AC 240 Volts 50 Hz including taking down old plug top complete all as specified and as directed.
M&L for Motor fixing ring with eight screw (clip type) for desert cooler including taking down old one complete all as specified and as directed.
M&L for Spray painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel paint over one coat of red oxide primer on external surface and two coats of anti-corrosive black paint over a coat of red oxide primer on inside the body tank and side grills including scraping / rubbing with wire brush on old surface of Desert cooler and writing MES No. etc complete all as specified and directed.
Comprehensive maintenance and repairs of Solar Water Heating System consisting of Solar Water Heater Tank with Stand, Flat Plate Collector (Copper based), Electircal Coil (for backup), Non Return Valve at Inlet and Outlet, Pressure Release Valve etc complete of 10 Nos of 200 LPD capacities with electric back up. complete all as specified and as directed. Note: (i) Cost of any minor spares shall be deemed to be included in the quoted rate (ii) Spares such as heating element, thermostat, pressure release valve, non return valves will be measured and paid in relevant items as supply only.
Supply only Heating element 2000 W round type as per existing make & model complete all as per specified and directed .
S&F thermostat for 25/50 Ltr cap of geyser as per existing make & model complete all as per specified and directed .
S&F pressure release valve, safety valve ISI maked for any type/capacity of geyser and making connection as per existing make & model suitable for geyser of any type/capacity complete all as per specified and directed .
S&F non-return valve ISI marked, chromium plated, in suction line of geyser and making connection as per existing make & model complete all as per specified and directed .
Devi Engineeing
M/s Malinath Electricals
Lalit and Brothers
M/S TANUSHREE CONSTRUCTION COMPANY
m/s jogaram sujaram
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .